Christina Eckmann-Hansen, Mathias Hvidtfelt Hansen, Poul Pedersen Laigaard, Birgit Agnes Sander, Inger Christine Munch, Else Marie Olsen, Anne Mette Skovgaard, Michael Larsen
{"title":"Cone photoreceptor density in the Copenhagen Child Cohort at age 16-17 years.","authors":"Christina Eckmann-Hansen, Mathias Hvidtfelt Hansen, Poul Pedersen Laigaard, Birgit Agnes Sander, Inger Christine Munch, Else Marie Olsen, Anne Mette Skovgaard, Michael Larsen","doi":"10.1111/opo.12889","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine cone density in relation to gestational and morphological parameters in the Copenhagen Child Cohort (CCC2000).</p><p><strong>Methods: </strong>The macula was imaged using adaptive optics in 1,296 adolescents aged 16-17 years. Axial length and distance visual acuity were determined. Absolute and angular cone photoreceptor density were analysed for an 80 × 80-pixel area, 2 degrees temporal to the fovea. Association with axial length was analysed with linear regression. Correlation with visual acuity was described with a Pearson correlation coefficient. Associations of cone density with gestational parameters, maternal smoking, sex and age were analysed using multiple regression adjusted for axial length.</p><p><strong>Results: </strong>Mean absolute cone density was 30,007 cones/mm<sup>2</sup> (SD ± 3,802) and mean angular cone density was 2,383 cones/deg<sup>2</sup> (SD ± 231). Peri- and postnatal parameters, sex and age had no statistically significant effect on cone density (p > 0.05). Absolute cone density decreased with longer axial length (-2,855 cones/mm<sup>2</sup> per mm or -9.7% per mm, p < 0.0001). For angular density, which included a correction for the geometrical enlargement of the eye with axial length, a decrease with axial length was detectable, but it was small (-20 cones/deg<sup>2</sup> per mm or -0.84% per mm, p = 0.009).</p><p><strong>Conclusions: </strong>The decrease in cone density per unit solid angle with increasing axial length was small, less than 1 percent per mm, indicating that expansion of the posterior pole during the development of refraction takes place without a clinically significant loss of cones. Perinatal parameters, within the spectrum presented by the study population, had no detectable effect on cone density.</p>","PeriodicalId":520731,"journal":{"name":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","volume":" ","pages":"1292-1299"},"PeriodicalIF":2.4000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.12889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/9/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5
Abstract
Purpose: To examine cone density in relation to gestational and morphological parameters in the Copenhagen Child Cohort (CCC2000).
Methods: The macula was imaged using adaptive optics in 1,296 adolescents aged 16-17 years. Axial length and distance visual acuity were determined. Absolute and angular cone photoreceptor density were analysed for an 80 × 80-pixel area, 2 degrees temporal to the fovea. Association with axial length was analysed with linear regression. Correlation with visual acuity was described with a Pearson correlation coefficient. Associations of cone density with gestational parameters, maternal smoking, sex and age were analysed using multiple regression adjusted for axial length.
Results: Mean absolute cone density was 30,007 cones/mm2 (SD ± 3,802) and mean angular cone density was 2,383 cones/deg2 (SD ± 231). Peri- and postnatal parameters, sex and age had no statistically significant effect on cone density (p > 0.05). Absolute cone density decreased with longer axial length (-2,855 cones/mm2 per mm or -9.7% per mm, p < 0.0001). For angular density, which included a correction for the geometrical enlargement of the eye with axial length, a decrease with axial length was detectable, but it was small (-20 cones/deg2 per mm or -0.84% per mm, p = 0.009).
Conclusions: The decrease in cone density per unit solid angle with increasing axial length was small, less than 1 percent per mm, indicating that expansion of the posterior pole during the development of refraction takes place without a clinically significant loss of cones. Perinatal parameters, within the spectrum presented by the study population, had no detectable effect on cone density.