Is every-day walking in older adults more analogous to dual-task walking or to usual walking? Elucidating the gaps between gait performance in the lab and during 24/7 monitoring.

IF 3.5
Inbar Hillel, Eran Gazit, Alice Nieuwboer, Laura Avanzino, Lynn Rochester, Andrea Cereatti, Ugo Della Croce, Marcel Olde Rikkert, Bastiaan R Bloem, Elisa Pelosin, Silvia Del Din, Pieter Ginis, Nir Giladi, Anat Mirelman, Jeffrey M Hausdorff
{"title":"Is every-day walking in older adults more analogous to dual-task walking or to usual walking? Elucidating the gaps between gait performance in the lab and during 24/7 monitoring.","authors":"Inbar Hillel,&nbsp;Eran Gazit,&nbsp;Alice Nieuwboer,&nbsp;Laura Avanzino,&nbsp;Lynn Rochester,&nbsp;Andrea Cereatti,&nbsp;Ugo Della Croce,&nbsp;Marcel Olde Rikkert,&nbsp;Bastiaan R Bloem,&nbsp;Elisa Pelosin,&nbsp;Silvia Del Din,&nbsp;Pieter Ginis,&nbsp;Nir Giladi,&nbsp;Anat Mirelman,&nbsp;Jeffrey M Hausdorff","doi":"10.1186/s11556-019-0214-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The traditional evaluation of gait in the laboratory during structured testing has provided important insights, but is limited by its \"snapshot\" character and observation in an unnatural environment. Wearables enable monitoring of gait in real-world environments over a week. Initial findings show that in-lab and real-world measures differ. As a step towards better understanding these gaps, we directly compared in-lab usual-walking (UW) and dual-task walking (DTW) to daily-living measures of gait.</p><p><strong>Methods: </strong>In-lab gait features (e.g., gait speed, step regularity, and stride regularity) derived from UW and DTW were compared to the same gait features during daily-living in 150 elderly fallers (age: 76.5 ± 6.3 years, 37.6% men). In both settings, features were extracted from a lower-back accelerometer. In the real-world setting, subjects were asked to wear the device for 1 week and pre-processing detected 30-s daily-living walking bouts. A histogram of all walking bouts was determined for each walking feature for each subject and then each subject's typical (percentile 50, median), worst (percentile 10) and the best (percentile 90) values over the week were determined for each feature. Statistics of reliability were assessed using Intra-Class correlations and Bland-Altman plots.</p><p><strong>Results: </strong>As expected, in-lab gait speed, step regularity, and stride regularity were worse during DTW, compared to UW. In-lab gait speed, step regularity, and stride regularity during UW were significantly higher (i.e., better) than the typical daily-living values (<i>p</i> < 0.001) and different (<i>p</i> < 0.001) from the worst and best values. DTW values tended to be similar to typical daily-living values (<i>p</i> = 0.205, <i>p</i> = 0.053, <i>p</i> = 0.013 respectively). ICC assessment and Bland-Altman plots indicated that in-lab values do not reliably reflect the daily-walking values.</p><p><strong>Conclusions: </strong>Gait values measured during relatively long (30-s) daily-living walking bouts are more similar to the corresponding values obtained in the lab during dual-task walking, as compared to usual walking. Still, gait performance during most daily-living walking bouts is worse than that measured during usual and dual-tasking in the lab. The values measured in the lab do not reliably reflect daily-living measures. That is, an older adult's typical daily-living gait cannot be estimated by simply measuring walking in a structured, laboratory setting.</p>","PeriodicalId":520622,"journal":{"name":"European review of aging and physical activity : official journal of the European Group for Research into Elderly and Physical Activity","volume":" ","pages":"6"},"PeriodicalIF":3.5000,"publicationDate":"2019-05-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s11556-019-0214-5","citationCount":"130","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"European review of aging and physical activity : official journal of the European Group for Research into Elderly and Physical Activity","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s11556-019-0214-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 130

Abstract

Background: The traditional evaluation of gait in the laboratory during structured testing has provided important insights, but is limited by its "snapshot" character and observation in an unnatural environment. Wearables enable monitoring of gait in real-world environments over a week. Initial findings show that in-lab and real-world measures differ. As a step towards better understanding these gaps, we directly compared in-lab usual-walking (UW) and dual-task walking (DTW) to daily-living measures of gait.

Methods: In-lab gait features (e.g., gait speed, step regularity, and stride regularity) derived from UW and DTW were compared to the same gait features during daily-living in 150 elderly fallers (age: 76.5 ± 6.3 years, 37.6% men). In both settings, features were extracted from a lower-back accelerometer. In the real-world setting, subjects were asked to wear the device for 1 week and pre-processing detected 30-s daily-living walking bouts. A histogram of all walking bouts was determined for each walking feature for each subject and then each subject's typical (percentile 50, median), worst (percentile 10) and the best (percentile 90) values over the week were determined for each feature. Statistics of reliability were assessed using Intra-Class correlations and Bland-Altman plots.

Results: As expected, in-lab gait speed, step regularity, and stride regularity were worse during DTW, compared to UW. In-lab gait speed, step regularity, and stride regularity during UW were significantly higher (i.e., better) than the typical daily-living values (p < 0.001) and different (p < 0.001) from the worst and best values. DTW values tended to be similar to typical daily-living values (p = 0.205, p = 0.053, p = 0.013 respectively). ICC assessment and Bland-Altman plots indicated that in-lab values do not reliably reflect the daily-walking values.

Conclusions: Gait values measured during relatively long (30-s) daily-living walking bouts are more similar to the corresponding values obtained in the lab during dual-task walking, as compared to usual walking. Still, gait performance during most daily-living walking bouts is worse than that measured during usual and dual-tasking in the lab. The values measured in the lab do not reliably reflect daily-living measures. That is, an older adult's typical daily-living gait cannot be estimated by simply measuring walking in a structured, laboratory setting.

Abstract Image

Abstract Image

Abstract Image

老年人的日常行走是更类似于双重任务行走还是更类似于日常行走?阐明实验室和24/7监测期间步态表现之间的差距。
背景:在结构化测试期间,传统的实验室步态评估提供了重要的见解,但受到其“快照”特征和在非自然环境中的观察的限制。可穿戴设备可以在一周内监测现实环境中的步态。最初的研究结果表明,实验室和现实世界的测量结果不同。为了更好地理解这些差距,我们直接将实验室中正常行走(UW)和双任务行走(DTW)与日常生活步态测量进行了比较。方法:将150例老年跌倒者(年龄:76.5±6.3岁,男性37.6%)的实验室步态特征(如步态速度、步幅规律、步幅规律)与日常生活中相同的步态特征进行比较。在这两种情况下,特征都是从下背部加速度计中提取的。在现实环境中,受试者被要求佩戴该设备1周,并进行预处理,检测到30秒的日常生活步行。对每个受试者的每个行走特征绘制出所有行走次数的直方图,然后确定每个受试者一周内每个特征的典型值(百分位数50,中位数)、最差值(百分位数10)和最佳值(百分位数90)。信度统计使用Intra-Class相关性和Bland-Altman图进行评估。结果:正如预期的那样,DTW期间的实验室步态速度、步骤规律性和步幅规律性比UW更差。在实验室中,UW期间的步态速度、步伐规律性和步幅规律性显著高于(即优于)典型的日常生活值(p p分别= 0.205、p = 0.053和p = 0.013)。ICC评估和Bland-Altman图表明,实验室值不能可靠地反映日常步行值。结论:与正常行走相比,在较长时间(30秒)的日常生活行走中测量的步态值与在实验室中获得的双任务行走的相应值更相似。尽管如此,在大多数日常生活步行比赛中的步态表现比在实验室中进行常规和双重任务时的步态表现更差。在实验室测量的值不能可靠地反映日常生活的测量。也就是说,老年人典型的日常生活步态不能通过简单地在实验室环境中测量步行来估计。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书