[An integrated approach for better contamination control in hospital settings].

Igiene e sanita pubblica Pub Date : 2021-01-01
R Bosco, S Gambelli, V Urbano, G Cevenini, G Messina
{"title":"[An integrated approach for better contamination control in hospital settings].","authors":"R Bosco,&nbsp;S Gambelli,&nbsp;V Urbano,&nbsp;G Cevenini,&nbsp;G Messina","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Disinfection of hospital environments is a cornerstone of intervention strategies to reduce the risk of hospital-associated infections. Many studies show that standard cleaning procedures are not sufficient for proper disinfection of hospital environments and that the addition of no-touch technologies, such us ultraviolet light, can provide deeper sanitisation. This study aims to test whether the application of ultraviolet light after standard procedures improves hygiene levels in the shortest possible time and shows the degree of contamination before and after irradiation. A cross-sectional study was conducted in a real clinical setting in rehabilitation rooms of a contracted clinic \"Rugani Hospital\" in Monteriggioni (SI), Italy, between December 2019 and August 2020.the study was carried out according to the following protocol: i) quantization of contamination of 12 selected target points in room; ii) attribution to the points of a probability of contamination risk; iii) sampling of a subset of 6 points with probabilistic assignment; iv) evaluation of the pre-post disinfection environmental hygiene using a UV-C system. For the pre-post statistical analysis the non-parametric Wilcoxon test was used; the multivariate MANOVA was used to verify the role of different confounders, with post hoc Bonferroni test. Probabilistic calculations minimised the samplings required to conclude that the application of the ultraviolet light device reduced the level of contamination in a statistically significant manner (p &lt; 0.01) when comparing pre- and post-exposure, with less irradiation time than indicated by the manufacturer.</p>","PeriodicalId":73329,"journal":{"name":"Igiene e sanita pubblica","volume":"77 1","pages":"404-413"},"PeriodicalIF":0.0000,"publicationDate":"2021-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Igiene e sanita pubblica","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Disinfection of hospital environments is a cornerstone of intervention strategies to reduce the risk of hospital-associated infections. Many studies show that standard cleaning procedures are not sufficient for proper disinfection of hospital environments and that the addition of no-touch technologies, such us ultraviolet light, can provide deeper sanitisation. This study aims to test whether the application of ultraviolet light after standard procedures improves hygiene levels in the shortest possible time and shows the degree of contamination before and after irradiation. A cross-sectional study was conducted in a real clinical setting in rehabilitation rooms of a contracted clinic "Rugani Hospital" in Monteriggioni (SI), Italy, between December 2019 and August 2020.the study was carried out according to the following protocol: i) quantization of contamination of 12 selected target points in room; ii) attribution to the points of a probability of contamination risk; iii) sampling of a subset of 6 points with probabilistic assignment; iv) evaluation of the pre-post disinfection environmental hygiene using a UV-C system. For the pre-post statistical analysis the non-parametric Wilcoxon test was used; the multivariate MANOVA was used to verify the role of different confounders, with post hoc Bonferroni test. Probabilistic calculations minimised the samplings required to conclude that the application of the ultraviolet light device reduced the level of contamination in a statistically significant manner (p < 0.01) when comparing pre- and post-exposure, with less irradiation time than indicated by the manufacturer.

[在医院环境中更好地控制污染的综合方法]。
医院环境消毒是降低医院相关感染风险的干预策略的基石。许多研究表明,标准的清洁程序不足以对医院环境进行适当的消毒,增加非接触式技术,如紫外线,可以提供更深层次的消毒。本研究旨在测试在标准程序后使用紫外线是否能在最短的时间内提高卫生水平,并显示辐照前后的污染程度。2019年12月至2020年8月,在意大利蒙特里久尼(SI)的合同诊所“鲁加尼医院”的康复室的真实临床环境中进行了一项横断面研究。研究按照以下方案进行:i)对室内选定的12个目标点进行污染量化;Ii)归属于污染风险的某一概率点;Iii)用概率分配对6个点的子集进行抽样;iv)使用UV-C系统评价消毒前后的环境卫生。前后统计分析采用非参数Wilcoxon检验;采用多变量方差分析,采用事后Bonferroni检验,验证不同混杂因素的作用。概率计算减少了所需的采样,从而得出结论,紫外灯装置的应用以统计显著的方式降低了污染水平(p <0.01),辐照时间比制造商所指示的要短。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信