Twin-Wire Networks for Zero Interconnect, High-Density 4-Wire Electrical Characterizations of Materials.

IF 10.7
Research (Washington, D.C.) Pub Date : 2022-01-11 eCollection Date: 2022-01-01 DOI:10.34133/2022/9874249
Nerio Andrés Montoya, Valeria Criscuolo, Andrea Lo Presti, Raffaele Vecchione, Christian Falconi
{"title":"Twin-Wire Networks for Zero Interconnect, High-Density 4-Wire Electrical Characterizations of Materials.","authors":"Nerio Andrés Montoya,&nbsp;Valeria Criscuolo,&nbsp;Andrea Lo Presti,&nbsp;Raffaele Vecchione,&nbsp;Christian Falconi","doi":"10.34133/2022/9874249","DOIUrl":null,"url":null,"abstract":"<p><p>Four-wire measurements have been introduced by Lord Kelvin in 1861 and have since become the standard technique for characterizing small resistances and impedances. However, high-density 4-wire measurements are generally complex, time-consuming, and inefficient because of constraints on interconnects, pads, external wires, and mechanical contacts, thus reducing reproducibility, statistical significance, and throughput. Here, we introduce, systematically design, analyze, and experimentally validate zero interconnect networks interfaced to external instrumentation by couples of twin wire. 3D-printed holders with magnets, interconnects, nonadhesive layers, and spacers can effortlessly establish excellent electrical connections with tunable or minimum contact forces and enable accurate measurements even for delicate devices, such as thin metals on soft polymers. As an example, we measured all the resistances of a twin-wire 29-resistor network made of silver-nanoparticle ink printed on polyimide, paper, or photo paper, including during sintering or temperature calibration, resulting in an unprecedentedly easy and accurate characterization of both resistivity and its temperature coefficient. The theoretical framework and experimental strategies reported here represent a breakthrough toward zero interconnect, simple, and efficient high-density 4-wire characterizations, can be generalized to other 4-wire measurements (impedances, sensors) and can open the way to more statistically meaningful and reproducible analyses of materials, high-throughput measurements, and minimally invasive characterizations of biomaterials.</p>","PeriodicalId":520765,"journal":{"name":"Research (Washington, D.C.)","volume":" ","pages":"9874249"},"PeriodicalIF":10.7000,"publicationDate":"2022-01-11","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8771198/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Research (Washington, D.C.)","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.34133/2022/9874249","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Four-wire measurements have been introduced by Lord Kelvin in 1861 and have since become the standard technique for characterizing small resistances and impedances. However, high-density 4-wire measurements are generally complex, time-consuming, and inefficient because of constraints on interconnects, pads, external wires, and mechanical contacts, thus reducing reproducibility, statistical significance, and throughput. Here, we introduce, systematically design, analyze, and experimentally validate zero interconnect networks interfaced to external instrumentation by couples of twin wire. 3D-printed holders with magnets, interconnects, nonadhesive layers, and spacers can effortlessly establish excellent electrical connections with tunable or minimum contact forces and enable accurate measurements even for delicate devices, such as thin metals on soft polymers. As an example, we measured all the resistances of a twin-wire 29-resistor network made of silver-nanoparticle ink printed on polyimide, paper, or photo paper, including during sintering or temperature calibration, resulting in an unprecedentedly easy and accurate characterization of both resistivity and its temperature coefficient. The theoretical framework and experimental strategies reported here represent a breakthrough toward zero interconnect, simple, and efficient high-density 4-wire characterizations, can be generalized to other 4-wire measurements (impedances, sensors) and can open the way to more statistically meaningful and reproducible analyses of materials, high-throughput measurements, and minimally invasive characterizations of biomaterials.

Abstract Image

Abstract Image

Abstract Image

用于零互连的双线网络,高密度4线材料的电气特性。
开尔文勋爵(Lord Kelvin)于1861年引入了四线测量方法,从此成为表征小电阻和小阻抗的标准技术。然而,高密度4线测量通常是复杂、耗时和低效的,因为互连、焊盘、外部导线和机械触点的限制,从而降低了再现性、统计显著性和吞吐量。在这里,我们介绍,系统地设计,分析,并实验验证了零互连网络通过双线对连接到外部仪器。带有磁铁、互连、非粘性层和垫片的3d打印支架可以毫不费力地建立良好的电气连接,具有可调或最小的接触力,甚至可以对精密设备(如软聚合物上的薄金属)进行精确测量。作为一个例子,我们测量了在聚酰亚胺、纸张或相纸上印刷的银纳米颗粒油墨制成的双线29电阻网络的所有电阻,包括烧结或温度校准期间的电阻,从而实现了前所未有的简单和准确的电阻率及其温度系数表征。本文报道的理论框架和实验策略代表了零互连,简单,高效的高密度4线表征的突破,可以推广到其他4线测量(阻抗,传感器),并可以为更具统计意义和可重复性的材料分析,高通量测量和生物材料的微创表征开辟道路。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书