Correction of Excessive Tibial Plateau Angle and Limb Shortening in a Juvenile Dog Using a Hinged Circular Fixator Construct and Distraction Osteogenesis.

Q3 Veterinary
Case Reports in Veterinary Medicine Pub Date : 2019-11-16 eCollection Date: 2019-01-01 DOI:10.1155/2019/1439237
Daniel D Lewis, Stanley E Kim, Justin Shmalberg, Sandra L MacArthur
{"title":"Correction of Excessive Tibial Plateau Angle and Limb Shortening in a Juvenile Dog Using a Hinged Circular Fixator Construct and Distraction Osteogenesis.","authors":"Daniel D Lewis,&nbsp;Stanley E Kim,&nbsp;Justin Shmalberg,&nbsp;Sandra L MacArthur","doi":"10.1155/2019/1439237","DOIUrl":null,"url":null,"abstract":"<p><p>An 18-week-old Rhodesian Ridgeback puppy that was hit by a car sustained a Salter-Harris type III fracture of the left proximal tibial physis and ipsilateral diaphyseal femoral and tibial fractures. The diaphyseal fractures were successfully stabilized with bone plate fixation. Premature closure of the caudal aspect of the proximal tibial physis, secondary to the proximal physeal fracture, resulted in an excessively high tibial plateau angle (TPA) of 50° with a limb length discrepancy of 13% by 24 weeks of age. The deformity was addressed by performing a proximal tibial osteotomy and subsequent distraction osteogenesis to reduce the TPA while concurrently lengthening the crus. A radial osteotomy was performed in the proximal metaphyseal region and the hinged fixator was applied. Distraction was initiated the day following surgery at a rate of 1 mm per day as measured along the caudal cortex of the tibia with a rhythm of three distractions daily. Distraction was terminated 19 days postoperatively. Sequential distraction of the osteotomy resulted in 17 mm of tibial lengthening and a final TPA of 3°. The fixator was removed 52 days after application. Complications included wire tract inflammation involving the wires securing the proximal segment and a calcaneal fracture which required bone plate stabilization. The left pelvic limb was only 8% shorter than the right pelvic limb and the dog had only a subtle lameness 12 months after surgery. The hinged circular fixator construct allowed for both the reduction of the TPA and limb segment lengthening in this dog.</p>","PeriodicalId":37339,"journal":{"name":"Case Reports in Veterinary Medicine","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2019-11-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/1439237","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Case Reports in Veterinary Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2019/1439237","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"Veterinary","Score":null,"Total":0}
引用次数: 1

Abstract

An 18-week-old Rhodesian Ridgeback puppy that was hit by a car sustained a Salter-Harris type III fracture of the left proximal tibial physis and ipsilateral diaphyseal femoral and tibial fractures. The diaphyseal fractures were successfully stabilized with bone plate fixation. Premature closure of the caudal aspect of the proximal tibial physis, secondary to the proximal physeal fracture, resulted in an excessively high tibial plateau angle (TPA) of 50° with a limb length discrepancy of 13% by 24 weeks of age. The deformity was addressed by performing a proximal tibial osteotomy and subsequent distraction osteogenesis to reduce the TPA while concurrently lengthening the crus. A radial osteotomy was performed in the proximal metaphyseal region and the hinged fixator was applied. Distraction was initiated the day following surgery at a rate of 1 mm per day as measured along the caudal cortex of the tibia with a rhythm of three distractions daily. Distraction was terminated 19 days postoperatively. Sequential distraction of the osteotomy resulted in 17 mm of tibial lengthening and a final TPA of 3°. The fixator was removed 52 days after application. Complications included wire tract inflammation involving the wires securing the proximal segment and a calcaneal fracture which required bone plate stabilization. The left pelvic limb was only 8% shorter than the right pelvic limb and the dog had only a subtle lameness 12 months after surgery. The hinged circular fixator construct allowed for both the reduction of the TPA and limb segment lengthening in this dog.

Abstract Image

Abstract Image

Abstract Image

使用铰链圆形固定架和牵张成骨术矫正幼年犬胫骨平台角度过大和肢体缩短。
一只18周大的罗得西亚脊背犬被汽车撞到,左侧胫骨近端骨折,同侧股骨骨干骨折和胫骨骨折。骨干骨折经钢板固定成功稳定。继发于胫骨近端骨骺骨折的胫骨近端骨骺尾侧过早闭合,导致胫骨平台角(TPA)过高,达50°,24周龄时肢体长度差异达13%。畸形是通过胫骨近端截骨术和随后的牵张成骨术来解决的,以减少TPA,同时延长小腿。在近端干骺端行桡骨截骨术,并应用铰链固定架。手术后第一天开始以每天1毫米的速度沿胫骨尾侧皮质测量,每天有三次分心的节奏。术后19天停止牵张。截骨术的连续牵张导致胫骨延长17mm,最终TPA为3°。应用后52天取出固定物。并发症包括金属丝束炎症,累及固定近段的金属丝和需要固定骨板的跟骨骨折。左骨盆肢只比右骨盆肢短8%,手术后12个月,狗只有轻微的跛行。铰接圆形固定架结构允许TPA的复位和肢体节段的延长。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Case Reports in Veterinary Medicine
Case Reports in Veterinary Medicine Veterinary-Veterinary (all)
CiteScore
0.70
自引率
0.00%
发文量
14
审稿时长
13 weeks
期刊介绍: Case Reports in Veterinary Medicine is a peer-reviewed, Open Access journal that publishes case reports and case series in all areas of veterinary medicine.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信