125Te NMR for structural investigations in phase change materials: Optimization of experimental conditions coupled to NMR shift prediction

IF 1.8 3区 化学 Q4 CHEMISTRY, PHYSICAL
J. Lizion , A. Piarristeguy , R. Laskowski , P. Blaha , R. Escalier , M. Ménétrier , A. Pradel , G. Silly
{"title":"125Te NMR for structural investigations in phase change materials: Optimization of experimental conditions coupled to NMR shift prediction","authors":"J. Lizion ,&nbsp;A. Piarristeguy ,&nbsp;R. Laskowski ,&nbsp;P. Blaha ,&nbsp;R. Escalier ,&nbsp;M. Ménétrier ,&nbsp;A. Pradel ,&nbsp;G. Silly","doi":"10.1016/j.ssnmr.2021.101751","DOIUrl":null,"url":null,"abstract":"<div><p><span><span>Phase Change Materials as those of the Ge-Sb-Te </span>ternary system are of great interest for technological applications. Properties of these compounds are strongly related to presence of vacancies and structural investigations remain challenging. In this paper we evidence that </span><sup>125</sup><span>Te NMR in natural abundance and using commercial systems at intermediate field (14.1 ​T) together with NMR parameters prediction can contribute to improve understanding of electronic structure of such systems. GeTe is a typical phase change material, whose structure contains germanium vacancies, even in its stoichiometric form, giving it metallic properties. Here, we use nominal Ge</span><sub>50</sub>Te<sub>50</sub> and Ge<sub>48</sub>Te<sub>52</sub><span> crystalline samples as an example to optimize the WURST-CPMG technique, a powerful technique to record wide NMR spectra which has not yet been used on </span><sup>125</sup>Te. The goal was to minimize the time devoted to experiments as well as maximize the signal-to-noise ratio in order to detect small intensity signals directly linked to vacancies. Virtual Crystal Approximation (VCA) calculations performed with WIEN2K helped to interpret the NMR spectra. For Te-based crystalline conducting samples the best experimental results were obtained using 3.2 ​mm thin wall rotors with diluted samples 40 ​vol% GeTe-60 ​vol% SiO<sub>2</sub><span>. In addition to the WURST-CPMG technique, high resolution spectra using MAS<span> as implemented in the pj-MAT technique allowed us to identify the distributions of chemical shift parameters in the high intensity contribution of the 1D spectra. The NMR spectra recorded on the samples showed that an addition of Tellurium in the stoichiometric Ge</span></span><sub>50</sub>Te<sub>50</sub> sample leads to an important broadening of the spectrum together with a shift of the lines. According to VCA calculations it could be attributed to a distribution of concentrations of germanium vacancies in the sample and it would appear that Knight Shift but also Chemical Shift could contribute in similar proportion to the NMR line position when metavalent bonding is invoked.</p></div>","PeriodicalId":21937,"journal":{"name":"Solid state nuclear magnetic resonance","volume":"115 ","pages":"Article 101751"},"PeriodicalIF":1.8000,"publicationDate":"2021-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ssnmr.2021.101751","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Solid state nuclear magnetic resonance","FirstCategoryId":"92","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0926204021000394","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 1

Abstract

Phase Change Materials as those of the Ge-Sb-Te ternary system are of great interest for technological applications. Properties of these compounds are strongly related to presence of vacancies and structural investigations remain challenging. In this paper we evidence that 125Te NMR in natural abundance and using commercial systems at intermediate field (14.1 ​T) together with NMR parameters prediction can contribute to improve understanding of electronic structure of such systems. GeTe is a typical phase change material, whose structure contains germanium vacancies, even in its stoichiometric form, giving it metallic properties. Here, we use nominal Ge50Te50 and Ge48Te52 crystalline samples as an example to optimize the WURST-CPMG technique, a powerful technique to record wide NMR spectra which has not yet been used on 125Te. The goal was to minimize the time devoted to experiments as well as maximize the signal-to-noise ratio in order to detect small intensity signals directly linked to vacancies. Virtual Crystal Approximation (VCA) calculations performed with WIEN2K helped to interpret the NMR spectra. For Te-based crystalline conducting samples the best experimental results were obtained using 3.2 ​mm thin wall rotors with diluted samples 40 ​vol% GeTe-60 ​vol% SiO2. In addition to the WURST-CPMG technique, high resolution spectra using MAS as implemented in the pj-MAT technique allowed us to identify the distributions of chemical shift parameters in the high intensity contribution of the 1D spectra. The NMR spectra recorded on the samples showed that an addition of Tellurium in the stoichiometric Ge50Te50 sample leads to an important broadening of the spectrum together with a shift of the lines. According to VCA calculations it could be attributed to a distribution of concentrations of germanium vacancies in the sample and it would appear that Knight Shift but also Chemical Shift could contribute in similar proportion to the NMR line position when metavalent bonding is invoked.

Abstract Image

用于相变材料结构研究的核磁共振:结合核磁共振位移预测的实验条件优化
Ge-Sb-Te三元体系相变材料在技术应用上具有重要的意义。这些化合物的性质与空位的存在密切相关,结构研究仍然具有挑战性。在本文中,我们证明了自然丰度的125Te核磁共振和在中间场(14.1 T)使用商业系统以及核磁共振参数预测有助于提高对这类系统的电子结构的理解。GeTe是一种典型的相变材料,其结构包含锗空位,即使在其化学计量形式中,也赋予其金属性质。在这里,我们以Ge50Te50和Ge48Te52晶体样品为例来优化WURST-CPMG技术,这是一种强大的技术,可以记录尚未用于125Te的宽NMR光谱。目标是尽量减少用于实验的时间,并最大限度地提高信噪比,以便检测与空缺直接相关的小强度信号。用WIEN2K进行的虚拟晶体近似(VCA)计算有助于解释核磁共振光谱。对于te基晶体导电样品,使用稀释样品40 vol% GeTe-60 vol% SiO2的3.2 mm薄壁转子获得最佳实验结果。除了WURST-CPMG技术,在pj-MAT技术中实现的使用MAS的高分辨率光谱使我们能够确定1D光谱中高强度贡献的化学位移参数的分布。在样品上记录的核磁共振光谱表明,在化学计量的Ge50Te50样品中加入碲会导致光谱的重要拓宽和谱线的移位。根据VCA计算,它可以归因于样品中锗空位浓度的分布,并且当调用元价键时,奈特位移和化学位移似乎可以以相似的比例贡献核磁共振线位置。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
5.30
自引率
9.40%
发文量
42
审稿时长
72 days
期刊介绍: The journal Solid State Nuclear Magnetic Resonance publishes original manuscripts of high scientific quality dealing with all experimental and theoretical aspects of solid state NMR. This includes advances in instrumentation, development of new experimental techniques and methodology, new theoretical insights, new data processing and simulation methods, and original applications of established or novel methods to scientific problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信