Analysis of Forces Applied During Transalveolar Sinus Lift: A Preliminary Clinical Study.

3区 医学 Q1 Dentistry
Lorenzo Tavelli, Andrea Enrico Borgonovo, Andrea Ravidà, Muhammad H A Saleh, Emanuele Zappa, Tiziano Testori, Hom-Lay Wang
{"title":"Analysis of Forces Applied During Transalveolar Sinus Lift: A Preliminary Clinical Study.","authors":"Lorenzo Tavelli,&nbsp;Andrea Enrico Borgonovo,&nbsp;Andrea Ravidà,&nbsp;Muhammad H A Saleh,&nbsp;Emanuele Zappa,&nbsp;Tiziano Testori,&nbsp;Hom-Lay Wang","doi":"10.1097/ID.0000000000000817","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To introduce a novel modality that enables the measurement of forces applied during a transalveolar sinus floor elevation (tSFE) and to investigate the influence of anatomical and surgical factors on the necessitated force in sinus membrane detachment.</p><p><strong>Material and methods: </strong>A new endosinus probe, innovated with a calibrated load cell, was used to test the forces needed to perforate ten maxillary sinuses in 5 human cadavers. The same probe was also used to detach the Schneiderian membrane from the bony floor of 21 human subjects undergoing tSFE.</p><p><strong>Results: </strong>The force needed to cause membrane perforation in the cadaver sample was on average 3.46 ± 1.04 N. The maximum force applied in vivo to a sinus membrane without perforation was 2.01 ± 0.67 N on average. Regression analysis showed that smoking (P < 0.001), as well as 3.0 mm osteotomy (P < 0.001), was significantly correlated to increased forces during membrane detachment.</p><p><strong>Conclusions: </strong>The maximum force needed to detach the membrane was found to be, on average, lower than the membrane breaking load in cadavers. Furthermore, because of smoking and a 3.0-mm osteotomy diameter demonstrating a high association with increased forces during membrane detachment, they may be considered as risk factors of membrane perforation.</p>","PeriodicalId":13309,"journal":{"name":"Implant Dentistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1097/ID.0000000000000817","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Implant Dentistry","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/ID.0000000000000817","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Dentistry","Score":null,"Total":0}
引用次数: 3

Abstract

Purpose: To introduce a novel modality that enables the measurement of forces applied during a transalveolar sinus floor elevation (tSFE) and to investigate the influence of anatomical and surgical factors on the necessitated force in sinus membrane detachment.

Material and methods: A new endosinus probe, innovated with a calibrated load cell, was used to test the forces needed to perforate ten maxillary sinuses in 5 human cadavers. The same probe was also used to detach the Schneiderian membrane from the bony floor of 21 human subjects undergoing tSFE.

Results: The force needed to cause membrane perforation in the cadaver sample was on average 3.46 ± 1.04 N. The maximum force applied in vivo to a sinus membrane without perforation was 2.01 ± 0.67 N on average. Regression analysis showed that smoking (P < 0.001), as well as 3.0 mm osteotomy (P < 0.001), was significantly correlated to increased forces during membrane detachment.

Conclusions: The maximum force needed to detach the membrane was found to be, on average, lower than the membrane breaking load in cadavers. Furthermore, because of smoking and a 3.0-mm osteotomy diameter demonstrating a high association with increased forces during membrane detachment, they may be considered as risk factors of membrane perforation.

经肺泡窦提升过程中作用力分析:初步临床研究。
目的:介绍一种能够测量经肺泡窦底抬高(tSFE)过程中施加的力的新方法,并研究解剖和手术因素对窦膜脱离所需力的影响。材料和方法:采用一种新型内窦探头,创新了校准称重传感器,用于测试5具尸体上颌窦穿孔所需的力。同样的探针也被用于从21名接受tSFE的人类受试者的骨底分离施耐德膜。结果:导致尸体膜穿孔所需的力平均为3.46±1.04 N,在体内作用于未穿孔的窦膜的最大力平均为2.01±0.67 N。回归分析显示,吸烟(P < 0.001)和3.0 mm截骨(P < 0.001)与膜剥离过程中力的增加有显著相关。结论:分离膜所需的最大力平均低于尸体的破膜负荷。此外,由于吸烟和3.0 mm截骨直径与膜脱离过程中增加的力高度相关,它们可能被认为是膜穿孔的危险因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Implant Dentistry
Implant Dentistry 医学-牙科与口腔外科
CiteScore
4.00
自引率
0.00%
发文量
0
审稿时长
6-12 weeks
期刊介绍: Cessation. Implant Dentistry, an interdisciplinary forum for general practitioners, specialists, educators, and researchers, publishes relevant clinical, educational, and research articles that document current concepts of oral implantology in sections on biomaterials, clinical reports, oral and maxillofacial surgery, oral pathology, periodontics, prosthodontics, and research. The journal includes guest editorials, letters to the editor, book reviews, abstracts of current literature, and news of sponsoring societies.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信