{"title":"Simple monitoring of pH and urea in whole blood using wearable smart woman pad.","authors":"Bambang Kuswandi,&nbsp;Nur Andriani,&nbsp;Ari S Nugraha","doi":"10.34172/bi.2021.41","DOIUrl":null,"url":null,"abstract":"<p><p><i><b>Introduction:</b></i> In this work, we used a thread-paper microfluidic device (μTPAD) system, where a threaded part for the handling of the whole blood samples and a paper part for the reaction of plasma with immobilized bioreagents integrated into woman pad as a wearable sensing device namely as smart women pad. The μTPAD as a wearable smart woman pad is developed for the detection of pH and urea in mensuration blood as real samples. <i><b>Methods:</b></i> This combined device was constructed to cover the elements required, that is, separation of red blood cell, conditioning, analyte reaction, and colorimetric detection. The color change in sensing areas was measured in the RGB values via a smartphone using the Color Grab after a smart woman pad was used. The thread allowed red blood cell sampling and separation, while the paper microfluidic device was used for conditioning, biorecognition, and colorimetric transduction of pH and urea as analytes. <i><b>Results:</b></i> The time needed for analysis was measured as 110 s using the equilibrium method for both analytes, with a limit of detection (LOD) of 72.55 μg/mL for urea, with precision around 1.68%, while for pH around 0.80%. The smart woman pad allowed rapid detection of pH and urea in menstruation blood as real samples for monitoring of the kidney functions, and the results showed an agreement with the conventional methods that have been generally used in the clinical laboratory. <i><b>Conclusion:</b></i> The smart woman pad has the potential to be used as a wearable device to monitor the health status of the user via its blood mensuration analysis.</p>","PeriodicalId":375065,"journal":{"name":"BioImpacts : BI","volume":" ","pages":"43-50"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a4/cd/bi-12-43.PMC8783083.pdf","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BioImpacts : BI","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.34172/bi.2021.41","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/8/15 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

Introduction: In this work, we used a thread-paper microfluidic device (μTPAD) system, where a threaded part for the handling of the whole blood samples and a paper part for the reaction of plasma with immobilized bioreagents integrated into woman pad as a wearable sensing device namely as smart women pad. The μTPAD as a wearable smart woman pad is developed for the detection of pH and urea in mensuration blood as real samples. Methods: This combined device was constructed to cover the elements required, that is, separation of red blood cell, conditioning, analyte reaction, and colorimetric detection. The color change in sensing areas was measured in the RGB values via a smartphone using the Color Grab after a smart woman pad was used. The thread allowed red blood cell sampling and separation, while the paper microfluidic device was used for conditioning, biorecognition, and colorimetric transduction of pH and urea as analytes. Results: The time needed for analysis was measured as 110 s using the equilibrium method for both analytes, with a limit of detection (LOD) of 72.55 μg/mL for urea, with precision around 1.68%, while for pH around 0.80%. The smart woman pad allowed rapid detection of pH and urea in menstruation blood as real samples for monitoring of the kidney functions, and the results showed an agreement with the conventional methods that have been generally used in the clinical laboratory. Conclusion: The smart woman pad has the potential to be used as a wearable device to monitor the health status of the user via its blood mensuration analysis.

Abstract Image

Abstract Image

Abstract Image

使用可穿戴式智能女性垫简单监测全血pH值和尿素。
本研究采用线-纸微流控装置(μTPAD)系统,将全血处理的螺纹部分和血浆与固定化生物试剂反应的纸部分集成到女性垫中,作为可穿戴传感装置,即智能女性垫。μTPAD是一种可穿戴式智能女性检测板,用于检测实测血液中的pH值和尿素。方法:构建该组合装置,完成红细胞分离、调理、分析物反应和比色检测。在使用智能女性pad后,通过智能手机使用color Grab以RGB值测量感应区域的颜色变化。线程允许红细胞取样和分离,而纸微流控装置用于调理,生物识别和比色转导pH和尿素作为分析物。结果:平衡法测定两种分析物的分析时间均为110 s,尿素的检出限(LOD)为72.55 μg/mL,精密度为1.68%左右,pH为0.80%左右。智能女性尿垫可以快速检测月经血中的pH值和尿素,作为监测肾功能的真实样本,其结果与临床实验室普遍使用的常规方法一致。结论:智能女性护垫有潜力作为一种可穿戴设备,通过血液测量分析来监测用户的健康状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信