Robot-assisted ureteroureterostomy in pediatric patients: current perspectives.

Robotic surgery (Auckland) Pub Date : 2017-04-24 eCollection Date: 2017-01-01 DOI:10.2147/RSRR.S99536
Jonathan S Ellison, Thomas S Lendvay
{"title":"Robot-assisted ureteroureterostomy in pediatric patients: current perspectives.","authors":"Jonathan S Ellison,&nbsp;Thomas S Lendvay","doi":"10.2147/RSRR.S99536","DOIUrl":null,"url":null,"abstract":"<p><p>Developments in pediatric robotic surgery have increased the feasibility of minimally invasive surgery for complex urinary tract reconstruction. Ureteroureterostomy is a commonly employed strategy for the management of a duplicated ureteral system with either upper pole obstruction or lower pole vesicoureteral reflux, and this approach minimizes the risk to a healthy ureter as might be seen in a common sheath ureteral reimplant and avoids complex dissection around the renal hilum as with a heminephrectomy. The robotic platform enables optimum instrument manipulation for an end-to-side ureteral anastomosis as well as excellent visualization deep into the pelvis for excision of the distal ureteral stump. In this study, the indications and preoperative evaluation for pediatric robotic ureteroureterostomy (RUU) were described and intraoperative considerations for a successful repair were highlighted. In order to assess the outcomes, a PubMed search was performed to find the articles focusing on RUU in the pediatric population. The institutional experience of the authors was also reviewed. As with an open procedure, both minimizing dissection on the recipient ureter and ensuring a tension-free, watertight anastomosis are key principles to minimize complications. Although port placement is similar to that in robotic pyeloplasty, small adjustments may need to be made to ensure access to the pelvis. An assistant port and/or traction sutures is often used to aid in the dissection and anastomosis. RUU was first described in 2008, and several reports have demonstrated positive short-term results. However, median follow-up times are limited with most series reporting outcomes <1 year postoperatively. A future study is required to establish the long-term efficacy of this procedure and define the optimum patient population for a robotic approach.</p>","PeriodicalId":92137,"journal":{"name":"Robotic surgery (Auckland)","volume":"4 ","pages":"45-55"},"PeriodicalIF":0.0000,"publicationDate":"2017-04-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/RSRR.S99536","citationCount":"12","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Robotic surgery (Auckland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/RSRR.S99536","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 12

Abstract

Developments in pediatric robotic surgery have increased the feasibility of minimally invasive surgery for complex urinary tract reconstruction. Ureteroureterostomy is a commonly employed strategy for the management of a duplicated ureteral system with either upper pole obstruction or lower pole vesicoureteral reflux, and this approach minimizes the risk to a healthy ureter as might be seen in a common sheath ureteral reimplant and avoids complex dissection around the renal hilum as with a heminephrectomy. The robotic platform enables optimum instrument manipulation for an end-to-side ureteral anastomosis as well as excellent visualization deep into the pelvis for excision of the distal ureteral stump. In this study, the indications and preoperative evaluation for pediatric robotic ureteroureterostomy (RUU) were described and intraoperative considerations for a successful repair were highlighted. In order to assess the outcomes, a PubMed search was performed to find the articles focusing on RUU in the pediatric population. The institutional experience of the authors was also reviewed. As with an open procedure, both minimizing dissection on the recipient ureter and ensuring a tension-free, watertight anastomosis are key principles to minimize complications. Although port placement is similar to that in robotic pyeloplasty, small adjustments may need to be made to ensure access to the pelvis. An assistant port and/or traction sutures is often used to aid in the dissection and anastomosis. RUU was first described in 2008, and several reports have demonstrated positive short-term results. However, median follow-up times are limited with most series reporting outcomes <1 year postoperatively. A future study is required to establish the long-term efficacy of this procedure and define the optimum patient population for a robotic approach.

Abstract Image

Abstract Image

Abstract Image

儿童患者的机器人辅助输尿管输尿管造口术:目前的观点。
儿童机器人手术的发展增加了复杂泌尿道重建微创手术的可行性。输尿管输尿管造口术是治疗重复输尿管系统出现上极梗阻或下极膀胱输尿管反流的常用策略,这种方法可以将输尿管健康的风险降至最低,这可能是在普通输尿管鞘再植入术中看到的,并且避免了肾门周围复杂的剥离,就像半肾切除术一样。机器人平台为输尿管端侧吻合提供了最佳的器械操作,并为输尿管远端残端切除提供了深入骨盆的良好可视化。在本研究中,描述了儿童机器人输尿管输尿管造口术(RUU)的适应症和术前评估,并强调了成功修复的术中注意事项。为了评估结果,我们在PubMed上进行了搜索,以找到关注儿科人群RUU的文章。还审查了作者的机构经验。与开放手术一样,最大限度地减少对受体输尿管的剥离和确保无张力、水密吻合是减少并发症的关键原则。虽然移植位置与机器人肾盂成形术相似,但可能需要做一些小的调整以确保进入骨盆。辅助端口和/或牵引缝合线常用于辅助剥离和吻合。RUU于2008年首次被描述,一些报告显示了积极的短期效果。然而,大多数系列报告结果的中位随访时间有限
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书