Effects of ROI Placement on PET-Based Assessment of Tumor Response to Therapy.

International journal of molecular imaging Pub Date : 2013-01-01 Epub Date: 2013-03-07 DOI:10.1155/2013/132804
Mike Sattarivand, Curtis Caldwell, Ian Poon, Hany Soliman, Katherine Mah
{"title":"Effects of ROI Placement on PET-Based Assessment of Tumor Response to Therapy.","authors":"Mike Sattarivand,&nbsp;Curtis Caldwell,&nbsp;Ian Poon,&nbsp;Hany Soliman,&nbsp;Katherine Mah","doi":"10.1155/2013/132804","DOIUrl":null,"url":null,"abstract":"<p><p>Purpose. Quantitative PET response assessment during therapy requires regions of interest (ROI). Commonly, a fixed-size ROI is placed at the maximum uptake point in the pretreatment study. For intratreatment, the ROI is placed either at the maximum uptake point (ROIpeak) or at the same location as the pretreatment ROI (ROIsame). We have evaluated the effects of the ROI placement on response assessment. Methods. PET scans of 15 head and neck cancer patients were used to evaluate the effects of the two ROI methods on response assessment. Results. The average intratreatment ROIpeak uptake was 13.4% higher than the ROIsame uptake (range -14% to 38%). The average relative change in ROIpeak uptake was 7.9% lower than ROIsame uptake (range -5% to 36%), resulting in ambiguous tumour classification in 19% of the tumours. Conclusion. Quantitative PET response assessment using a fixed-size ROI is sensitive the ROI placement. The difference between ROIpeak and ROIsame could be substantial resulting in ambiguous response assessment. Although the fixed-size ROI is simple to implement, it is also prone to the limitations and should be used with caution. Clinical trial data are necessary to establish reliable thresholds for fixed-size ROI techniques and to evaluate their efficacy for response assessment.</p>","PeriodicalId":89157,"journal":{"name":"International journal of molecular imaging","volume":" ","pages":"132804"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2013/132804","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/132804","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/3/7 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Purpose. Quantitative PET response assessment during therapy requires regions of interest (ROI). Commonly, a fixed-size ROI is placed at the maximum uptake point in the pretreatment study. For intratreatment, the ROI is placed either at the maximum uptake point (ROIpeak) or at the same location as the pretreatment ROI (ROIsame). We have evaluated the effects of the ROI placement on response assessment. Methods. PET scans of 15 head and neck cancer patients were used to evaluate the effects of the two ROI methods on response assessment. Results. The average intratreatment ROIpeak uptake was 13.4% higher than the ROIsame uptake (range -14% to 38%). The average relative change in ROIpeak uptake was 7.9% lower than ROIsame uptake (range -5% to 36%), resulting in ambiguous tumour classification in 19% of the tumours. Conclusion. Quantitative PET response assessment using a fixed-size ROI is sensitive the ROI placement. The difference between ROIpeak and ROIsame could be substantial resulting in ambiguous response assessment. Although the fixed-size ROI is simple to implement, it is also prone to the limitations and should be used with caution. Clinical trial data are necessary to establish reliable thresholds for fixed-size ROI techniques and to evaluate their efficacy for response assessment.

Abstract Image

Abstract Image

Abstract Image

ROI放置对基于pet的肿瘤治疗反应评估的影响。
目的。治疗期间定量PET反应评估需要感兴趣区域(ROI)。通常,在预处理研究中,固定大小的ROI被放置在最大摄取点。对于内部处理,ROI被放置在最大摄取点(ROIpeak)或与预处理ROI (ROIsame)相同的位置。我们已经评估了ROI放置对响应评估的影响。方法。采用15例头颈癌患者的PET扫描,评价两种ROI方法对疗效评估的影响。结果。平均治疗内ROIpeak摄取量比ROIsame摄取量高13.4%(范围为-14%至38%)。ROIpeak摄取的平均相对变化比ROIsame摄取低7.9%(范围为-5%至36%),导致19%的肿瘤分类不明确。结论。使用固定大小的ROI进行定量PET响应评估对ROI的位置很敏感。ROIpeak和ROIsame之间的差异可能会导致模棱两可的反应评估。虽然固定大小的ROI很容易实现,但它也容易受到限制,应该谨慎使用。临床试验数据是必要的,以建立可靠的阈值固定大小的ROI技术和评估其疗效的反应评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书