Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT.

Q3 Medicine
Vishnukumar Rajaraman, Madhusudhanan Ponnusamy, Dhanapathi Halanaik
{"title":"Size specific dose estimate (SSDE) for estimating patient dose from CT used in myocardial perfusion SPECT/CT.","authors":"Vishnukumar Rajaraman,&nbsp;Madhusudhanan Ponnusamy,&nbsp;Dhanapathi Halanaik","doi":"10.22038/aojnmb.2019.40863.1276","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE and CTDIvol, when AEC is used.</p><p><strong>Methods: </strong>CT data of consecutively selected 111 patients were included for analysis. CTDIvol values of the CT scans were extracted for each patient. Effective diameter of each patient was calculated as geometric mean of anteroposterior and lateral diameters measured on axial CT images. Corresponding conversion factors for effective diameters were obtained from American Association of Physicists in Medicine (AAPM) report 204. SSDE was obtained as the product of CTDIvol and conversion factor values. Linear regression model was used to evaluate the relationship between patient size and the parameters SSDE and CTDIvol.</p><p><strong>Results: </strong>Mean weight was 62 (11.5) and range was 34 - 103 kg. Median CTDIvol (mGy) on AEC mode was 7.27(IQ range 7.27, 7.65) and mean effective diameter was 26.2 cm (2.4). Mean SSDE (mGy) was 10.6 (0.84). Good positive correlation was obtained between CTDIvol and effective diameter (r=0.536; p<0.0005). Strong inverse correlation was noted between SSDE and effective diameter (r=-0.777; p<0.0005). Linear regression model for establishing relationship between CTDIvol and effective diameter showed slope of 0.314mGy/cm (R=0.561; R2=0.314; P<0.0005) whereas between effective diameter and SSDE slope was -0.23mGy/cm (R=0.676; R2=0.457; P< 0.0005).</p><p><strong>Conclusion: </strong>The study shows that CTDIvol and SSDE vary but divergently, with patient size. SSDE is a better estimate of patient radiation dose from CT of MPI SPECT/CT than CTDIvol in systems that use automated exposure control.</p>","PeriodicalId":8503,"journal":{"name":"Asia Oceania Journal of Nuclear Medicine and Biology","volume":"8 1","pages":"58-63"},"PeriodicalIF":0.0000,"publicationDate":"2020-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6994783/pdf/","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asia Oceania Journal of Nuclear Medicine and Biology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/aojnmb.2019.40863.1276","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 4

Abstract

Objectives: Size specific dose estimate (SSDE) is a new parameter that includes patient size factor in its calculation. Recent studies have produced mixed results on the utility of SSDE, especially when automatic exposure control (AEC) was used. The objective of the study was to find out if there is a relationship between patient size and each of the parameters, SSDE and CTDIvol, when AEC is used.

Methods: CT data of consecutively selected 111 patients were included for analysis. CTDIvol values of the CT scans were extracted for each patient. Effective diameter of each patient was calculated as geometric mean of anteroposterior and lateral diameters measured on axial CT images. Corresponding conversion factors for effective diameters were obtained from American Association of Physicists in Medicine (AAPM) report 204. SSDE was obtained as the product of CTDIvol and conversion factor values. Linear regression model was used to evaluate the relationship between patient size and the parameters SSDE and CTDIvol.

Results: Mean weight was 62 (11.5) and range was 34 - 103 kg. Median CTDIvol (mGy) on AEC mode was 7.27(IQ range 7.27, 7.65) and mean effective diameter was 26.2 cm (2.4). Mean SSDE (mGy) was 10.6 (0.84). Good positive correlation was obtained between CTDIvol and effective diameter (r=0.536; p<0.0005). Strong inverse correlation was noted between SSDE and effective diameter (r=-0.777; p<0.0005). Linear regression model for establishing relationship between CTDIvol and effective diameter showed slope of 0.314mGy/cm (R=0.561; R2=0.314; P<0.0005) whereas between effective diameter and SSDE slope was -0.23mGy/cm (R=0.676; R2=0.457; P< 0.0005).

Conclusion: The study shows that CTDIvol and SSDE vary but divergently, with patient size. SSDE is a better estimate of patient radiation dose from CT of MPI SPECT/CT than CTDIvol in systems that use automated exposure control.

Abstract Image

Abstract Image

Abstract Image

大小比剂量估计(SSDE)用于估计心肌灌注SPECT/CT中CT的患者剂量。
目的:体积比剂量估算(SSDE)是一种将患者体积因素纳入计算的新参数。最近的研究对SSDE的效用产生了不同的结果,特别是当使用自动暴露控制(AEC)时。该研究的目的是发现当使用AEC时,患者大小与每个参数(SSDE和CTDIvol)之间是否存在关系。方法:连续选取111例患者的CT资料进行分析。提取每位患者CT扫描的CTDIvol值。每个患者的有效直径计算为轴向CT图像测量的正位和侧位直径的几何平均值。相应的有效直径换算因子来自美国医学物理学家协会(AAPM)报告204。SSDE是CTDIvol和转换因子值的乘积。采用线性回归模型评价患者大小与SSDE、CTDIvol参数的关系。结果:平均体重62(11.5),范围34 ~ 103 kg。AEC模式下CTDIvol (mGy)中位数为7.27(IQ范围7.27,7.65),平均有效直径26.2 cm(2.4)。平均SSDE (mGy)为10.6(0.84)。CTDIvol与有效直径呈正相关(r=0.536;结论:研究显示CTDIvol和SSDE随患者体型不同而不同。在使用自动暴露控制的系统中,SSDE比CTDIvol更能估计MPI SPECT/CT的患者辐射剂量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Asia Oceania Journal of Nuclear Medicine and Biology
Asia Oceania Journal of Nuclear Medicine and Biology Medicine-Radiology, Nuclear Medicine and Imaging
CiteScore
1.80
自引率
0.00%
发文量
28
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信