{"title":"Improving the emission intensity of laser-induced breakdown spectroscopy by tip discharge of a Tesla coil","authors":"Qiuyun Wang, Weijie Dang, Yuanfei Jiang, Anmin Chen and Mingxing Jin","doi":"10.1039/D2JA00015F","DOIUrl":null,"url":null,"abstract":"<p >This study combined Tesla coil discharge with laser-induced breakdown spectroscopy (TCD-LIBS) to improve the spectral intensity of Cu plasmas. The Tesla coil used a transformer to enhance an ordinary voltage, and then discharged from the discharge terminal of the secondary coil. A DC voltage of 24 V was converted into a high-frequency AC voltage of thousands of volts by the Tesla coil. The voltage, frequency, energy, and current of the generated high voltage AC discharge were 1.66 kV, 1.35 MHz, 24 W, and 14.5 mA. First, the effect of the discharge distance (the discharge tip to the sample surface) on the line intensity was optimized, revealing that the spectral emission of TCD-LIBS was stronger in the distance range from 4 mm to 8 mm. Secondly, the effect of laser energy on the spectral emission with or without discharge was investigated. The spectral intensity can be increased by about 40 times using Tesla coil discharge. Finally, the electron temperature and density of TCD-LIBS were obtained, revealing that the two parameters can be increased by about 1.6 and 1.4 times using Tesla coil discharge. Because the Tesla coil has high spectral enhancement efficiency and safety, the combination of Tesla coil discharge and LIBS is conducive to the development of the LIBS analysis field.</p>","PeriodicalId":81,"journal":{"name":"Journal of Analytical Atomic Spectrometry","volume":" 5","pages":" 994-999"},"PeriodicalIF":3.3000,"publicationDate":"2022-03-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Analytical Atomic Spectrometry","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2022/ja/d2ja00015f","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

This study combined Tesla coil discharge with laser-induced breakdown spectroscopy (TCD-LIBS) to improve the spectral intensity of Cu plasmas. The Tesla coil used a transformer to enhance an ordinary voltage, and then discharged from the discharge terminal of the secondary coil. A DC voltage of 24 V was converted into a high-frequency AC voltage of thousands of volts by the Tesla coil. The voltage, frequency, energy, and current of the generated high voltage AC discharge were 1.66 kV, 1.35 MHz, 24 W, and 14.5 mA. First, the effect of the discharge distance (the discharge tip to the sample surface) on the line intensity was optimized, revealing that the spectral emission of TCD-LIBS was stronger in the distance range from 4 mm to 8 mm. Secondly, the effect of laser energy on the spectral emission with or without discharge was investigated. The spectral intensity can be increased by about 40 times using Tesla coil discharge. Finally, the electron temperature and density of TCD-LIBS were obtained, revealing that the two parameters can be increased by about 1.6 and 1.4 times using Tesla coil discharge. Because the Tesla coil has high spectral enhancement efficiency and safety, the combination of Tesla coil discharge and LIBS is conducive to the development of the LIBS analysis field.

Abstract Image

利用特斯拉线圈尖端放电提高激光诱导击穿光谱的发射强度
本研究将特斯拉线圈放电与激光诱导击穿光谱(TCD-LIBS)相结合,以提高铜等离子体的光谱强度。特斯拉线圈利用变压器提高普通电压,然后从次级线圈的放电端子放电。24伏的直流电压通过特斯拉线圈转换成数千伏的高频交流电压。高压交流放电电压、频率、能量、电流分别为1.66 kV、1.35 MHz、24w、14.5 mA。首先,优化了放电距离(放电尖端到样品表面)对谱线强度的影响,发现在4 ~ 8 mm的距离范围内,TCD-LIBS的光谱发射更强。其次,研究了激光能量对有放电和无放电时光谱发射的影响。使用特斯拉线圈放电可使光谱强度提高约40倍。最后,得到了TCD-LIBS的电子温度和电子密度,发现使用特斯拉线圈放电可以使这两个参数分别提高约1.6倍和1.4倍。由于特斯拉线圈具有较高的光谱增强效率和安全性,因此将特斯拉线圈放电与LIBS相结合有利于LIBS分析领域的发展。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
6.20
自引率
26.50%
发文量
228
审稿时长
1.7 months
期刊介绍: Innovative research on the fundamental theory and application of spectrometric techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书