Treatment of pilon fractures with low profile plates.

IF 1.4 Q3 EMERGENCY MEDICINE
International Journal of Burns and Trauma Pub Date : 2021-12-15 eCollection Date: 2021-01-01
Ali Andalib, Mohammad Reza Etemadifar, Aryan Rafiee Zadeh, Pouya Moshkdar
{"title":"Treatment of pilon fractures with low profile plates.","authors":"Ali Andalib,&nbsp;Mohammad Reza Etemadifar,&nbsp;Aryan Rafiee Zadeh,&nbsp;Pouya Moshkdar","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Treatments of pilon fracture is an important operative challenge due to high prevalence of post-operative complications. In this paper, we aimed to evaluate the complications of the use of low profile plates for pilon fractures.</p><p><strong>Methods: </strong>This clinical trial that was performed in 2017-2021 in Isfahan on 27 patients with pilon fractures. Demographic data of patients such as age, gender, type of pilon fracture and baseline pathology of pilon fractures were collected. Patients were treated using low profile plates under surgical procedures. Within 1 month, 3 months and 6 months after surgeries, patients were visited and assessed regarding superficial wound infections, deep wound infections, and evidence of osteomyelitis, vascular injuries, non-union and mal-union using both physical examinations and imaging studies via X-ray. We also measured the functions of cases using The American Orthopedic Foot and Ankle Score (AOFAS) questionnaire.</p><p><strong>Results: </strong>Most cases had 3 days (33.3%) and 5 days (33.3%) of hospitalization. Superficial wound infection was observed in 7 cases (26%). Deep surgical site infections were observed in 2 cases (7.4%) and we had only 1 case of osteomyelitis (3.7%). No vascular injuries were observed in this study. Evaluation of union among patients showed that 2 cases (7.4%) had non-union and 5 cases (18.5%) had malunion in the anterior-posterior axis, but none of the patients had malunion in the coronal axis. Based on AOFAS questionnaire, the mean score in patients was 88.36±14.20.</p><p><strong>Conclusion: </strong>Treatments of pilon fractures by low profile plates have similar complications compared to other treatment options.</p>","PeriodicalId":45488,"journal":{"name":"International Journal of Burns and Trauma","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2021-12-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8784745/pdf/ijbt0011-0486.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Burns and Trauma","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"EMERGENCY MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Treatments of pilon fracture is an important operative challenge due to high prevalence of post-operative complications. In this paper, we aimed to evaluate the complications of the use of low profile plates for pilon fractures.

Methods: This clinical trial that was performed in 2017-2021 in Isfahan on 27 patients with pilon fractures. Demographic data of patients such as age, gender, type of pilon fracture and baseline pathology of pilon fractures were collected. Patients were treated using low profile plates under surgical procedures. Within 1 month, 3 months and 6 months after surgeries, patients were visited and assessed regarding superficial wound infections, deep wound infections, and evidence of osteomyelitis, vascular injuries, non-union and mal-union using both physical examinations and imaging studies via X-ray. We also measured the functions of cases using The American Orthopedic Foot and Ankle Score (AOFAS) questionnaire.

Results: Most cases had 3 days (33.3%) and 5 days (33.3%) of hospitalization. Superficial wound infection was observed in 7 cases (26%). Deep surgical site infections were observed in 2 cases (7.4%) and we had only 1 case of osteomyelitis (3.7%). No vascular injuries were observed in this study. Evaluation of union among patients showed that 2 cases (7.4%) had non-union and 5 cases (18.5%) had malunion in the anterior-posterior axis, but none of the patients had malunion in the coronal axis. Based on AOFAS questionnaire, the mean score in patients was 88.36±14.20.

Conclusion: Treatments of pilon fractures by low profile plates have similar complications compared to other treatment options.

Abstract Image

低轮廓钢板治疗枕部骨折。
背景:由于术后并发症的高发,治疗枕部骨折是一个重要的手术挑战。在本文中,我们的目的是评估使用低轮廓钢板治疗枕部骨折的并发症。方法:该临床试验于2017-2021年在伊斯法罕对27例皮隆骨折患者进行。收集患者年龄、性别、枕部骨折类型、枕部骨折基线病理等人口学资料。患者在手术过程中使用低轮廓钢板治疗。在术后1个月、3个月和6个月内,通过体格检查和x线影像学检查对患者进行检查,评估伤口浅表感染、深部感染、骨髓炎、血管损伤、骨不连和骨不连的证据。我们还使用美国骨科足踝评分(AOFAS)问卷来测量病例的功能。结果:多数病例住院时间为3 d (33.3%), 5 d(33.3%)。创面感染7例(26%)。深部手术部位感染2例(7.4%),骨髓炎1例(3.7%)。本研究未见血管损伤。患者愈合评价显示2例(7.4%)不愈合,5例(18.5%)前后轴不愈合,冠状轴不愈合无一例。基于AOFAS问卷,患者平均得分为88.36±14.20分。结论:与其他治疗方案相比,采用低轮廓钢板治疗枕部骨折并发症相似。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
12.50%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信