Nosocomial Outbreak of COVID-19 in a Hematologic Ward.

IF 2.9
Jiwon Jung, Jungmin Lee, Seongmin Jo, Seongman Bae, Ji Yeun Kim, Hye Hee Cha, Young Ju Lim, Sun Hee Kwak, Min Jee Hong, Eun Ok Kim, Joon Yong Bae, Changmin Kang, Minki Sung, Man Seong Park, Sung Han Kim
{"title":"Nosocomial Outbreak of COVID-19 in a Hematologic Ward.","authors":"Jiwon Jung,&nbsp;Jungmin Lee,&nbsp;Seongmin Jo,&nbsp;Seongman Bae,&nbsp;Ji Yeun Kim,&nbsp;Hye Hee Cha,&nbsp;Young Ju Lim,&nbsp;Sun Hee Kwak,&nbsp;Min Jee Hong,&nbsp;Eun Ok Kim,&nbsp;Joon Yong Bae,&nbsp;Changmin Kang,&nbsp;Minki Sung,&nbsp;Man Seong Park,&nbsp;Sung Han Kim","doi":"10.3947/ic.2021.0046","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Coronavirus disease 2019 (COVID-19) outbreaks occur in hospitals in many parts of the world. In hospital settings, the possibility of airborne transmission needs to be investigated thoroughly.</p><p><strong>Materials and methods: </strong>There was a nosocomial outbreak of COVID-19 in a hematologic ward in a tertiary hospital, Seoul, Korea. We found 11 patients and guardians with COVID-19 through vigorous contact tracing and closed-circuit television monitoring. We found one patient who probably had acquired COVID-19 through airborne-transmission. We performed airflow investigation with simulation software, whole-genome sequencing of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).</p><p><strong>Results: </strong>Of the nine individuals with COVID-19 who had been in the hematologic ward, six stayed in one multi-patient room (Room 36), and other three stayed in different rooms (Room 1, 34, 35). Guardian in room 35 was close contact to cases in room 36, and patient in room 34 used the shared bathroom for teeth brushing 40 minutes after index used. Airflow simulation revealed that air was spread from the bathroom to the adjacent room 1 while patient in room 1 did not used the shared bathroom. Airflow was associated with poor ventilation in shared bathroom due to dysfunctioning air-exhaust, grill on the door of shared bathroom and the unintended negative pressure of adjacent room.</p><p><strong>Conclusion: </strong>Transmission of SARS-CoV-2 in the hematologic ward occurred rapidly in the multi-patient room and shared bathroom settings. In addition, there was a case of possible airborne transmission due to unexpected airflow.</p>","PeriodicalId":520645,"journal":{"name":"Infection & chemotherapy","volume":" ","pages":"332-341"},"PeriodicalIF":2.9000,"publicationDate":"2021-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/d7/04/ic-53-332.PMC8258301.pdf","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Infection & chemotherapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3947/ic.2021.0046","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

Background: Coronavirus disease 2019 (COVID-19) outbreaks occur in hospitals in many parts of the world. In hospital settings, the possibility of airborne transmission needs to be investigated thoroughly.

Materials and methods: There was a nosocomial outbreak of COVID-19 in a hematologic ward in a tertiary hospital, Seoul, Korea. We found 11 patients and guardians with COVID-19 through vigorous contact tracing and closed-circuit television monitoring. We found one patient who probably had acquired COVID-19 through airborne-transmission. We performed airflow investigation with simulation software, whole-genome sequencing of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2).

Results: Of the nine individuals with COVID-19 who had been in the hematologic ward, six stayed in one multi-patient room (Room 36), and other three stayed in different rooms (Room 1, 34, 35). Guardian in room 35 was close contact to cases in room 36, and patient in room 34 used the shared bathroom for teeth brushing 40 minutes after index used. Airflow simulation revealed that air was spread from the bathroom to the adjacent room 1 while patient in room 1 did not used the shared bathroom. Airflow was associated with poor ventilation in shared bathroom due to dysfunctioning air-exhaust, grill on the door of shared bathroom and the unintended negative pressure of adjacent room.

Conclusion: Transmission of SARS-CoV-2 in the hematologic ward occurred rapidly in the multi-patient room and shared bathroom settings. In addition, there was a case of possible airborne transmission due to unexpected airflow.

Abstract Image

Abstract Image

Abstract Image

某血液科病房内新型冠状病毒感染的院内暴发
背景:2019冠状病毒病(COVID-19)疫情在世界许多地区的医院发生。在医院环境中,需要彻底调查空气传播的可能性。材料与方法:韩国首尔某三级医院血液科病房发生院内疫情。通过密切接触者追踪和闭路电视监测,共发现11例新冠肺炎患者及监护人。我们发现了一名可能通过空气传播感染COVID-19的患者。利用模拟软件进行气流调查,对SARS-CoV-2进行全基因组测序。结果:在血液科病房的9名COVID-19患者中,6人住在一个多病房(36室),另外3人住在不同的房间(1、34、35室)。35室监护人员与36室病例有密切接触,34室患者在使用指标40分钟后使用共用浴室刷牙。气流模拟显示,空气从浴室扩散到相邻的1号房间,而1号房间的患者没有使用共用浴室。由于排风功能不正常、共用浴室门上的格栅以及相邻房间的意外负压,气流与共用浴室的通风不良有关。结论:SARS-CoV-2在血液科病房的传播在多病房和共用浴室环境中迅速发生。此外,还有一个由于意外气流可能通过空气传播的案例。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书