Intra- and inter-rater reliability of compressed breast thickness, applied force, and pressure distribution in screening mammography.

IF 0.9 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Acta radiologica open Pub Date : 2021-12-09 eCollection Date: 2021-12-01 DOI:10.1177/20584601211062078
Martina Voigt, Anetta Bolejko, Magnus Dustler
{"title":"Intra- and inter-rater reliability of compressed breast thickness, applied force, and pressure distribution in screening mammography.","authors":"Martina Voigt,&nbsp;Anetta Bolejko,&nbsp;Magnus Dustler","doi":"10.1177/20584601211062078","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Ensuring equivalent and reproducible breast compression between mammographic screening rounds is important for the diagnostic performance of mammography, yet the extent to which screening mammography positioning and compression is reproducible for the individual woman is unknown.</p><p><strong>Purpose: </strong>To investigate the intra- and inter-rater reliability of breast compression in screening mammography.</p><p><strong>Materials and methods: </strong>Eleven breast-healthy women participated in the study. Two experienced radiographers independently positioned and compressed the breasts of each participant in two projections-right craniocaudal and left mediolateral oblique-and at two time points. The spatial pressure distribution on the compressed breast was measured using a pressure sensor matrix. Applied force, compressed breast thickness, force in field of view, contact area, mean pressure, and center of mass (anterio-posterior and mediolateral axes) were measured. The reliabilities of the measures between the time points for each radiographer (intra-rater reliability) and between the radiographers (inter-rater reliability) were analyzed using the intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>Intra- and inter-rater reliabilities from both projections demonstrated good to excellent ICCs (≥0.82) for compressed breast thickness, contact area, and anterio-posterior center of mass. The other measures produced ICCs that varied from poor (≤0.42) to excellent (≥0.93) between time points and between radiographers.</p><p><strong>Conclusion: </strong>Intra- and inter-rater reliability of breast compression was consistently high for <i>compressed breast thickness</i>, <i>contact area</i>, and <i>anterio-posterior center of mass</i> but low for <i>mediolateral center of mass</i> and <i>applied force</i>. Further research is needed to establish objective and clinically useful parameters for the standardization of breast compression.</p>","PeriodicalId":72063,"journal":{"name":"Acta radiologica open","volume":"10 12","pages":"20584601211062078"},"PeriodicalIF":0.9000,"publicationDate":"2021-12-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8819760/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta radiologica open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/20584601211062078","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Ensuring equivalent and reproducible breast compression between mammographic screening rounds is important for the diagnostic performance of mammography, yet the extent to which screening mammography positioning and compression is reproducible for the individual woman is unknown.

Purpose: To investigate the intra- and inter-rater reliability of breast compression in screening mammography.

Materials and methods: Eleven breast-healthy women participated in the study. Two experienced radiographers independently positioned and compressed the breasts of each participant in two projections-right craniocaudal and left mediolateral oblique-and at two time points. The spatial pressure distribution on the compressed breast was measured using a pressure sensor matrix. Applied force, compressed breast thickness, force in field of view, contact area, mean pressure, and center of mass (anterio-posterior and mediolateral axes) were measured. The reliabilities of the measures between the time points for each radiographer (intra-rater reliability) and between the radiographers (inter-rater reliability) were analyzed using the intraclass correlation coefficient (ICC).

Results: Intra- and inter-rater reliabilities from both projections demonstrated good to excellent ICCs (≥0.82) for compressed breast thickness, contact area, and anterio-posterior center of mass. The other measures produced ICCs that varied from poor (≤0.42) to excellent (≥0.93) between time points and between radiographers.

Conclusion: Intra- and inter-rater reliability of breast compression was consistently high for compressed breast thickness, contact area, and anterio-posterior center of mass but low for mediolateral center of mass and applied force. Further research is needed to establish objective and clinically useful parameters for the standardization of breast compression.

Abstract Image

Abstract Image

Abstract Image

乳腺压缩厚度、施加力和压力分布在筛查乳房x光检查中的内部和内部可靠性。
背景:确保乳房x线摄影筛查轮次之间的相同和可重复的乳房压迫对乳房x线摄影的诊断性能很重要,但筛查乳房x线摄影定位和压迫在个体女性中可重复的程度尚不清楚。目的:探讨乳腺压迫在筛查乳房x线摄影中的内部和内部可靠性。材料与方法:11名乳房健康的女性参与了本研究。两名经验丰富的放射线技师分别在两个时间点对每位参与者的乳房进行两次投影(右颅侧和左中外侧斜)定位和压缩。利用压力传感器矩阵测量压缩乳房上的空间压力分布。测量施加的力、压缩乳房厚度、视野内的力、接触面积、平均压力和质心(前后轴和中外侧轴)。使用类内相关系数(ICC)分析每个放射技师的时间点之间(分级内信度)和放射技师之间(分级间信度)的测量信度。结果:两种投影的内部和内部可靠性表明,压缩乳房厚度、接触面积和前后肿块中心的ICCs从良好到优异(≥0.82)。其他测量产生的icc在不同时间点和不同放射技师之间从差(≤0.42)到优(≥0.93)不等。结论:乳房压迫的内部和内部可靠性在被压迫乳房厚度、接触面积和前后肿块中心方面始终较高,而在中外侧肿块中心和施加的力方面则较低。需要进一步的研究来建立客观和临床有用的参数来标准化乳房压迫。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信