Clinical Walking Tests and Gait Pattern Characterization During 6-Minute Walk Test Using Inertial Sensors: Follow-Up in Individuals With Lower Limb Amputation.
Hananeh Younesian, Thomas Legrand, Ludovic Miramand, Sarah Beausoleil, Katia Turcot
{"title":"Clinical Walking Tests and Gait Pattern Characterization During 6-Minute Walk Test Using Inertial Sensors: Follow-Up in Individuals With Lower Limb Amputation.","authors":"Hananeh Younesian, Thomas Legrand, Ludovic Miramand, Sarah Beausoleil, Katia Turcot","doi":"10.1123/jab.2020-0327","DOIUrl":null,"url":null,"abstract":"<p><p>Inertial measurement units and normative values enable clinicians to quantify clinical walking tests and set rehabilitation goals. Objectives of this study were (1) to compare time- and distance-based walking tests in individuals with lower limb amputation (iLLA) and normative values following rehabilitation discharge (T1) and 6 weeks after discharge (T2) and (2) to investigate spatiotemporal and foot kinematic parameters over a 6-minute walk test using inertial measurement units. Twelve iLLA participated in this study. Distance, cadence, stance ratio, loading rate ratio, push-up ratio, path length, and minimum toe clearance were analyzed during 6-minute walk test. Nonparametric repeated-measures analysis of variance tests, Bonferroni corrections, were performed. Time of distance-based walking tests diminished at T2 (P < .02). Compared with normative values, walking performance in iLLA was reduced. Cadence at T2 increased significantly (P = .026). Stance ratio increased in both legs at T2 (P < .05). Push-up ratio tended to decrease at T2 in the amputated leg (P = .0003). Variability of path length and minimum toe clearance at T2 were less than at T1 in the nonamputated leg (P < .05). Spatiotemporal improvement at T2 could be due to prosthesis adaptation in iLLA. The lower performance of the functional walk test compared with normative values could be due to amputation and pain-related fatigue.</p>","PeriodicalId":54883,"journal":{"name":"Journal of Applied Biomechanics","volume":"37 5","pages":"440-449"},"PeriodicalIF":1.1000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Biomechanics","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1123/jab.2020-0327","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/9/9 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0
Abstract
Inertial measurement units and normative values enable clinicians to quantify clinical walking tests and set rehabilitation goals. Objectives of this study were (1) to compare time- and distance-based walking tests in individuals with lower limb amputation (iLLA) and normative values following rehabilitation discharge (T1) and 6 weeks after discharge (T2) and (2) to investigate spatiotemporal and foot kinematic parameters over a 6-minute walk test using inertial measurement units. Twelve iLLA participated in this study. Distance, cadence, stance ratio, loading rate ratio, push-up ratio, path length, and minimum toe clearance were analyzed during 6-minute walk test. Nonparametric repeated-measures analysis of variance tests, Bonferroni corrections, were performed. Time of distance-based walking tests diminished at T2 (P < .02). Compared with normative values, walking performance in iLLA was reduced. Cadence at T2 increased significantly (P = .026). Stance ratio increased in both legs at T2 (P < .05). Push-up ratio tended to decrease at T2 in the amputated leg (P = .0003). Variability of path length and minimum toe clearance at T2 were less than at T1 in the nonamputated leg (P < .05). Spatiotemporal improvement at T2 could be due to prosthesis adaptation in iLLA. The lower performance of the functional walk test compared with normative values could be due to amputation and pain-related fatigue.
期刊介绍:
The mission of the Journal of Applied Biomechanics (JAB) is to disseminate the highest quality peer-reviewed studies that utilize biomechanical strategies to advance the study of human movement. Areas of interest include clinical biomechanics, gait and posture mechanics, musculoskeletal and neuromuscular biomechanics, sport mechanics, and biomechanical modeling. Studies of sport performance that explicitly generalize to broader activities, contribute substantially to fundamental understanding of human motion, or are in a sport that enjoys wide participation, are welcome. Also within the scope of JAB are studies using biomechanical strategies to investigate the structure, control, function, and state (health and disease) of animals.