SIMPLE 3.0. Stream single-particle cryo-EM analysis in real time

IF 3.5 Q2 BIOCHEMISTRY & MOLECULAR BIOLOGY
Joseph Caesar , Cyril F. Reboul , Chiara Machello , Simon Kiesewetter , Molly L. Tang , Justin C. Deme , Steven Johnson , Dominika Elmlund , Susan M. Lea , Hans Elmlund
{"title":"SIMPLE 3.0. Stream single-particle cryo-EM analysis in real time","authors":"Joseph Caesar ,&nbsp;Cyril F. Reboul ,&nbsp;Chiara Machello ,&nbsp;Simon Kiesewetter ,&nbsp;Molly L. Tang ,&nbsp;Justin C. Deme ,&nbsp;Steven Johnson ,&nbsp;Dominika Elmlund ,&nbsp;Susan M. Lea ,&nbsp;Hans Elmlund","doi":"10.1016/j.yjsbx.2020.100040","DOIUrl":null,"url":null,"abstract":"<div><p>We here introduce the third major release of the SIMPLE (Single-particle IMage Processing Linux Engine) open-source software package for analysis of cryogenic transmission electron microscopy (cryo-EM) movies of single-particles (Single-Particle Analysis, SPA). Development of SIMPLE 3.0 has been focused on real-time data processing using minimal CPU computing resources to allow easy and cost-efficient scaling of processing as data rates escalate. Our stream SPA tool implements the steps of anisotropic motion correction and CTF estimation, rapid template-based particle identification and 2D clustering with automatic class rejection. SIMPLE 3.0 additionally features an easy-to-use web-based graphical user interface (GUI) that can be run on any device (workstation, laptop, tablet or phone) and supports a remote multi-user environment over the network. The new project-based execution model automatically records the executed workflow and represents it as a flow diagram in the GUI. This facilitates meta-data handling and greatly simplifies usage. Using SIMPLE 3.0, it is possible to automatically obtain a clean SP data set amenable to high-resolution 3D reconstruction directly upon completion of the data acquisition, without the need for extensive image processing post collection. Only minimal standard CPU computing resources are required to keep up with a rate of ∼300 Gatan K3 direct electron detector movies per hour. SIMPLE 3.0 is available for download from simplecryoem.com.</p></div>","PeriodicalId":17238,"journal":{"name":"Journal of Structural Biology: X","volume":"4 ","pages":"Article 100040"},"PeriodicalIF":3.5000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.yjsbx.2020.100040","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Structural Biology: X","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S259015242030026X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"BIOCHEMISTRY & MOLECULAR BIOLOGY","Score":null,"Total":0}
引用次数: 8

Abstract

We here introduce the third major release of the SIMPLE (Single-particle IMage Processing Linux Engine) open-source software package for analysis of cryogenic transmission electron microscopy (cryo-EM) movies of single-particles (Single-Particle Analysis, SPA). Development of SIMPLE 3.0 has been focused on real-time data processing using minimal CPU computing resources to allow easy and cost-efficient scaling of processing as data rates escalate. Our stream SPA tool implements the steps of anisotropic motion correction and CTF estimation, rapid template-based particle identification and 2D clustering with automatic class rejection. SIMPLE 3.0 additionally features an easy-to-use web-based graphical user interface (GUI) that can be run on any device (workstation, laptop, tablet or phone) and supports a remote multi-user environment over the network. The new project-based execution model automatically records the executed workflow and represents it as a flow diagram in the GUI. This facilitates meta-data handling and greatly simplifies usage. Using SIMPLE 3.0, it is possible to automatically obtain a clean SP data set amenable to high-resolution 3D reconstruction directly upon completion of the data acquisition, without the need for extensive image processing post collection. Only minimal standard CPU computing resources are required to keep up with a rate of ∼300 Gatan K3 direct electron detector movies per hour. SIMPLE 3.0 is available for download from simplecryoem.com.

Abstract Image

简单的3.0。实时流单粒子低温电镜分析
我们在此介绍SIMPLE(单粒子图像处理Linux引擎)开源软件包的第三个主要版本,用于分析单粒子的低温透射电子显微镜(cro - em)电影(Single-particle analysis, SPA)。SIMPLE 3.0的开发一直专注于使用最小的CPU计算资源进行实时数据处理,以便随着数据速率的提升而轻松且经济地扩展处理。我们的流SPA工具实现了各向异性运动校正和CTF估计,快速基于模板的粒子识别和自动分类剔除的二维聚类步骤。SIMPLE 3.0还具有易于使用的基于web的图形用户界面(GUI),可以在任何设备(工作站,笔记本电脑,平板电脑或手机)上运行,并支持通过网络的远程多用户环境。新的基于项目的执行模型自动记录执行的工作流,并将其表示为GUI中的流程图。这有助于元数据处理,并大大简化了使用。使用SIMPLE 3.0,可以在数据采集完成后直接自动获得适合高分辨率三维重建的干净SP数据集,而无需进行大量的图像处理后采集。仅需要最小的标准CPU计算资源就可以跟上每小时300 Gatan K3直接电子探测器电影的速度。SIMPLE 3.0可从simplecryoem.com下载。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Structural Biology: X
Journal of Structural Biology: X Biochemistry, Genetics and Molecular Biology-Structural Biology
CiteScore
6.50
自引率
0.00%
发文量
20
审稿时长
62 days
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信