Voltammetric Determination of Cysteine (2-amino-3-mercaptopropanoic acid, CySH) by Means of 4,4'-biphenol as a Homogeneous Mediator.

Mehrnoush Kamali, Zeinab Pourghobadi
{"title":"Voltammetric Determination of Cysteine (2-amino-3-mercaptopropanoic acid, CySH) by Means of 4,4'-biphenol as a Homogeneous Mediator.","authors":"Mehrnoush Kamali,&nbsp;Zeinab Pourghobadi","doi":"10.22037/ijpr.2019.1100829","DOIUrl":null,"url":null,"abstract":"<p><p>In the present research, 4,4'-biphenol was used as a homogeneous mediator for determining cysteine (CySH) on a Glassy Carbon Electrode (GCE). To describe the electrochemical properties of 4,4'-biphenol and to examine its electrocatalytic impacts on cysteine oxidation, both Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) were employed. Our findings revealed that 4,4'-biphenol could significantly accelerate the reactions related to electron transfer to CySH. Moreover, the diffusion coefficient of CySH and its reaction with the catalytic constant of 4,4'-diphenoquinone was estimated via chronoamperometry technique. The results showed that cysteine concentration range of 10-1000 μM led to linear increases in the oxidation peaks, thus to providing a detection of 0.99 μM with R² = 0.993. A Relative Standard Deviation (RSD) of 2.5% was achieved after performing 7 cysteine replicates (100 μM), and CySH was successfully determined in real serum samples through the proposed approach.</p>","PeriodicalId":416671,"journal":{"name":"Iranian Journal of Pharmaceutical Research : IJPR","volume":" ","pages":"1725-1734"},"PeriodicalIF":0.0000,"publicationDate":"2019-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7059032/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Pharmaceutical Research : IJPR","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.22037/ijpr.2019.1100829","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

In the present research, 4,4'-biphenol was used as a homogeneous mediator for determining cysteine (CySH) on a Glassy Carbon Electrode (GCE). To describe the electrochemical properties of 4,4'-biphenol and to examine its electrocatalytic impacts on cysteine oxidation, both Cyclic Voltammetry (CV) and Linear Sweep Voltammetry (LSV) were employed. Our findings revealed that 4,4'-biphenol could significantly accelerate the reactions related to electron transfer to CySH. Moreover, the diffusion coefficient of CySH and its reaction with the catalytic constant of 4,4'-diphenoquinone was estimated via chronoamperometry technique. The results showed that cysteine concentration range of 10-1000 μM led to linear increases in the oxidation peaks, thus to providing a detection of 0.99 μM with R² = 0.993. A Relative Standard Deviation (RSD) of 2.5% was achieved after performing 7 cysteine replicates (100 μM), and CySH was successfully determined in real serum samples through the proposed approach.

Abstract Image

Abstract Image

Abstract Image

以4,4′-双酚为均相介质伏安法测定半胱氨酸(2-氨基-3-巯基丙酸,CySH)。
在本研究中,4,4'-双酚作为均匀介质在玻碳电极(GCE)上测定半胱氨酸(CySH)。采用循环伏安法(CV)和线性扫描伏安法(LSV)描述了4,4′-双酚的电化学性质并考察了其对半胱氨酸氧化的电催化作用。结果表明,4,4′-双酚能显著加速电子向CySH转移的相关反应。此外,通过计时电流法测定了CySH的扩散系数及其与4,4′-二苯醌催化常数的反应。结果表明,当半胱氨酸浓度在10 ~ 1000 μM范围内时,氧化峰呈线性增加,检测范围为0.99 μM, R²= 0.993。在进行7次半胱氨酸重复(100 μM)后,相对标准偏差(RSD)为2.5%,并通过该方法成功测定了真实血清样品中的CySH。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书