[Clinical application of a large flow-through venous flap].

中华整形外科杂志 Pub Date : 2016-07-01
Dawei Zheng, Zhangcan Li, Guangchao Cao, Yao Wu, Rongjian Shi, Kuishui Shou
{"title":"[Clinical application of a large flow-through venous flap].","authors":"Dawei Zheng,&nbsp;Zhangcan Li,&nbsp;Guangchao Cao,&nbsp;Yao Wu,&nbsp;Rongjian Shi,&nbsp;Kuishui Shou","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To investigate the clinical effects of a large flow-through venous flap.</p><p><strong>Methods: </strong>Between January 2012 and January 2015,this flap was used in 9 patients with upper limb injury to reconstruct artery defect and large skin and soft tissue defect. The donor sites were covered with free skin grafts. The skin and soft tissue defects size ranged from 7.0 cm × 10.0 cm to 9.5 cm × 18.0 cm (average 9.2 cm× 12.0 cm).</p><p><strong>Results: </strong>The flaps size ranged from 9.0 cm × 12.0 cm-11.5 cm × 20.0 cm (average 10.3 cm × 13.5 cm).Except 2 cases of small area necrosis occurred in the distal end of the flap, which healed after dressing change; the other 7 flaps survived completely. The donor wounds healed primarily. Postoperative patients were followed up for 12-26 months (mean 14.5 months). Flap appearance, texture and thickness were similar to the surrounding normal tissue. According to the sensory function evaluation standard formulated by the British Medical Research Council in 1954,the result of skin flap sensory evaluation was assessed as S2 in two cases,S3 in four cases,S3 in three cases, with excellent and good rate as 77.8%.According to the assessment standard for upper limb function issued by Chinese Medical Association of hand surgery, the limb function were assessed as excellent in 6 cases, good in 2 cases, poor in 1 case, with the excellent and good rate as 88.9%.</p><p><strong>Conclusions: </strong>The large flowthrough venous flap has the advantages of simple operation, minimal donor site morbidity and satisfactory appearance. It is a feasible method to repair the wound at upper limb with artery defect.</p>","PeriodicalId":69147,"journal":{"name":"中华整形外科杂志","volume":"32 4","pages":"249-53"},"PeriodicalIF":0.0000,"publicationDate":"2016-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"中华整形外科杂志","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To investigate the clinical effects of a large flow-through venous flap.

Methods: Between January 2012 and January 2015,this flap was used in 9 patients with upper limb injury to reconstruct artery defect and large skin and soft tissue defect. The donor sites were covered with free skin grafts. The skin and soft tissue defects size ranged from 7.0 cm × 10.0 cm to 9.5 cm × 18.0 cm (average 9.2 cm× 12.0 cm).

Results: The flaps size ranged from 9.0 cm × 12.0 cm-11.5 cm × 20.0 cm (average 10.3 cm × 13.5 cm).Except 2 cases of small area necrosis occurred in the distal end of the flap, which healed after dressing change; the other 7 flaps survived completely. The donor wounds healed primarily. Postoperative patients were followed up for 12-26 months (mean 14.5 months). Flap appearance, texture and thickness were similar to the surrounding normal tissue. According to the sensory function evaluation standard formulated by the British Medical Research Council in 1954,the result of skin flap sensory evaluation was assessed as S2 in two cases,S3 in four cases,S3 in three cases, with excellent and good rate as 77.8%.According to the assessment standard for upper limb function issued by Chinese Medical Association of hand surgery, the limb function were assessed as excellent in 6 cases, good in 2 cases, poor in 1 case, with the excellent and good rate as 88.9%.

Conclusions: The large flowthrough venous flap has the advantages of simple operation, minimal donor site morbidity and satisfactory appearance. It is a feasible method to repair the wound at upper limb with artery defect.

大静脉血流瓣的临床应用
目的:探讨大流量静脉皮瓣的临床应用效果。方法:2012年1月~ 2015年1月,应用该皮瓣修复9例上肢动脉缺损及大面积皮肤软组织缺损。供体部位覆盖自由皮肤移植物。皮肤及软组织缺损大小为7.0 cm× 10.0 cm ~ 9.5 cm× 18.0 cm,平均为9.2 cm× 12.0 cm。结果:皮瓣大小为9.0 cm × 12.0 cm ~ 11.5 cm × 20.0 cm,平均10.3 cm × 13.5 cm。除皮瓣远端出现小面积坏死2例外,均在换药后愈合;其他7个襟翼完全存活。供体伤口基本愈合。术后随访12 ~ 26个月,平均14.5个月。皮瓣外观、质地及厚度与周围正常组织相近。根据1954年英国医学研究理事会制定的感觉功能评价标准,皮瓣感觉评价结果2例为S2, 4例为S3, 3例为S3,优良率77.8%。按照中华手外科医学会上肢功能评定标准,评定为优6例,良2例,差1例,优良率为88.9%。结论:大流量静脉瓣具有操作简单、供区并发症少、外观满意等优点。它是修复上肢动脉缺损创面的一种可行方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.20
自引率
0.00%
发文量
5346
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信