{"title":"[Evaluation of Immature Platelet Fraction Measurements Using an Automated Hematology Analyzer, Sysmex XN].","authors":"Naoyuki Yoshikawa, Akiko Masuda, Masahiro Jona, Shigeo Okubo, Yasuhito Nannya, Hiromitsu Yokota, Mineo Kurokawa, Yutaka Yatomi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The immature platelet fraction (IPF%) is a parameter for the automatic quantification of reticulated plate- lets and is considered to reflect platelet production. We evaluated IPF% measurements using an automated analyzer, the Sysmex XN. We measured the platelet counts and the IPF% values in 35 healthy subjects and 275 patients with various diseases using both the XN analyzer and a conventional analyzer, the Sysmex XE. Significant correlations in the platelet count and the IPF% were observed between the XN results and the XE results. In the same samples, significant inverse correlations were observed between the platelet count and the IPF% in both the XN and XE results. The coefficient of variation values for the platelet count and the IPF% measurements obtained using the XN analyzer were lower than those obtained using the XE ana- lyzer. In patients who had undergone hematopoietic stem cell transplantation, the IPF% measurements obtained using the XN analyzer increased several days before platelet recovery. IPF% measurements performed using the XN analyzer are adequate for clinical use. This parameter may be a useful marker for the prediction of platelet recovery. [Original].</p>","PeriodicalId":21457,"journal":{"name":"Rinsho byori. The Japanese journal of clinical pathology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2016-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho byori. The Japanese journal of clinical pathology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
The immature platelet fraction (IPF%) is a parameter for the automatic quantification of reticulated plate- lets and is considered to reflect platelet production. We evaluated IPF% measurements using an automated analyzer, the Sysmex XN. We measured the platelet counts and the IPF% values in 35 healthy subjects and 275 patients with various diseases using both the XN analyzer and a conventional analyzer, the Sysmex XE. Significant correlations in the platelet count and the IPF% were observed between the XN results and the XE results. In the same samples, significant inverse correlations were observed between the platelet count and the IPF% in both the XN and XE results. The coefficient of variation values for the platelet count and the IPF% measurements obtained using the XN analyzer were lower than those obtained using the XE ana- lyzer. In patients who had undergone hematopoietic stem cell transplantation, the IPF% measurements obtained using the XN analyzer increased several days before platelet recovery. IPF% measurements performed using the XN analyzer are adequate for clinical use. This parameter may be a useful marker for the prediction of platelet recovery. [Original].