Novel Ultrasonographic Thickness and Strength Assessments of the Flexor Digitorum: A Reliability Analysis.

IF 0.9 4区 医学 Q3 MEDICINE, GENERAL & INTERNAL
Christos I Ioannou, Franziska L Hodde-Chriske, Marios N Avraamides, Eckart Altenmüller
{"title":"Novel Ultrasonographic Thickness and Strength Assessments of the Flexor Digitorum: A Reliability Analysis.","authors":"Christos I Ioannou,&nbsp;Franziska L Hodde-Chriske,&nbsp;Marios N Avraamides,&nbsp;Eckart Altenmüller","doi":"10.21091/mppa.2021.4030","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Clinical conditions such as focal dystonia often require the assessment of atrophy and weakness of the finger muscles. However, due to a lack of well-established protocols, the current investigation focused on assessing the reliability of thickness and strength assessments of the flexor digitorum (FD) muscle, including both the superficialis and profundus components. As a secondary assessment, the reliability of the strength measurement of the extensor digitorum muscle was examined as well.</p><p><strong>Methods: </strong>Different thickness measurements of the FD were taken via ultrasonography and averaged to estimate the mean thickness of the FD. Likewise, individual finger strength measurements taken by a custom-made finger pressure device were averaged to compute the mean strength of the flexor and extensor digitorum muscles. Test-retest reliability of the above measurements performed at two different time points (about 6 months apart) were examined on the right and left hands of 10 participants.</p><p><strong>Results: </strong>Findings indicated excellent test-retest reliability (ICC > 0.92) for the mean thickness assessment of the FD and mean strength of the flexor and extensor digitorum for both dominant and non-dominant hands. The standard error of measurement was ≤4.3% for all three mean assessments, indicating high sensitivity. Likewise, the smallest detectable change was also sufficiently small for the mean thickness and mean strength of the flexor digitorum (≤5.1%) and moderately small (≤12%) for the strength of the extensor digitorum.</p><p><strong>Conclusions: </strong>Results indicated an excellent relative and absolute reliability, for both hands, for the mean thickness and strength assessments of the flexor digitorum muscle and for the mean strength of the extensor digitorum (measured for both hands). These measurements can be used for future investigations and can contribute to the establishment of more precise methods for assessing the muscles in the forearms which serve the hand.</p>","PeriodicalId":18336,"journal":{"name":"Medical problems of performing artists","volume":"36 4","pages":"269-278"},"PeriodicalIF":0.9000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical problems of performing artists","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.21091/mppa.2021.4030","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 2

Abstract

Objectives: Clinical conditions such as focal dystonia often require the assessment of atrophy and weakness of the finger muscles. However, due to a lack of well-established protocols, the current investigation focused on assessing the reliability of thickness and strength assessments of the flexor digitorum (FD) muscle, including both the superficialis and profundus components. As a secondary assessment, the reliability of the strength measurement of the extensor digitorum muscle was examined as well.

Methods: Different thickness measurements of the FD were taken via ultrasonography and averaged to estimate the mean thickness of the FD. Likewise, individual finger strength measurements taken by a custom-made finger pressure device were averaged to compute the mean strength of the flexor and extensor digitorum muscles. Test-retest reliability of the above measurements performed at two different time points (about 6 months apart) were examined on the right and left hands of 10 participants.

Results: Findings indicated excellent test-retest reliability (ICC > 0.92) for the mean thickness assessment of the FD and mean strength of the flexor and extensor digitorum for both dominant and non-dominant hands. The standard error of measurement was ≤4.3% for all three mean assessments, indicating high sensitivity. Likewise, the smallest detectable change was also sufficiently small for the mean thickness and mean strength of the flexor digitorum (≤5.1%) and moderately small (≤12%) for the strength of the extensor digitorum.

Conclusions: Results indicated an excellent relative and absolute reliability, for both hands, for the mean thickness and strength assessments of the flexor digitorum muscle and for the mean strength of the extensor digitorum (measured for both hands). These measurements can be used for future investigations and can contribute to the establishment of more precise methods for assessing the muscles in the forearms which serve the hand.

新型超声测量指屈肌厚度和强度:可靠性分析。
目的:临床条件,如局灶性肌张力障碍往往需要评估萎缩和无力的手指肌肉。然而,由于缺乏完善的方案,目前的研究主要集中在评估指屈肌(FD)的厚度和强度评估的可靠性,包括浅肌和深肌成分。作为二次评估,也检查了指伸肌强度测量的可靠性。方法:采用超声测量FD的不同厚度,取其平均值,计算FD的平均厚度。同样,通过定制的手指压力装置对单个手指强度测量进行平均,以计算指屈肌和指伸肌的平均强度。在两个不同的时间点(大约相隔6个月)对10名参与者的右手和左手进行了上述测量的重测信度检验。结果:研究结果表明,对于优势手和非优势手,FD的平均厚度评估和指屈伸肌的平均强度,均具有良好的重测信度(ICC > 0.92)。三次平均评估的测量标准误差均≤4.3%,灵敏度较高。同样,最小的可检测变化对于指屈肌的平均厚度和平均强度也足够小(≤5.1%),对于指伸肌的强度也适度小(≤12%)。结论:结果表明,对于双手,对于指屈肌的平均厚度和强度评估以及指伸肌的平均强度(双手测量)具有极好的相对和绝对可靠性。这些测量可以用于未来的研究,并有助于建立更精确的方法来评估前臂的肌肉。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.60
自引率
22.20%
发文量
28
审稿时长
>12 weeks
期刊介绍: Medical Problems of Performing Artists is the first clinical medical journal devoted to the etiology, diagnosis, and treatment of medical and psychological disorders related to the performing arts. Original peer-reviewed research papers cover topics including neurologic disorders, musculoskeletal conditions, voice and hearing disorders, anxieties, stress, substance abuse, and other health issues related to actors, dancers, singers, musicians, and other performers.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信