Catheter-Mounted CMOS Front-Ends for Broadband Intravascular Ultrasonic Imaging.

Steve J A Majerus, Soumyajit Mandal, Aaron Fleischman
{"title":"Catheter-Mounted CMOS Front-Ends for Broadband Intravascular Ultrasonic Imaging.","authors":"Steve J A Majerus, Soumyajit Mandal, Aaron Fleischman","doi":"10.1109/mwscas.2017.8052938","DOIUrl":null,"url":null,"abstract":"<p><p>Intravascular ultrasonic (IVUS) imaging catheters currently use ceramic piezoelectric transducers to form radial images of blood vessel walls. Further improvements in image quality may be enabled through Capacitive and Piezoelectric Micromachined Ultrasonic Transducers (CMUTs and PMUTs). Polymer PMUTs offer many benefits in imaging quality, however, the low acoustic sensitivity and high electrical impedance of polymer PMUTs prevents unbuffered use with 50-Ω IVUS cables. Here, we present the design and optimization of an integrated CMOS front-end specifically designed to be integrated on a 0.8-mm imaging catheter. A series-duplexer topology with active limiter was selected for simplicity of integration, and compatibility with conventional high-voltage IVUS pulser-receiver systems. Noise optimization of the front-end revealed that an impedance-matching optimum exists, which balances the system parasitic capacitances relative to the transducer complex impedance. Optimized design equations compared favorably to simulation results in predicting front-end bandwidth and transducer-referred SNR. Large-signal transient simulation showed that the front-end can withstand 100-V pulses while recovering in 240 ns for echo reception. The integrated front-end occupied 0.74 × 1.8 mm die area (including large solder-bump bond pads), with an estimated transducer-referred noise floor of 6.5 <math> <mrow> <mrow> <msub><mrow><mi>n</mi> <mi>V</mi></mrow> <mrow><mi>R</mi> <mi>M</mi> <mi>S</mi></mrow> </msub> </mrow> <mo>/</mo> <mrow><msqrt><mi>H</mi> <mi>z</mi></msqrt> </mrow> </mrow> </math> over a 100-MHz imaging bandwidth.</p>","PeriodicalId":89019,"journal":{"name":"The ... Midwest Symposium on Circuits and Systems conference proceedings : MWSCAS. Midwest Symposium on Circuits and Systems","volume":"2017 ","pages":"373-376"},"PeriodicalIF":0.0000,"publicationDate":"2017-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8211115/pdf/nihms-1690187.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The ... Midwest Symposium on Circuits and Systems conference proceedings : MWSCAS. Midwest Symposium on Circuits and Systems","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/mwscas.2017.8052938","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/10/2 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Intravascular ultrasonic (IVUS) imaging catheters currently use ceramic piezoelectric transducers to form radial images of blood vessel walls. Further improvements in image quality may be enabled through Capacitive and Piezoelectric Micromachined Ultrasonic Transducers (CMUTs and PMUTs). Polymer PMUTs offer many benefits in imaging quality, however, the low acoustic sensitivity and high electrical impedance of polymer PMUTs prevents unbuffered use with 50-Ω IVUS cables. Here, we present the design and optimization of an integrated CMOS front-end specifically designed to be integrated on a 0.8-mm imaging catheter. A series-duplexer topology with active limiter was selected for simplicity of integration, and compatibility with conventional high-voltage IVUS pulser-receiver systems. Noise optimization of the front-end revealed that an impedance-matching optimum exists, which balances the system parasitic capacitances relative to the transducer complex impedance. Optimized design equations compared favorably to simulation results in predicting front-end bandwidth and transducer-referred SNR. Large-signal transient simulation showed that the front-end can withstand 100-V pulses while recovering in 240 ns for echo reception. The integrated front-end occupied 0.74 × 1.8 mm die area (including large solder-bump bond pads), with an estimated transducer-referred noise floor of 6.5 n V R M S / H z over a 100-MHz imaging bandwidth.

Abstract Image

Abstract Image

Abstract Image

用于宽带血管内超声波成像的导管安装式 CMOS 前端。
血管内超声波(IVUS)成像导管目前使用陶瓷压电换能器来形成血管壁的径向图像。电容式和压电式微机械超声换能器(CMUT 和 PMUT)可进一步提高成像质量。聚合物 PMUT 在成像质量方面有很多优点,但由于聚合物 PMUT 的声灵敏度低、电阻抗高,因此无法与 50Ω IVUS 电缆一起使用。在此,我们介绍了集成 CMOS 前端的设计和优化,该前端专为集成在 0.8 毫米成像导管上而设计。我们选择了带有源限幅器的串联双工拓扑结构,以简化集成,并与传统的高压 IVUS 脉冲接收器系统兼容。前端噪声优化显示存在阻抗匹配最佳值,该值平衡了系统寄生电容与传感器复阻抗之间的关系。在预测前端带宽和换能器参考信噪比方面,优化后的设计方程与仿真结果相差无几。大信号瞬态仿真显示,前端可承受 100 V 脉冲,并在 240 ns 内恢复以接收回音。集成前端占用 0.74 × 1.8 mm 的芯片面积(包括大焊块接合焊盘),在 100-MHz 成像带宽上,估计换能器参考噪声本底为 6.5 n V R M S / H z。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
1.70
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书