The importance of manual white blood cell differential counts and platelet estimates in elephant hematology: blood film review is essential.

IF 7.9 2区 农林科学 Q1 VETERINARY SCIENCES
Tatiana C Weisbrod, Ramiro Isaza, Carolyn Cray, Laurie Adler, Nicole I Stacy
{"title":"The importance of manual white blood cell differential counts and platelet estimates in elephant hematology: blood film review is essential.","authors":"Tatiana C Weisbrod,&nbsp;Ramiro Isaza,&nbsp;Carolyn Cray,&nbsp;Laurie Adler,&nbsp;Nicole I Stacy","doi":"10.1080/01652176.2020.1867329","DOIUrl":null,"url":null,"abstract":"<p><p>Unique features of elephant hematology are known challenges in analytical methodology like two types of monocytes typical for members of the Order Afrotheria and platelet counts of the comparatively small elephant platelet. To investigate WBC differential and platelet data generated by an impedance-based hematology analyzer without availability of validated species-specific software for recognition of elephant WBCs and platelets, compared to manual blood film review. Blood samples preserved in ethylenediaminetetraacetic acid (EDTA) of 50 elephants (n = 35 <i>Elephas maximus</i> and n = 15 <i>Loxodonta africana</i>) were used. A Mann-Whitney test for independent samples was used to compare parameters between methods and agreement was tested using Bland-Altman bias plots. All hematological variables, including absolute numbers of heterophils, lymphocytes, monocytes, eosinophils, basophils, and platelets, were significantly different (<i>p</i> < 0.0001) between both methods of analysis, and there was no agreement using Bland-Altman bias plots. Manual review consistently produced higher heterophil and monocyte counts as well as platelet estimates, while the automated analyzer produced higher lymphocyte, eosinophil, and basophil counts. The hematology analyzer did not properly differentiate elephant lymphocytes and monocytes, and did not accurately count elephant platelets. These findings emphasize the importance of manual blood film review as part of elephant complete blood counts in both clinical and research settings and as a basis for the development of hematological reference intervals.</p>","PeriodicalId":51207,"journal":{"name":"Veterinary Quarterly","volume":"41 1","pages":"30-35"},"PeriodicalIF":7.9000,"publicationDate":"2021-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/01652176.2020.1867329","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Quarterly","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1080/01652176.2020.1867329","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 2

Abstract

Unique features of elephant hematology are known challenges in analytical methodology like two types of monocytes typical for members of the Order Afrotheria and platelet counts of the comparatively small elephant platelet. To investigate WBC differential and platelet data generated by an impedance-based hematology analyzer without availability of validated species-specific software for recognition of elephant WBCs and platelets, compared to manual blood film review. Blood samples preserved in ethylenediaminetetraacetic acid (EDTA) of 50 elephants (n = 35 Elephas maximus and n = 15 Loxodonta africana) were used. A Mann-Whitney test for independent samples was used to compare parameters between methods and agreement was tested using Bland-Altman bias plots. All hematological variables, including absolute numbers of heterophils, lymphocytes, monocytes, eosinophils, basophils, and platelets, were significantly different (p < 0.0001) between both methods of analysis, and there was no agreement using Bland-Altman bias plots. Manual review consistently produced higher heterophil and monocyte counts as well as platelet estimates, while the automated analyzer produced higher lymphocyte, eosinophil, and basophil counts. The hematology analyzer did not properly differentiate elephant lymphocytes and monocytes, and did not accurately count elephant platelets. These findings emphasize the importance of manual blood film review as part of elephant complete blood counts in both clinical and research settings and as a basis for the development of hematological reference intervals.

Abstract Image

Abstract Image

人工白细胞差异计数和血小板估计在大象血液学中的重要性:血片回顾是必不可少的。
大象血液学的独特特征是已知的分析方法上的挑战,如非洲兽目成员典型的两种类型的单核细胞和相对较小的大象血小板计数。研究基于阻抗的血液学分析仪产生的白细胞差异和血小板数据,该分析仪没有有效的物种特异性软件来识别大象的白细胞和血小板,并与手工血膜检查进行比较。用乙二胺四乙酸(EDTA)保存了50头大象(35头大象和15头非洲象)的血液样本。使用独立样本的Mann-Whitney检验来比较方法之间的参数,并使用Bland-Altman偏差图来检验一致性。所有血液学变量,包括嗜白细胞、淋巴细胞、单核细胞、嗜酸性粒细胞、嗜碱性粒细胞和血小板的绝对数量,均有显著差异(p
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Quarterly
Veterinary Quarterly VETERINARY SCIENCES-
CiteScore
13.10
自引率
1.60%
发文量
18
审稿时长
>24 weeks
期刊介绍: Veterinary Quarterly is an international open access journal which publishes high quality review articles and original research in the field of veterinary science and animal diseases. The journal publishes research on a range of different animal species and topics including: - Economically important species such as domesticated and non-domesticated farm animals, including avian and poultry diseases; - Companion animals (dogs, cats, horses, pocket pets and exotics); - Wildlife species; - Infectious diseases; - Diagnosis; - Treatment including pharmacology and vaccination
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信