Intraobserver and interobserver reliability of computed tomography measurements of the soft palate in French bulldogs.

IF 1.3 Q2 VETERINARY SCIENCES
Veterinary Record Open Pub Date : 2019-12-18 eCollection Date: 2019-01-01 DOI:10.1136/vetreco-2019-000373
Pauline Deprez, Iban Irubetagoyena, Jean-Guillaume Grand, Nathaniel Harran
{"title":"Intraobserver and interobserver reliability of computed tomography measurements of the soft palate in French bulldogs.","authors":"Pauline Deprez,&nbsp;Iban Irubetagoyena,&nbsp;Jean-Guillaume Grand,&nbsp;Nathaniel Harran","doi":"10.1136/vetreco-2019-000373","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>CT imaging has been used to document the soft palate dimensions in brachycephalic dogs but reliability of such measurements has not been evaluated. The aims of this study were to propose a method of measurements of the soft palate in French bulldogs and determine its reliability.</p><p><strong>Methods: </strong>Thirty French bulldogs were prospectively included. Five measurements of the soft palate were performed on soft tissue and bone window mid-sagittal images: length, thickness at 25, 50 and 75 per cent of its length and sagittal plane cross-sectional area. Three sets of data were separately acquired by three observers. Intraobserver and interobserver reliability for all measurements was assessed using intraclass correlation coefficient (ICC).</p><p><strong>Results: </strong>The median ICCs showed excellent reliability (0.90 to 0.99) for all intraobserver measurements except for thickness at 75 per cent which showed good (0.80 to 0.89) to excellent reliability. The median ICC showed excellent reliability for all interobserver measurements.</p><p><strong>Conclusion: </strong>The soft palate measurements on a single CT image are reproducible and repeatable. Further study is needed to assess the reliability of these measurements in the same patient with different endotracheal tube positions.</p>","PeriodicalId":23565,"journal":{"name":"Veterinary Record Open","volume":"6 1","pages":"e000373"},"PeriodicalIF":1.3000,"publicationDate":"2019-12-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1136/vetreco-2019-000373","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Record Open","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1136/vetreco-2019-000373","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 1

Abstract

Background: CT imaging has been used to document the soft palate dimensions in brachycephalic dogs but reliability of such measurements has not been evaluated. The aims of this study were to propose a method of measurements of the soft palate in French bulldogs and determine its reliability.

Methods: Thirty French bulldogs were prospectively included. Five measurements of the soft palate were performed on soft tissue and bone window mid-sagittal images: length, thickness at 25, 50 and 75 per cent of its length and sagittal plane cross-sectional area. Three sets of data were separately acquired by three observers. Intraobserver and interobserver reliability for all measurements was assessed using intraclass correlation coefficient (ICC).

Results: The median ICCs showed excellent reliability (0.90 to 0.99) for all intraobserver measurements except for thickness at 75 per cent which showed good (0.80 to 0.89) to excellent reliability. The median ICC showed excellent reliability for all interobserver measurements.

Conclusion: The soft palate measurements on a single CT image are reproducible and repeatable. Further study is needed to assess the reliability of these measurements in the same patient with different endotracheal tube positions.

Abstract Image

Abstract Image

Abstract Image

法国斗牛犬软腭计算机断层测量的观察者内和观察者间可靠性。
背景:CT成像已被用于记录短头犬的软腭尺寸,但这种测量的可靠性尚未得到评估。本研究的目的是提出一种测量法国斗牛犬软腭的方法,并确定其可靠性。方法:前瞻性纳入30只法国斗牛犬。在软组织和骨窗中矢状面图像上进行了软腭的五种测量:长度,厚度在其长度的25%,50%和75%,矢状面截面积。三个观测者分别获得了三组数据。使用类内相关系数(ICC)评估所有测量的观察者内部和观察者之间的信度。结果:除厚度为75%外,所有观察者内测量的中位icc显示出良好(0.80至0.89)至优异的信度(0.90至0.99)。中位ICC对所有观察者间测量结果显示出极好的可靠性。结论:单张CT图像对软腭的测量具有再现性和可重复性。需要进一步的研究来评估这些测量在同一患者不同气管插管位置的可靠性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Record Open
Veterinary Record Open VETERINARY SCIENCES-
CiteScore
3.00
自引率
0.00%
发文量
25
审稿时长
19 weeks
期刊介绍: Veterinary Record Open is a journal dedicated to publishing specialist veterinary research across a range of topic areas including those of a more niche and specialist nature to that considered in the weekly Vet Record. Research from all disciplines of veterinary interest will be considered. It is an Open Access journal of the British Veterinary Association.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信