Low-Intensity Ultrasound as a Novel Strategy to Improve the Cytotoxic Effect of Oncolytic Reovirus on Colorectal Cancer Model Cells.

IF 4.3 3区 材料科学 Q1 ENGINEERING, ELECTRICAL & ELECTRONIC
ACS Applied Electronic Materials Pub Date : 2022-01-01 Epub Date: 2021-09-10 DOI:10.1159/000519492
Negar Sharifi, Hoorieh Soleimanjahi, Manijeh Mokhtari-Dizaji, Razieh Sadat Banijamali, Maliheh Elhamipour, Hesam Karimi
{"title":"Low-Intensity Ultrasound as a Novel Strategy to Improve the Cytotoxic Effect of Oncolytic Reovirus on Colorectal Cancer Model Cells.","authors":"Negar Sharifi,&nbsp;Hoorieh Soleimanjahi,&nbsp;Manijeh Mokhtari-Dizaji,&nbsp;Razieh Sadat Banijamali,&nbsp;Maliheh Elhamipour,&nbsp;Hesam Karimi","doi":"10.1159/000519492","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Colorectal cancer is the third most common cancer all over the world, so in the battle to fight this hurdle, new therapeutic approaches such as oncolytic viruses (OV) have attracted much attention because of the fact that they can inherently kill cancer cells. Oncolytic reovirus is one of the candidates for treatment as a nonpathogenic species specially reovirus type 3 Dearing (T3D), which can induce apoptosis. To speed up the entry and function of the reovirus, low-intensity ultrasound, which is a safe system for damage to the cells and tissues, is a promising approach to be used in combination with other therapeutic approach.</p><p><strong>Methods: </strong>L929 and CT26 cells were infected with reovirus T3D and were exposed to ultrasonic irradiation (1 MHz, 1 W/cm2, and 20% duty factor) for 10 s. The viruses' titer level of both groups was calculated in 2 types of cells by using the CCID50 method and compared with each other. Apoptosis, after 24 h, was measured by the flow cytometry method.</p><p><strong>Result: </strong>The results of CCID50 in infected cells were exposed to low-intensity ultrasound showed an increased virus titer compared with unexposed infected cells. Moreover, according to the results of the flow cytometry test, it was found that the amount of apoptosis in infected cells that are exposed to low-intensity ultrasound waves is higher than those infected cells.</p><p><strong>Conclusion: </strong>Due to the results of CCID50 and flow cytometry tests, low-intensity ultrasound increases the cytotoxicity level of reovirus in CT26 cells of the cellular colorectal cancer model.</p>","PeriodicalId":3,"journal":{"name":"ACS Applied Electronic Materials","volume":null,"pages":null},"PeriodicalIF":4.3000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Applied Electronic Materials","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1159/000519492","RegionNum":3,"RegionCategory":"材料科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/9/10 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Colorectal cancer is the third most common cancer all over the world, so in the battle to fight this hurdle, new therapeutic approaches such as oncolytic viruses (OV) have attracted much attention because of the fact that they can inherently kill cancer cells. Oncolytic reovirus is one of the candidates for treatment as a nonpathogenic species specially reovirus type 3 Dearing (T3D), which can induce apoptosis. To speed up the entry and function of the reovirus, low-intensity ultrasound, which is a safe system for damage to the cells and tissues, is a promising approach to be used in combination with other therapeutic approach.

Methods: L929 and CT26 cells were infected with reovirus T3D and were exposed to ultrasonic irradiation (1 MHz, 1 W/cm2, and 20% duty factor) for 10 s. The viruses' titer level of both groups was calculated in 2 types of cells by using the CCID50 method and compared with each other. Apoptosis, after 24 h, was measured by the flow cytometry method.

Result: The results of CCID50 in infected cells were exposed to low-intensity ultrasound showed an increased virus titer compared with unexposed infected cells. Moreover, according to the results of the flow cytometry test, it was found that the amount of apoptosis in infected cells that are exposed to low-intensity ultrasound waves is higher than those infected cells.

Conclusion: Due to the results of CCID50 and flow cytometry tests, low-intensity ultrasound increases the cytotoxicity level of reovirus in CT26 cells of the cellular colorectal cancer model.

低强度超声作为提高溶瘤呼肠孤病毒对结直肠癌模型细胞毒性作用的新策略。
背景:结直肠癌是世界上第三大常见癌症,因此在与这一障碍的斗争中,溶瘤病毒(OV)等新的治疗方法因其固有的杀死癌细胞的能力而引起了人们的广泛关注。溶瘤性呼肠孤病毒是一种非致病性病毒,特别是可诱导细胞凋亡的呼肠孤病毒3型(T3D)。为了加速呼肠孤病毒的进入和发挥作用,低强度超声作为一种对细胞和组织损伤的安全系统,是一种有希望与其他治疗方法联合使用的方法。方法:用呼肠孤病毒T3D感染L929和CT26细胞,在超声(1 MHz, 1 W/cm2, 20%占空因子)下照射10 s。采用CCID50法计算两组病毒在2种细胞中的滴度水平,并进行比较。24h后用流式细胞术检测细胞凋亡。结果:感染细胞经低强度超声暴露后,CCID50病毒滴度较未暴露的感染细胞明显升高。此外,根据流式细胞术检测结果,发现低强度超声照射下感染细胞的凋亡数量高于感染细胞。结论:CCID50和流式细胞术检测结果显示,低强度超声可提高呼肠孤病毒对细胞性结直肠癌模型CT26细胞的细胞毒性水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.20
自引率
4.30%
发文量
567
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信