Combined Pipeline Embolization Device with Endoscopic Endonasal Fascia Lata/Muscle Graft Repair as a Salvage Technique for Treatment of Iatrogenic Carotid Artery Pseudoaneurysm.
Ann Liu, Jordina Rincon-Torroella, Matthew T Bender, Cameron G McDougall, Anthony P Tufaro, Nyall R London, Alexander L Coon, Douglas D Reh, Gary L Gallia
{"title":"Combined Pipeline Embolization Device with Endoscopic Endonasal Fascia Lata/Muscle Graft Repair as a Salvage Technique for Treatment of Iatrogenic Carotid Artery Pseudoaneurysm.","authors":"Ann Liu, Jordina Rincon-Torroella, Matthew T Bender, Cameron G McDougall, Anthony P Tufaro, Nyall R London, Alexander L Coon, Douglas D Reh, Gary L Gallia","doi":"10.1055/s-0041-1735284","DOIUrl":null,"url":null,"abstract":"<p><p>The incidence of internal carotid artery (ICA) injury associated with endoscopic endonasal approaches to the pituitary is less than 1%. While parent vessel sacrifice has historically been the choice of treatment, vessel-preserving endovascular techniques have been reported. Although flow diversion offers endoluminal reconstruction, its major limitation is the delay in obtaining complete occlusion. We describe the use of a combined Pipeline embolization device (PED) with endoscopic endonasal repair using a fascia lata/muscle graft to treat an iatrogenic ICA pseudoaneurysm and report long-term radiographic follow-up. Further investigation into the utility of directed endoscopic endonasal repair of iatrogenic pseudoaneurysms initially treated with PED is necessary, especially given the need of post-PED anticoagulation and the rate of permanent neurological deficit after ICA sacrifice.</p>","PeriodicalId":44256,"journal":{"name":"Journal of Neurological Surgery Reports","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/88/9b/10-1055-s-0041-1735284.PMC8635816.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neurological Surgery Reports","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0041-1735284","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/10/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
The incidence of internal carotid artery (ICA) injury associated with endoscopic endonasal approaches to the pituitary is less than 1%. While parent vessel sacrifice has historically been the choice of treatment, vessel-preserving endovascular techniques have been reported. Although flow diversion offers endoluminal reconstruction, its major limitation is the delay in obtaining complete occlusion. We describe the use of a combined Pipeline embolization device (PED) with endoscopic endonasal repair using a fascia lata/muscle graft to treat an iatrogenic ICA pseudoaneurysm and report long-term radiographic follow-up. Further investigation into the utility of directed endoscopic endonasal repair of iatrogenic pseudoaneurysms initially treated with PED is necessary, especially given the need of post-PED anticoagulation and the rate of permanent neurological deficit after ICA sacrifice.