Effect of ceramic material type on the fracture load of inlay-retained and full-coverage fixed dental prostheses.

Biomaterial investigations in dentistry Pub Date : 2020-03-30 eCollection Date: 2020-01-01 DOI:10.1080/26415275.2020.1744443
Hamid Kermanshah, Fariba Motevasselian, Saeedeh Alavi Kakhaki, Mutlu Özcan
{"title":"Effect of ceramic material type on the fracture load of inlay-retained and full-coverage fixed dental prostheses.","authors":"Hamid Kermanshah,&nbsp;Fariba Motevasselian,&nbsp;Saeedeh Alavi Kakhaki,&nbsp;Mutlu Özcan","doi":"10.1080/26415275.2020.1744443","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> Ceramic inlay-retained fixed partial denture (IRFPD) is a conservative prosthetic option but the mechanical durability of new high strength zirconia reinforced glass ceramic FPDs is not investigated. The purpose of this study was to compare fracture load of 3-unit ceramic FPDs. <b>Materials and methods:</b> Extracted premolars and molars (<i>N</i> = 64) were used to create three test groups (IRFPDs) and one control group (full coverage FPD) (<i>n</i> = 8). The teeth were embedded in PMMA resin with a mesiodistal distance of 6 mm. Premolars had a distal and molars had a mesial inlay preparation (width: 3 mm; height: 4 mm) in the test groups. IRFPDs were made from a zirconia reinforced lithium silicate (VS) or a monolithic zirconia. Zirconia IRFPDs received 2 types of surface treatments: sandblasting (Zr-IRFPD) or internal coating with feldspathic porcelain (ZrC-IRFPD). Control group was made from monolithic zirconia with the same connector size and zirconia surfaces were sandblasted (Zr-FPD). All restorations were cemented using a resin luting cement. After 5000 thermo-cycles, fracture load values (N) were determined with a universal testing machine at a crosshead speed of 0.75 mm/min. Data were analyzed using 1-way ANOVA and Tukey`s post hoc test (<i>p ˂</i> .05). <b>Result:</b> Fracture load (mean ± SD) of Zr-FPDs, Zr-IRFPDs and ZrC-IRFPDs were 672 ± 183, 672 ± 123 and 638 ± 59, respectively, being not statistically different (<i>p</i> > .05). VS-IRFPD exhibited statically lower values (391 ± 136). The predominant mode of failure was fracture at the connector area in all groups. <b>Conclusion:</b> The fracture load of 3-unit IRFPD was significantly affected by types of ceramics but the retainer design and surface treatment in Zr groups did not show a significant effect.</p>","PeriodicalId":72378,"journal":{"name":"Biomaterial investigations in dentistry","volume":"7 1","pages":"62-70"},"PeriodicalIF":0.0000,"publicationDate":"2020-03-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/26415275.2020.1744443","citationCount":"8","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomaterial investigations in dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/26415275.2020.1744443","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2020/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 8

Abstract

Objective: Ceramic inlay-retained fixed partial denture (IRFPD) is a conservative prosthetic option but the mechanical durability of new high strength zirconia reinforced glass ceramic FPDs is not investigated. The purpose of this study was to compare fracture load of 3-unit ceramic FPDs. Materials and methods: Extracted premolars and molars (N = 64) were used to create three test groups (IRFPDs) and one control group (full coverage FPD) (n = 8). The teeth were embedded in PMMA resin with a mesiodistal distance of 6 mm. Premolars had a distal and molars had a mesial inlay preparation (width: 3 mm; height: 4 mm) in the test groups. IRFPDs were made from a zirconia reinforced lithium silicate (VS) or a monolithic zirconia. Zirconia IRFPDs received 2 types of surface treatments: sandblasting (Zr-IRFPD) or internal coating with feldspathic porcelain (ZrC-IRFPD). Control group was made from monolithic zirconia with the same connector size and zirconia surfaces were sandblasted (Zr-FPD). All restorations were cemented using a resin luting cement. After 5000 thermo-cycles, fracture load values (N) were determined with a universal testing machine at a crosshead speed of 0.75 mm/min. Data were analyzed using 1-way ANOVA and Tukey`s post hoc test (p ˂ .05). Result: Fracture load (mean ± SD) of Zr-FPDs, Zr-IRFPDs and ZrC-IRFPDs were 672 ± 183, 672 ± 123 and 638 ± 59, respectively, being not statistically different (p > .05). VS-IRFPD exhibited statically lower values (391 ± 136). The predominant mode of failure was fracture at the connector area in all groups. Conclusion: The fracture load of 3-unit IRFPD was significantly affected by types of ceramics but the retainer design and surface treatment in Zr groups did not show a significant effect.

Abstract Image

Abstract Image

Abstract Image

陶瓷材料类型对嵌体保留与全覆盖固定义齿断裂载荷的影响。
目的:陶瓷嵌体-固位固定局部义齿(IRFPD)是一种保守的义齿选择,但目前还没有对新型高强度氧化锆增强玻璃陶瓷固位义齿的机械耐久性进行研究。本研究的目的是比较3单元陶瓷fpd的断裂载荷。材料与方法:将取出的前磨牙和磨牙(N = 64)分为3个试验组(irfpd)和1个对照组(N = 8)。采用PMMA树脂包埋,中、远端距离为6mm。前磨牙有一个远端,磨牙有一个近端嵌体准备(宽度:3毫米;高度:4mm)。IRFPDs由氧化锆增强硅酸锂(VS)或单片氧化锆制成。氧化锆irfpd采用喷砂(Zr-IRFPD)和长石瓷(ZrC-IRFPD)两种表面处理方式。对照组由相同连接器尺寸的单片氧化锆制成,氧化锆表面喷砂(Zr-FPD)。所有修复体均使用树脂粘接水泥进行胶结。5000次热循环后,在十字速度为0.75 mm/min的情况下,用万能试验机测定断裂载荷值(N)。数据分析采用单因素方差分析和Tukey事后检验(p小于0.05)。结果:Zr-FPDs、Zr-IRFPDs和ZrC-IRFPDs的骨折载荷(平均±SD)分别为672±183、672±123和638±59,差异无统计学意义(p > 0.05)。VS-IRFPD静态值较低(391±136)。在所有组中,主要的失效模式是连接区域的断裂。结论:陶瓷种类对3单元IRFPD的断裂载荷有显著影响,但Zr组固位器设计和表面处理对其影响不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
审稿时长
14 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信