Are immediate postoperative X-Rays valuable in evaluating complications of primary total hip arthroplasty?

IF 4.6 Q2 MATERIALS SCIENCE, BIOMATERIALS
Matthew L Brown, David Michel, Arvind Narayanan, Julie C McCauley, William D Bugbee
{"title":"Are immediate postoperative X-Rays valuable in evaluating complications of primary total hip arthroplasty?","authors":"Matthew L Brown,&nbsp;David Michel,&nbsp;Arvind Narayanan,&nbsp;Julie C McCauley,&nbsp;William D Bugbee","doi":"10.1186/s42836-022-00148-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to investigate the complications of primary total hip arthroplasty based on immediate postoperative X-rays. The overall quality and cost of X-rays were assessed.</p><p><strong>Methods: </strong>The institutional database was queried to identify all patients who underwent total hip arthroplasty in a single institution between January 1, 2018, and December 31, 2018. Immediate postoperative X-rays were reviewed to identify the complications such as periprosthetic fractures, dislocation, and fixation failure. The quality and cost of X-ray were assessed. The complications were categorized as \"known\" and \"unknown\" according to the intraoperative fluoroscopic results.</p><p><strong>Results: </strong>A total of 518 total hip arthroplasties were included in this study. Based on intraoperative fluoroscopy, periprosthetic fractures were found in 10 (2%) THAs. Compared to the X-rays taken immediately after surgery, 9 periprosthetic fractures (recorded as \"known\") were found and 1 was not (recorded as \"unknown\"). There was no significant difference between intraoperative fluoroscopy and X-rays (P > 0.05). Of the 518 X-rays, 225 (43%) were of suboptimal quality. The cost of a single portable pelvic X-ray was $647.</p><p><strong>Conclusion: </strong>In total hip arthroplasty, X-rays taken immediately after surgery rarely reveal unknown complications. The X-rays are often of suboptimal quality, have minimal clinical utility, and are less cost-effective.</p>","PeriodicalId":2,"journal":{"name":"ACS Applied Bio Materials","volume":null,"pages":null},"PeriodicalIF":4.6000,"publicationDate":"2022-11-02","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9628056/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Bio Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s42836-022-00148-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This study aimed to investigate the complications of primary total hip arthroplasty based on immediate postoperative X-rays. The overall quality and cost of X-rays were assessed.

Methods: The institutional database was queried to identify all patients who underwent total hip arthroplasty in a single institution between January 1, 2018, and December 31, 2018. Immediate postoperative X-rays were reviewed to identify the complications such as periprosthetic fractures, dislocation, and fixation failure. The quality and cost of X-ray were assessed. The complications were categorized as "known" and "unknown" according to the intraoperative fluoroscopic results.

Results: A total of 518 total hip arthroplasties were included in this study. Based on intraoperative fluoroscopy, periprosthetic fractures were found in 10 (2%) THAs. Compared to the X-rays taken immediately after surgery, 9 periprosthetic fractures (recorded as "known") were found and 1 was not (recorded as "unknown"). There was no significant difference between intraoperative fluoroscopy and X-rays (P > 0.05). Of the 518 X-rays, 225 (43%) were of suboptimal quality. The cost of a single portable pelvic X-ray was $647.

Conclusion: In total hip arthroplasty, X-rays taken immediately after surgery rarely reveal unknown complications. The X-rays are often of suboptimal quality, have minimal clinical utility, and are less cost-effective.

Abstract Image

术后即刻x光片在评估原发性全髋关节置换术并发症中有价值吗?
目的:探讨原发性全髋关节置换术术后即刻x线的并发症。评估了x射线的整体质量和成本。方法:查询机构数据库,以确定2018年1月1日至2018年12月31日期间在单一机构接受全髋关节置换术的所有患者。术后立即x线检查确定并发症,如假体周围骨折、脱位和固定失败。评估x射线的质量和成本。根据术中透视结果将并发症分为“已知”和“未知”两类。结果:本研究共纳入518例全髋关节置换术。术中透视显示,10例(2%)tha发生假体周围骨折。与术后立即拍摄的x光片相比,发现假体周围骨折9例(记录为“已知”),未发现骨折1例(记录为“未知”)。术中x线检查与x线检查差异无统计学意义(P > 0.05)。在518张x射线中,225张(43%)质量不佳。一次便携式骨盆x光检查的费用是647美元。结论:在全髋关节置换术中,术后立即行x线检查很少发现未知的并发症。x光片的质量通常不理想,临床效用最小,成本效益也较低。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Applied Bio Materials
ACS Applied Bio Materials Chemistry-Chemistry (all)
CiteScore
9.40
自引率
2.10%
发文量
464
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信