Feasibility evaluation of radioimmunoguided surgery of breast cancer.

International journal of molecular imaging Pub Date : 2012-01-01 Epub Date: 2012-02-20 DOI:10.1155/2012/545034
Ananth Ravi, Raymond M Reilly, Claire M B Holloway, Curtis B Caldwell
{"title":"Feasibility evaluation of radioimmunoguided surgery of breast cancer.","authors":"Ananth Ravi,&nbsp;Raymond M Reilly,&nbsp;Claire M B Holloway,&nbsp;Curtis B Caldwell","doi":"10.1155/2012/545034","DOIUrl":null,"url":null,"abstract":"<p><p>Breast-conserving surgery involves completely excising the tumour while limiting the amount of normal tissue removed, which is technically challenging to achieve, especially given the limited intraoperative guidance available to the surgeon. This study evaluates the feasibility of radioimmunoguided surgery (RIGS) to guide the detection and delineation of tumours intraoperatively. The 3D point-response function of a commercial gamma-ray-detecting probe (GDP) was determined as a function of radionuclide ((131)I, (111)In,( 99m)Tc), energy-window threshold, and collimator length (0.0-3.0-cm). This function was used to calculate the minimum detectable tumour volumes (MDTVs) and the minimum tumour-to-background activity concentration ratio (T:B) for effective delineation of a breast tumour model. The GDP had larger MDTVs and a higher minimum required T:B for tumour delineation with (131)I than with (111)In or (99m)Tc. It was shown that for (111)In there was a benefit to using a collimator length of 0.5-cm. For the model used, the minimum required T:B required for effective tumour delineation was 5.2 ± 0.4. RIGS has the potential to significantly improve the accuracy of breast-conserving surgery; however, before these benefits can be realized, novel radiopharmaceuticals need to be developed that have a higher specificity for cancerous tissue in vivo than what is currently available.</p>","PeriodicalId":89157,"journal":{"name":"International journal of molecular imaging","volume":" ","pages":"545034"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2012/545034","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2012/545034","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/2/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Breast-conserving surgery involves completely excising the tumour while limiting the amount of normal tissue removed, which is technically challenging to achieve, especially given the limited intraoperative guidance available to the surgeon. This study evaluates the feasibility of radioimmunoguided surgery (RIGS) to guide the detection and delineation of tumours intraoperatively. The 3D point-response function of a commercial gamma-ray-detecting probe (GDP) was determined as a function of radionuclide ((131)I, (111)In,( 99m)Tc), energy-window threshold, and collimator length (0.0-3.0-cm). This function was used to calculate the minimum detectable tumour volumes (MDTVs) and the minimum tumour-to-background activity concentration ratio (T:B) for effective delineation of a breast tumour model. The GDP had larger MDTVs and a higher minimum required T:B for tumour delineation with (131)I than with (111)In or (99m)Tc. It was shown that for (111)In there was a benefit to using a collimator length of 0.5-cm. For the model used, the minimum required T:B required for effective tumour delineation was 5.2 ± 0.4. RIGS has the potential to significantly improve the accuracy of breast-conserving surgery; however, before these benefits can be realized, novel radiopharmaceuticals need to be developed that have a higher specificity for cancerous tissue in vivo than what is currently available.

Abstract Image

Abstract Image

Abstract Image

放射免疫引导乳腺癌手术的可行性评价。
保乳手术包括完全切除肿瘤,同时限制正常组织的切除量,这在技术上是具有挑战性的,特别是考虑到外科医生可以获得的有限术中指导。本研究评估放射免疫引导手术(RIGS)指导术中肿瘤检测和描绘的可行性。利用放射性核素((131)I, (111)In,(99m)Tc)、能量窗阈值和准直器长度(0.0-3.0 cm)确定了商用伽马射线探测探头(GDP)的三维点响应函数。该函数用于计算最小可检测肿瘤体积(mdtv)和最小肿瘤与背景活性浓度比(T:B),以有效描绘乳腺肿瘤模型。与(111)In或(99m)Tc相比,(131)I的GDP具有更大的mdtv和更高的肿瘤划定所需的最小T:B。结果表明,对于(111)In,使用长度为0.5 cm的准直器是有利的。对于所使用的模型,有效肿瘤描绘所需的最小T:B为5.2±0.4。RIGS具有显著提高保乳手术准确性的潜力;然而,在实现这些益处之前,需要开发出对体内癌组织具有比现有药物更高特异性的新型放射性药物。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书