{"title":"Voltammetric Determination of Cysteine (2-amino-3-mercaptopropanoic acid, CySH) by Means of 4,4'-biphenol as a Homogeneous Mediator.","authors":"Mehrnoush Kamali, Zeinab Pourghobadi","doi":"10.22037/ijpr.2019.1100829","DOIUrl":null,"url":null,"abstract":"<p><p>In the present research, 4,4'-biphenol was used as a homogeneous mediator for determining cysteine (CySH) on a Glassy Carbon Electrode (GCE). To describe the electrochemical properties of 4,4'-biphenol and to examine its electrocatalytic impacts on cysteine oxidation, both Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) were employed. Our findings revealed that 4,4'-biphenol could significantly accelerate the reactions related to electron transfer to CySH. Moreover, the diffusion coefficient of CySH and its reaction with the catalytic constant of 4,4'-diphenoquinone was estimated via chronoamperometry technique. The results showed that cysteine concentration range of 10-1000 μM led to linear increases in the oxidation peaks, thus to providing a detection of 0.99 μM with R² = 0.993. A Relative Standard Deviation (RSD) of 2.5% was achieved after performing 7 cysteine replicates (100 μM), and CySH was successfully determined in real serum samples through the proposed approach.</p>","PeriodicalId":416671,"journal":{"name":"Iranian Journal of Pharmaceutical Research : IJPR","volume":" ","pages":"1725-1734"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7059032/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Pharmaceutical Research : IJPR","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22037/ijpr.2019.1100829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
In the present research, 4,4'-biphenol was used as a homogeneous mediator for determining cysteine (CySH) on a Glassy Carbon Electrode (GCE). To describe the electrochemical properties of 4,4'-biphenol and to examine its electrocatalytic impacts on cysteine oxidation, both Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) were employed. Our findings revealed that 4,4'-biphenol could significantly accelerate the reactions related to electron transfer to CySH. Moreover, the diffusion coefficient of CySH and its reaction with the catalytic constant of 4,4'-diphenoquinone was estimated via chronoamperometry technique. The results showed that cysteine concentration range of 10-1000 μM led to linear increases in the oxidation peaks, thus to providing a detection of 0.99 μM with R² = 0.993. A Relative Standard Deviation (RSD) of 2.5% was achieved after performing 7 cysteine replicates (100 μM), and CySH was successfully determined in real serum samples through the proposed approach.