Cone photoreceptor density in the Copenhagen Child Cohort at age 16-17 years.

IF 2.4
Christina Eckmann-Hansen, Mathias Hvidtfelt Hansen, Poul Pedersen Laigaard, Birgit Agnes Sander, Inger Christine Munch, Else Marie Olsen, Anne Mette Skovgaard, Michael Larsen
{"title":"Cone photoreceptor density in the Copenhagen Child Cohort at age 16-17 years.","authors":"Christina Eckmann-Hansen,&nbsp;Mathias Hvidtfelt Hansen,&nbsp;Poul Pedersen Laigaard,&nbsp;Birgit Agnes Sander,&nbsp;Inger Christine Munch,&nbsp;Else Marie Olsen,&nbsp;Anne Mette Skovgaard,&nbsp;Michael Larsen","doi":"10.1111/opo.12889","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To examine cone density in relation to gestational and morphological parameters in the Copenhagen Child Cohort (CCC2000).</p><p><strong>Methods: </strong>The macula was imaged using adaptive optics in 1,296 adolescents aged 16-17 years. Axial length and distance visual acuity were determined. Absolute and angular cone photoreceptor density were analysed for an 80 × 80-pixel area, 2 degrees temporal to the fovea. Association with axial length was analysed with linear regression. Correlation with visual acuity was described with a Pearson correlation coefficient. Associations of cone density with gestational parameters, maternal smoking, sex and age were analysed using multiple regression adjusted for axial length.</p><p><strong>Results: </strong>Mean absolute cone density was 30,007 cones/mm<sup>2</sup> (SD ± 3,802) and mean angular cone density was 2,383 cones/deg<sup>2</sup> (SD ± 231). Peri- and postnatal parameters, sex and age had no statistically significant effect on cone density (p > 0.05). Absolute cone density decreased with longer axial length (-2,855 cones/mm<sup>2</sup> per mm or -9.7% per mm, p < 0.0001). For angular density, which included a correction for the geometrical enlargement of the eye with axial length, a decrease with axial length was detectable, but it was small (-20 cones/deg<sup>2</sup> per mm or -0.84% per mm, p = 0.009).</p><p><strong>Conclusions: </strong>The decrease in cone density per unit solid angle with increasing axial length was small, less than 1 percent per mm, indicating that expansion of the posterior pole during the development of refraction takes place without a clinically significant loss of cones. Perinatal parameters, within the spectrum presented by the study population, had no detectable effect on cone density.</p>","PeriodicalId":520731,"journal":{"name":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","volume":" ","pages":"1292-1299"},"PeriodicalIF":2.4000,"publicationDate":"2021-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic & physiological optics : the journal of the British College of Ophthalmic Opticians (Optometrists)","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/opo.12889","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/9/24 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Purpose: To examine cone density in relation to gestational and morphological parameters in the Copenhagen Child Cohort (CCC2000).

Methods: The macula was imaged using adaptive optics in 1,296 adolescents aged 16-17 years. Axial length and distance visual acuity were determined. Absolute and angular cone photoreceptor density were analysed for an 80 × 80-pixel area, 2 degrees temporal to the fovea. Association with axial length was analysed with linear regression. Correlation with visual acuity was described with a Pearson correlation coefficient. Associations of cone density with gestational parameters, maternal smoking, sex and age were analysed using multiple regression adjusted for axial length.

Results: Mean absolute cone density was 30,007 cones/mm2 (SD ± 3,802) and mean angular cone density was 2,383 cones/deg2 (SD ± 231). Peri- and postnatal parameters, sex and age had no statistically significant effect on cone density (p > 0.05). Absolute cone density decreased with longer axial length (-2,855 cones/mm2 per mm or -9.7% per mm, p < 0.0001). For angular density, which included a correction for the geometrical enlargement of the eye with axial length, a decrease with axial length was detectable, but it was small (-20 cones/deg2 per mm or -0.84% per mm, p = 0.009).

Conclusions: The decrease in cone density per unit solid angle with increasing axial length was small, less than 1 percent per mm, indicating that expansion of the posterior pole during the development of refraction takes place without a clinically significant loss of cones. Perinatal parameters, within the spectrum presented by the study population, had no detectable effect on cone density.

哥本哈根16-17岁儿童队列的视锥细胞光感受器密度
目的:研究哥本哈根儿童队列(CCC2000)中锥体密度与妊娠期和形态参数的关系。方法:对1296例16 ~ 17岁青少年的黄斑进行自适应光学成像。测定眼轴长度和距离视力。在距中央凹2度的80 × 80像素区域,分析绝对锥光感受器密度和角锥光感受器密度。用线性回归分析与轴长的关系。与视力的相关性用Pearson相关系数来描述。使用调整轴长后的多元回归分析了锥体密度与妊娠参数、母亲吸烟、性别和年龄的关系。结果:平均绝对锥密度为30,007锥/mm2 (SD±3,802),平均角锥密度为2,383锥/deg2 (SD±231)。出生前后参数、性别和年龄对锥体密度的影响均无统计学意义(p > 0.05)。绝对锥密度随着轴向长度的增加而降低(-2,855个锥/mm2 /mm或-9.7% /mm, p 2 /mm或-0.84% /mm, p = 0.009)。结论:随着轴向长度的增加,每单位立体角锥体密度的下降很小,每毫米不到1%,这表明在屈光发展过程中,后极的扩张发生了,但没有临床上显著的锥体损失。围产期参数,在研究人群提供的频谱内,对锥体密度没有可检测到的影响。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信