Controlled Attenuation Parameter in Healthy Individuals Aged 8-70 Years.

IF 1.3 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Ultrasound International Open Pub Date : 2021-04-01 Epub Date: 2021-05-04 DOI:10.1055/a-1461-4714
Anders Batman Mjelle, Anesa Mulabecirovic, Edda Jonina Olafsdottir, Odd Helge Gilja, Roald Flesland Havre, Mette Vesterhus
{"title":"Controlled Attenuation Parameter in Healthy Individuals Aged 8-70 Years.","authors":"Anders Batman Mjelle,&nbsp;Anesa Mulabecirovic,&nbsp;Edda Jonina Olafsdottir,&nbsp;Odd Helge Gilja,&nbsp;Roald Flesland Havre,&nbsp;Mette Vesterhus","doi":"10.1055/a-1461-4714","DOIUrl":null,"url":null,"abstract":"Abstract Purpose Controlled attenuation parameter (CAP) is a non-invasive method to assess the presence of liver steatosis. It has been evaluated in children and adults, mainly in either the obese or in subjects with suspected liver disease. Our aim was to describe CAP in healthy non-obese subjects without suspected liver steatosis and to suggest cutoff levels for steatosis. Materials and Methods We prospectively recruited 187 individuals aged 8–70 years. All underwent clinical examination, including height and weight measurement. Body mass index (BMI) was calculated and converted into z-scores. To exclude liver pathology, B-mode ultrasound and liver stiffness measurements were performed in all prior to CAP measurement. Blood was drawn for liver biochemistry in adults. Results CAP was associated with BMI z-score across all ages. CAP started to rise alongside BMI z-score already in subjects with a BMI below average. CAP values were higher in adults than in children (p<0.001), and higher in adult males than adult females (p=0.014). CAP did not correlate with age within the adult or pediatric cohorts. CAP was highly correlated with the fatty liver index. 18 and 23% of subjects showed CAP above the suggested cutoff value for children and adults, respectively. Conclusion CAP was correlated with BMI z-score, even in individuals with a below-average BMI . We found CAP above published cutoff values in a substantial proportion of presumably healthy, non-obese children and adults, warranting further research to clarify whether this represents non-obese non-alcoholic fatty liver disease or if reference values need adjustment.","PeriodicalId":44852,"journal":{"name":"Ultrasound International Open","volume":"7 1","pages":"E6-E13"},"PeriodicalIF":1.3000,"publicationDate":"2021-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1055/a-1461-4714","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound International Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/a-1461-4714","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/5/4 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 1

Abstract

Abstract Purpose Controlled attenuation parameter (CAP) is a non-invasive method to assess the presence of liver steatosis. It has been evaluated in children and adults, mainly in either the obese or in subjects with suspected liver disease. Our aim was to describe CAP in healthy non-obese subjects without suspected liver steatosis and to suggest cutoff levels for steatosis. Materials and Methods We prospectively recruited 187 individuals aged 8–70 years. All underwent clinical examination, including height and weight measurement. Body mass index (BMI) was calculated and converted into z-scores. To exclude liver pathology, B-mode ultrasound and liver stiffness measurements were performed in all prior to CAP measurement. Blood was drawn for liver biochemistry in adults. Results CAP was associated with BMI z-score across all ages. CAP started to rise alongside BMI z-score already in subjects with a BMI below average. CAP values were higher in adults than in children (p<0.001), and higher in adult males than adult females (p=0.014). CAP did not correlate with age within the adult or pediatric cohorts. CAP was highly correlated with the fatty liver index. 18 and 23% of subjects showed CAP above the suggested cutoff value for children and adults, respectively. Conclusion CAP was correlated with BMI z-score, even in individuals with a below-average BMI . We found CAP above published cutoff values in a substantial proportion of presumably healthy, non-obese children and adults, warranting further research to clarify whether this represents non-obese non-alcoholic fatty liver disease or if reference values need adjustment.

Abstract Image

Abstract Image

Abstract Image

8-70岁健康人群的控制衰减参数
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Ultrasound International Open
Ultrasound International Open RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
3.00
自引率
0.00%
发文量
7
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信