Evaluation of morphological features: femtosecond-LASIK flap vs. SMILE cap, and the effects on corneal higher-order aberrations.

Xiaoying He, Qin He, Minjie Yuan, Zhi Fang, Kai Zhang, Tiepei Zhu, Wei Han
{"title":"Evaluation of morphological features: femtosecond-LASIK flap vs. SMILE cap, and the effects on corneal higher-order aberrations.","authors":"Xiaoying He,&nbsp;Qin He,&nbsp;Minjie Yuan,&nbsp;Zhi Fang,&nbsp;Kai Zhang,&nbsp;Tiepei Zhu,&nbsp;Wei Han","doi":"10.1007/s00417-022-05841-0","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study is to evaluate morphological features of corneal flap/cap and the correlations with corneal higher-order aberrations (HOAs) changes after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE).</p><p><strong>Methods: </strong>This was a retrospective study. Pre- and postoperative (1 and 3 months) corneal HOAs were assessed with Pentacam HR. The corneal flap/cap thickness at 32 points (± 1.5 mm, ± 2 mm, ± 2.5 mm, and ± 3 mm from the corneal vertex on meridian 0°/45°/90°/135°) were measured using anterior segment optical coherence tomography at 3 months postoperatively. Morphological features of corneal flap/cap including predictability (P), uniformity (U), and symmetry (S) were calculated and used for correlation analysis with corneal HOAs changes.</p><p><strong>Results: </strong>Eighty-six eyes (44 patients) and ninety-six eyes (50 patients) were involved in FS-LASIK and SMILE groups, respectively. Significant thicker corneal flap/cap than the predicted was observed at each measuring point and meridian in both groups (difference > 2.225 μm, the within-subject standard deviation over 6-mm optical zone). There was no statistically significant difference in predictability of corneal flap/cap thickness, while U<sub>6 mm</sub> (P < .0001), U<sub>0</sub> (P < .001), U<sub>45</sub> (P = .002), U<sub>90</sub> (P < .0001), U<sub>135</sub> (P = .004), S<sub>6 mm</sub> (P < .0001), S<sub>0</sub> (P < .001), and S<sub>90</sub> (P < .0001) over 6 mm zone were less in SMILE than in FS-LASIK. The changes of corneal tHOAs, Z (3, - 1), Z (3, 1), and SA were significantly correlated with morphological features of corneal flap/cap.</p><p><strong>Conclusion: </strong>Both FS-LASIK and SMILE had good predictability in flap or cap thickness, while the uniformity and symmetry of SMILE cap were better than FS-LASIK flap. The quality of flap/cap was closely associated with the changes of corneal HOAs.</p>","PeriodicalId":520634,"journal":{"name":"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie","volume":" ","pages":"3993-4003"},"PeriodicalIF":0.0000,"publicationDate":"2022-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00417-022-05841-0","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/9/27 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The aim of this study is to evaluate morphological features of corneal flap/cap and the correlations with corneal higher-order aberrations (HOAs) changes after femtosecond laser in situ keratomileusis (FS-LASIK) and small incision lenticule extraction (SMILE).

Methods: This was a retrospective study. Pre- and postoperative (1 and 3 months) corneal HOAs were assessed with Pentacam HR. The corneal flap/cap thickness at 32 points (± 1.5 mm, ± 2 mm, ± 2.5 mm, and ± 3 mm from the corneal vertex on meridian 0°/45°/90°/135°) were measured using anterior segment optical coherence tomography at 3 months postoperatively. Morphological features of corneal flap/cap including predictability (P), uniformity (U), and symmetry (S) were calculated and used for correlation analysis with corneal HOAs changes.

Results: Eighty-six eyes (44 patients) and ninety-six eyes (50 patients) were involved in FS-LASIK and SMILE groups, respectively. Significant thicker corneal flap/cap than the predicted was observed at each measuring point and meridian in both groups (difference > 2.225 μm, the within-subject standard deviation over 6-mm optical zone). There was no statistically significant difference in predictability of corneal flap/cap thickness, while U6 mm (P < .0001), U0 (P < .001), U45 (P = .002), U90 (P < .0001), U135 (P = .004), S6 mm (P < .0001), S0 (P < .001), and S90 (P < .0001) over 6 mm zone were less in SMILE than in FS-LASIK. The changes of corneal tHOAs, Z (3, - 1), Z (3, 1), and SA were significantly correlated with morphological features of corneal flap/cap.

Conclusion: Both FS-LASIK and SMILE had good predictability in flap or cap thickness, while the uniformity and symmetry of SMILE cap were better than FS-LASIK flap. The quality of flap/cap was closely associated with the changes of corneal HOAs.

形态学特征的评价:飞秒lasik皮瓣与SMILE帽,以及对角膜高阶像差的影响。
目的:探讨飞秒激光原位角膜磨除术(FS-LASIK)和小切口晶状体摘除术(SMILE)术后角膜瓣/帽的形态学特征及其与角膜高阶像差(HOAs)变化的相关性。方法:回顾性研究。术前和术后(1个月和3个月)用Pentacam HR评估角膜hoa。术后3个月采用前段光学相干断层扫描测量角膜顶点距经络0°/45°/90°/135°处32点(±1.5 mm、±2mm、±2.5 mm、±3mm)角膜瓣/帽厚度。计算角膜瓣/帽的形态学特征,包括可预测性(P)、均匀性(U)和对称性(S),并将其与角膜HOAs变化进行相关性分析。结果:FS-LASIK组86只眼(44例),SMILE组96只眼(50例)。两组各测点及经络处角膜瓣/帽厚度均显著高于预测值(差异> 2.225 μm,受试者内标准差大于6 mm光学区)。角膜瓣/角膜帽厚度的可预测性差异无统计学意义,U6 mm (P = 0.45 (P = 0.002))、U90 (P = 0.135 (P = 0.004)、S6 mm (P = 0.90 (P))结论:FS-LASIK和SMILE角膜瓣或角膜帽厚度的可预测性均较好,SMILE角膜帽的均匀性和对称性优于FS-LASIK角膜瓣。皮瓣/帽的质量与角膜hoa的变化密切相关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信