Al-Shimaa Mohamed Sabry, Heba Abd El-Kader Mansour, Tarek Helmy Abo El-Azm, Shimaa Ahmed Mostafa, Basant Samy Zahid
{"title":"Echocardiographic predictors of atrial fibrillation after mitral valve replacement","authors":"Al-Shimaa Mohamed Sabry, Heba Abd El-Kader Mansour, Tarek Helmy Abo El-Azm, Shimaa Ahmed Mostafa, Basant Samy Zahid","doi":"10.1016/j.ehj.2017.07.002","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><p>Detection of the echocardiographic predictors of post-operative atrial fibrillation in patients with rheumatic mitral valve disease undergoing mitral valve replacement.</p></div><div><h3>Methods</h3><p>The study included 50 patients with rheumatic mitral valve disease undergoing mitral valve replacement. Preoperative assessment included standard two-dimensional echocardiography to assess LA diameter, volume, and emptying fraction, LV volume and ejection fraction. TDI derived velocity, strain of the left atrium and speckle tracking to assess left ventricular function then postoperative follow up for 1<!--> <!-->month for occurrence of atrial fibrillation.</p></div><div><h3>Results</h3><p>The incidence of postoperative AF was 44%; these patients were significantly older (<em>P</em> <!-->=<!--> <!-->0.001) and show higher prevalence of DM (<em>P</em> <!-->=<!--> <!-->0.001) and HTN (<em>P</em> <!-->=<!--> <!-->0.001). Also, LA diameters (antero-posterior, transverse and longitudinal) and LA volumes (maximal and minimal) were increased (<em>P</em> <!--><<!--> <!-->0.001), but no difference in LA emptying fraction (<em>P</em> <!-->><!--> <!-->0.05). Systolic LA strain and left ventricular global longitudinal strain were significantly reduced in those patients (<em>P</em> value <0.001). Echocardiographic predictors of AF were LA systolic strain (<em>P</em> value <0.001) and LV global longitudinal strain (<em>P</em> value<!--> <!-->=<!--> <!-->0.003). Cutoff value for systolic LA strain ≤23 had sensitivity 90.91% and specificity 93.33% in predicting POAF. While, left ventricular global longitudinal strain ≤−14.9% had sensitivity 63.6% and specificity 100.0% in predicting AF.</p></div><div><h3>Conclusion</h3><p>LA systolic strain and LV global longitudinal strain were significant predictors of POAF. Echocardiographic parameters can identify patients at greater risk of developing POAF who can benefit from preventive measure and guide the selection of prosthesis.</p></div>","PeriodicalId":44962,"journal":{"name":"Egyptian Heart Journal","volume":"69 4","pages":"Pages 281-288"},"PeriodicalIF":1.4000,"publicationDate":"2017-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ehj.2017.07.002","citationCount":"9","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1110260816301338","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 9
Abstract
Objectives
Detection of the echocardiographic predictors of post-operative atrial fibrillation in patients with rheumatic mitral valve disease undergoing mitral valve replacement.
Methods
The study included 50 patients with rheumatic mitral valve disease undergoing mitral valve replacement. Preoperative assessment included standard two-dimensional echocardiography to assess LA diameter, volume, and emptying fraction, LV volume and ejection fraction. TDI derived velocity, strain of the left atrium and speckle tracking to assess left ventricular function then postoperative follow up for 1 month for occurrence of atrial fibrillation.
Results
The incidence of postoperative AF was 44%; these patients were significantly older (P = 0.001) and show higher prevalence of DM (P = 0.001) and HTN (P = 0.001). Also, LA diameters (antero-posterior, transverse and longitudinal) and LA volumes (maximal and minimal) were increased (P < 0.001), but no difference in LA emptying fraction (P > 0.05). Systolic LA strain and left ventricular global longitudinal strain were significantly reduced in those patients (P value <0.001). Echocardiographic predictors of AF were LA systolic strain (P value <0.001) and LV global longitudinal strain (P value = 0.003). Cutoff value for systolic LA strain ≤23 had sensitivity 90.91% and specificity 93.33% in predicting POAF. While, left ventricular global longitudinal strain ≤−14.9% had sensitivity 63.6% and specificity 100.0% in predicting AF.
Conclusion
LA systolic strain and LV global longitudinal strain were significant predictors of POAF. Echocardiographic parameters can identify patients at greater risk of developing POAF who can benefit from preventive measure and guide the selection of prosthesis.
期刊介绍:
The Egyptian Heart Journal is the official journal of the Egyptian Society of Cardiology. It is an international journal that publishes peer-reviewed articles on all aspects of cardiovascular disease, including original clinical studies and translational investigations. The journal publishes research, review articles, case reports and commentary articles, as well as editorials interpreting and commenting on the research presented. In addition, it provides a forum for the exchange of information on all aspects of cardiovascular medicine, including educational issues.