Fracture Resistance of CAD/CAM Lithium Disilicate of Endodontically Treated Mandibular Damaged Molars Based on Different Preparation Designs.

IF 3 Q3 MATERIALS SCIENCE, BIOMATERIALS
International Journal of Biomaterials Pub Date : 2019-05-12 eCollection Date: 2019-01-01 DOI:10.1155/2019/2475297
Carolina Clausson, Cristiano Clausson Schroeder, Paulo Vicenti Goloni, Flavio Artur Rego Farias, Leandro Passos, Raquel Virgínia Zanetti
{"title":"Fracture Resistance of CAD/CAM Lithium Disilicate of Endodontically Treated Mandibular Damaged Molars Based on Different Preparation Designs.","authors":"Carolina Clausson,&nbsp;Cristiano Clausson Schroeder,&nbsp;Paulo Vicenti Goloni,&nbsp;Flavio Artur Rego Farias,&nbsp;Leandro Passos,&nbsp;Raquel Virgínia Zanetti","doi":"10.1155/2019/2475297","DOIUrl":null,"url":null,"abstract":"<p><p>The aim of this study was to evaluate the fracture resistance of 2 different types of all-ceramic crown using immediate dentin sealing (IDS), obtained using a CAD/CAM system on molars with different preparations. Forty extracted lower molars were endodontically treated and divided into four groups (n = 10) according to the dental preparation. Group 1 (SP0) was prepared without filling the pulp chamber and crown-root junction was located at the cementoenamel junction (CEJ). Group 2 (SP1) was prepared without filling the pulp chamber and crown-root junction was located 1-mm above the CEJ. Groups 3 and 4 contained a flat preparation surface with no axial wall height. Group 3 (CP0) was made IDS with complete filling of the pulp chamber with composite resin and crown-root junction was located at the CEJ. Group 4 (CP1) was prepared with complete filling of the pulp chamber and crown-root junction was located 1-mm above the CEJ. All groups were restored with CAD/CAM lithium disilicate ceramic crowns. Specimens were subjected to the fracture test and statistically analyzed using analysis of variance (ANOVA). Fracture mode was determined using a stereoscopic microscope, classified as repairable or nonrepairable, and analyzed using Fischer's exact test. Results indicated that there were no significant differences between the groups in terms of fracture resistance or fracture pattern (p >0.05). Fracture resistance was the lowest in the SP0 group, followed by the SP1 group (1634.38 N) of CP0 (1821.50 N), and it was the highest in the CP1 group. There was a predominance of nonrepairable fractures and there were no significant differences in the fracture resistance and fracture mode of CAD/CAM lithium disilicate molar all-ceramic crowns. Endodontically treated molars teeth might be restored with endocrowns or all-ceramic crowns on flat preparation; however tooth fracture failures that affect reliability of these types of restorations should be considered.</p>","PeriodicalId":13704,"journal":{"name":"International Journal of Biomaterials","volume":"2019 ","pages":"2475297"},"PeriodicalIF":3.0000,"publicationDate":"2019-05-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2019/2475297","citationCount":"4","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Biomaterials","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2019/2475297","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2019/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"MATERIALS SCIENCE, BIOMATERIALS","Score":null,"Total":0}
引用次数: 4

Abstract

The aim of this study was to evaluate the fracture resistance of 2 different types of all-ceramic crown using immediate dentin sealing (IDS), obtained using a CAD/CAM system on molars with different preparations. Forty extracted lower molars were endodontically treated and divided into four groups (n = 10) according to the dental preparation. Group 1 (SP0) was prepared without filling the pulp chamber and crown-root junction was located at the cementoenamel junction (CEJ). Group 2 (SP1) was prepared without filling the pulp chamber and crown-root junction was located 1-mm above the CEJ. Groups 3 and 4 contained a flat preparation surface with no axial wall height. Group 3 (CP0) was made IDS with complete filling of the pulp chamber with composite resin and crown-root junction was located at the CEJ. Group 4 (CP1) was prepared with complete filling of the pulp chamber and crown-root junction was located 1-mm above the CEJ. All groups were restored with CAD/CAM lithium disilicate ceramic crowns. Specimens were subjected to the fracture test and statistically analyzed using analysis of variance (ANOVA). Fracture mode was determined using a stereoscopic microscope, classified as repairable or nonrepairable, and analyzed using Fischer's exact test. Results indicated that there were no significant differences between the groups in terms of fracture resistance or fracture pattern (p >0.05). Fracture resistance was the lowest in the SP0 group, followed by the SP1 group (1634.38 N) of CP0 (1821.50 N), and it was the highest in the CP1 group. There was a predominance of nonrepairable fractures and there were no significant differences in the fracture resistance and fracture mode of CAD/CAM lithium disilicate molar all-ceramic crowns. Endodontically treated molars teeth might be restored with endocrowns or all-ceramic crowns on flat preparation; however tooth fracture failures that affect reliability of these types of restorations should be considered.

Abstract Image

Abstract Image

CAD/CAM二硅酸锂牙髓治疗下颌损伤磨牙的抗折性研究
本研究的目的是评估2种不同类型的全瓷冠使用直接牙本质密封(IDS),通过CAD/CAM系统在不同制备的磨牙上获得的抗断裂性。对40颗拔除的下磨牙进行根管治疗,根据牙体准备情况分为4组(n = 10)。第一组(SP0)不充填牙髓腔,冠根交界处位于牙髓-牙釉质交界处(CEJ)。第2组(SP1)不填充牙髓腔,冠根交界处位于CEJ上方1mm处。第3组和第4组为无轴壁高度的平坦制备面。第3组(CP0)采用复合树脂充填髓腔,冠根交界处位于CEJ。第4组(CP1)牙髓腔充填完全,冠根交界处位于CEJ上方1mm处。所有组均采用CAD/CAM二硅酸锂陶瓷冠修复。标本进行断裂试验,并使用方差分析(ANOVA)进行统计分析。使用立体显微镜确定断裂模式,将其分类为可修复或不可修复,并使用Fischer精确检验进行分析。结果显示,两组间抗骨折性及骨折形态差异无统计学意义(p >0.05)。SP0组骨折阻力最小,CP0 (1821.50 N) SP1组次之(1634.38 N), CP1组最高。CAD/CAM二硅酸锂磨牙全瓷冠的抗折性和断裂方式差异无统计学意义。根管治疗后的磨牙可以用内冠或全陶瓷冠在平面上修复;然而,牙断裂失效影响这些类型修复的可靠性应予以考虑。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International Journal of Biomaterials
International Journal of Biomaterials MATERIALS SCIENCE, BIOMATERIALS-
CiteScore
4.30
自引率
3.20%
发文量
50
审稿时长
21 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信