Organized Structure of Ventricular Fibrillation during Prolonged Heart Perfusion in Dogs.

IF 1.1 Q4 MEDICINE, RESEARCH & EXPERIMENTAL
Sovremennye Tehnologii v Medicine Pub Date : 2021-01-01 Epub Date: 2020-06-28 DOI:10.17691/stm2020.12.3.03
M I Guryanov, R S Pusev, N M Guryanova, E A Kharitonova, P K Yablonsky
{"title":"Organized Structure of Ventricular Fibrillation during Prolonged Heart Perfusion in Dogs.","authors":"M I Guryanov,&nbsp;R S Pusev,&nbsp;N M Guryanova,&nbsp;E A Kharitonova,&nbsp;P K Yablonsky","doi":"10.17691/stm2020.12.3.03","DOIUrl":null,"url":null,"abstract":"<p><p><b>The aim of the study</b> was to identify the organized ventricular fibrillation (VF) activity in the dog heart and characterize its quantitative parameters during prolonged heart perfusion.</p><p><strong>Materials and methods: </strong>A total of four experiments on isolated dog's hearts perfused with the blood of a supporting dog were performed. Episodes of VF were recorded in the form of an electrogram followed by a spectral analysis by the fast Fourier transform in the range of 0.5-15 Hz. The frequency, spectral power (amplitude), and relative weight (%) of the 1<sup>st</sup>, 2<sup>nd</sup>, and 3<sup>rd</sup> highest amplitude oscillations were determined (frequency - mode; amplitude, relative weight - M±SEM; n=120).</p><p><strong>Results: </strong>In the perfused dog heart, VF was characterized by an organized activity, as evidenced by the dominant structure of the oscillation frequencies. Oscillations with a frequency of 9-10 Hz (occurring in 1/10 of the 0.5-15 Hz range) represent 42-44% of the spectral power and dominate the structure of the oscillation frequencies. The frequency and spectral power of the dominating oscillations proved to be stable thus indicating that under perfusion, VF did not cause disturbances in the heart organized activity.</p><p><strong>Conclusion: </strong>Our experimentation with isolated perfused hearts revealed the patterns of VF that could not be revealed <i>in situ</i> under conditions complicated by nerve factors and ischemia in VF. The results of the work are protected with a patent which is applicable for VF diagnosis in implantable defibrillators.</p>","PeriodicalId":51886,"journal":{"name":"Sovremennye Tehnologii v Medicine","volume":"12 3","pages":"26-30"},"PeriodicalIF":1.1000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8596255/pdf/","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Sovremennye Tehnologii v Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17691/stm2020.12.3.03","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/6/28 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 1

Abstract

The aim of the study was to identify the organized ventricular fibrillation (VF) activity in the dog heart and characterize its quantitative parameters during prolonged heart perfusion.

Materials and methods: A total of four experiments on isolated dog's hearts perfused with the blood of a supporting dog were performed. Episodes of VF were recorded in the form of an electrogram followed by a spectral analysis by the fast Fourier transform in the range of 0.5-15 Hz. The frequency, spectral power (amplitude), and relative weight (%) of the 1st, 2nd, and 3rd highest amplitude oscillations were determined (frequency - mode; amplitude, relative weight - M±SEM; n=120).

Results: In the perfused dog heart, VF was characterized by an organized activity, as evidenced by the dominant structure of the oscillation frequencies. Oscillations with a frequency of 9-10 Hz (occurring in 1/10 of the 0.5-15 Hz range) represent 42-44% of the spectral power and dominate the structure of the oscillation frequencies. The frequency and spectral power of the dominating oscillations proved to be stable thus indicating that under perfusion, VF did not cause disturbances in the heart organized activity.

Conclusion: Our experimentation with isolated perfused hearts revealed the patterns of VF that could not be revealed in situ under conditions complicated by nerve factors and ischemia in VF. The results of the work are protected with a patent which is applicable for VF diagnosis in implantable defibrillators.

Abstract Image

Abstract Image

Abstract Image

犬心脏长时间灌注时心室颤动的组织结构。
本研究的目的是确定犬心脏有组织心室颤动(VF)活动,并表征其在心脏长时间灌注过程中的定量参数。材料与方法:在离体犬心脏上灌注支撑犬的血液,共进行4次实验。VF以电图的形式记录下来,然后用快速傅立叶变换在0.5- 15hz范围内进行频谱分析。确定第一、第二和第三最高振幅振荡的频率、频谱功率(振幅)和相对权重(%)(频率-模态;振幅,相对重量- M±SEM;n = 120)。结果:在灌注后的狗心脏中,VF具有有组织的活动特征,振荡频率占主导结构。频率为9- 10hz的振荡(发生在0.5- 15hz范围的1/10)代表了42-44%的频谱功率,并主导了振荡频率的结构。主要振荡的频率和频谱功率被证明是稳定的,这表明在灌注下,VF不会引起心脏有组织活动的干扰。结论:我们的离体灌注心脏实验揭示了在神经因素和心室纤维纤维缺血情况下原位无法显示的心室纤维纤维形态。这项工作的结果受到专利保护,该专利适用于植入式除颤器的VF诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Sovremennye Tehnologii v Medicine
Sovremennye Tehnologii v Medicine MEDICINE, RESEARCH & EXPERIMENTAL-
CiteScore
1.80
自引率
0.00%
发文量
38
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信