Logic of Selecting Suitable Dissolution Parameters in New Drug Formulations Based on A BCS Approach.

Raúl Medina-López, Edgar E Arregui, Edson J Aranda, Luis A Moreno-Rocha, Marcela Hurtado, Helgi Jung-Cook, Sally A Helmy
{"title":"Logic of Selecting Suitable Dissolution Parameters in New Drug Formulations Based on A BCS Approach.","authors":"Raúl Medina-López,&nbsp;Edgar E Arregui,&nbsp;Edson J Aranda,&nbsp;Luis A Moreno-Rocha,&nbsp;Marcela Hurtado,&nbsp;Helgi Jung-Cook,&nbsp;Sally A Helmy","doi":"10.22037/ijpr.2020.1100993","DOIUrl":null,"url":null,"abstract":"<p><p>Since the biopharmaceutical quality of generic drug formulations depends on the quality of the reference products and also information about the <i>in-vitro</i> release performance of drugs under different conditions is scarce in the literature, a dissolution study of four reference tablets was performed. Each drug was representative of one Class of the Biopharmaceutical Classification System. The <i>in-vitro</i> release performance of propranolol-HCl, carbamazepine, ranitidine-HCl, and metronidazole was evaluated using a USP basket and paddle apparatus at different agitation rates (50, 75, and 100 rpm) with two doses of each drug. In all experiments, pharmacopeial dissolution media was used and the samples were taken with automatic equipment at specific times up to 60 min, except for propranolol-HCl, for which the samples were taken up to 30 min. The dissolution profiles were compared by model-independent, model-dependent, and ANOVA-based comparisons. The three methods of data comparison showed that low <i>vs</i>. high doses were significantly different (<i>P <</i> 0.05), which may influence cases in which biowaivers of propranolol-HCl and ranitidine-HCl are requested. Additionally, the results showed that despite different hydrodynamic environments produced by the basket and paddle apparatus, under certain conditions, both types of equipment generated comparable <i>in-vitro</i> results. Variables such as the dose, agitation rate, and type of dissolution apparatus are important factors to consider in designing dissolution tests for drug products. This information can be used to test a new dosage when there is no pharmacopeial method available to perform a dissolution study. Further researches on the <i>in-vitro</i> release performance of reference drug products are required.</p>","PeriodicalId":416671,"journal":{"name":"Iranian Journal of Pharmaceutical Research : IJPR","volume":" ","pages":"465-486"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7462499/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Pharmaceutical Research : IJPR","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22037/ijpr.2020.1100993","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Since the biopharmaceutical quality of generic drug formulations depends on the quality of the reference products and also information about the in-vitro release performance of drugs under different conditions is scarce in the literature, a dissolution study of four reference tablets was performed. Each drug was representative of one Class of the Biopharmaceutical Classification System. The in-vitro release performance of propranolol-HCl, carbamazepine, ranitidine-HCl, and metronidazole was evaluated using a USP basket and paddle apparatus at different agitation rates (50, 75, and 100 rpm) with two doses of each drug. In all experiments, pharmacopeial dissolution media was used and the samples were taken with automatic equipment at specific times up to 60 min, except for propranolol-HCl, for which the samples were taken up to 30 min. The dissolution profiles were compared by model-independent, model-dependent, and ANOVA-based comparisons. The three methods of data comparison showed that low vs. high doses were significantly different (P < 0.05), which may influence cases in which biowaivers of propranolol-HCl and ranitidine-HCl are requested. Additionally, the results showed that despite different hydrodynamic environments produced by the basket and paddle apparatus, under certain conditions, both types of equipment generated comparable in-vitro results. Variables such as the dose, agitation rate, and type of dissolution apparatus are important factors to consider in designing dissolution tests for drug products. This information can be used to test a new dosage when there is no pharmacopeial method available to perform a dissolution study. Further researches on the in-vitro release performance of reference drug products are required.

Abstract Image

Abstract Image

Abstract Image

基于BCS法的新药制剂溶出度参数选择逻辑
由于仿制药制剂的生物制药质量取决于参比制剂的质量,且文献中关于药物在不同条件下的体外释放性能的信息较少,因此对四种参比片进行了溶出度研究。每种药物代表生物制药分类系统的一个类别。采用USP篮和桨形装置,对盐酸心得安、卡马西平、盐酸雷尼替丁和甲硝唑在不同搅拌速率(50、75和100 rpm)下的体外释放性能进行了评价。在所有实验中,除盐酸普萘洛尔外,均使用药典溶出介质,并在特定时间内用自动设备取样,取样时间最长为60分钟。通过模型无关、模型相关和基于方差分析的比较来比较溶出谱。三种方法的数据比较显示,低剂量与高剂量差异有统计学意义(p0.05),这可能影响到需要盐酸心得洛尔和盐酸雷尼替丁生物放弃的病例。此外,结果表明,尽管篮式和桨式装置产生的水动力环境不同,但在一定条件下,两种设备产生的体外结果相当。在设计药品溶出度试验时,诸如剂量、搅拌速率和溶出器类型等变量是需要考虑的重要因素。当没有药典方法可用于溶出度研究时,该信息可用于测试新剂量。标准药物的体外释放性能有待进一步研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书