Value of global longitudinal strain by two dimensional speckle tracking echocardiography in predicting coronary artery disease severity

IF 1.4 Q3 CARDIAC & CARDIOVASCULAR SYSTEMS
Hanan Radwan, Ekhlas Hussein
{"title":"Value of global longitudinal strain by two dimensional speckle tracking echocardiography in predicting coronary artery disease severity","authors":"Hanan Radwan,&nbsp;Ekhlas Hussein","doi":"10.1016/j.ehj.2016.08.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Background</h3><p>Significant coronary artery stenosis might cause persistently impaired longitudinal left ventricle (LV) function at rest. LV global longitudinal strain (LVGLS) can be accurately assessed by 2D speckle-tracking strain echocardiography(2D-STE).</p></div><div><h3>Objective</h3><p>We aimed to evaluate the diagnostic accuracy of LV global longitudinal strain obtained by 2D-STE in prediction of severity of CAD.</p></div><div><h3>Methods</h3><p>Eighty patients with suspected stable angina pectoris were included. They underwent transthoracic echocardiography (TTE) to measure LV ejection fraction, 2-D-STE to measure GLS and coronary angiography (CA). The patients were divided into two groups: group 1 (58 patients) with significant (&gt;70%) CAD, and group 2 (22 patients) with non-significant (&lt;70%) CAD. Images were obtained in the apical long-axis, four-chamber, and two chamber views. Regional longitudinal systolic strain was measured in 17 myocardial segments and averaged to provide global longitudinal strain (LVGLS).</p></div><div><h3>Results</h3><p>There was significant decrease in GLS in group 1 compared to group 2 (−11.86<!--> <!-->±<!--> <!-->2.89% versus −18.65<!--> <!-->±<!--> <!-->0.79%, <em>P</em> <!-->&lt;<!--> <!-->0.000). The optimal cutoff value of GLS for prediction of significant CAD was −15.6% [AUC 0.88, 95% CI 0.78–0.96 <em>p</em> <!-->&lt;<!--> <!-->0.000]. The sensitivity, specificity and accuracy of GLS for detecting significant CAD were 93.1%, 81.8%,and 90% respectively.There was a significant positive correlation between GLS and EF (<em>r</em> <!-->=<!--> <!-->0.33; <em>p</em> <!-->=<!--> <!-->0.036).There was incremental significant decrease in GLS with increasing number of coronary vessels involved.</p></div><div><h3>Conclusion</h3><p>Measurement of global longitudinal strain using 2D speckle tracking echocardiography is sensitive and accurate tool in the prediction of severe CAD.</p></div>","PeriodicalId":44962,"journal":{"name":"Egyptian Heart Journal","volume":"69 2","pages":"Pages 95-101"},"PeriodicalIF":1.4000,"publicationDate":"2017-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/j.ehj.2016.08.001","citationCount":"37","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Egyptian Heart Journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S111026081630031X","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 37

Abstract

Background

Significant coronary artery stenosis might cause persistently impaired longitudinal left ventricle (LV) function at rest. LV global longitudinal strain (LVGLS) can be accurately assessed by 2D speckle-tracking strain echocardiography(2D-STE).

Objective

We aimed to evaluate the diagnostic accuracy of LV global longitudinal strain obtained by 2D-STE in prediction of severity of CAD.

Methods

Eighty patients with suspected stable angina pectoris were included. They underwent transthoracic echocardiography (TTE) to measure LV ejection fraction, 2-D-STE to measure GLS and coronary angiography (CA). The patients were divided into two groups: group 1 (58 patients) with significant (>70%) CAD, and group 2 (22 patients) with non-significant (<70%) CAD. Images were obtained in the apical long-axis, four-chamber, and two chamber views. Regional longitudinal systolic strain was measured in 17 myocardial segments and averaged to provide global longitudinal strain (LVGLS).

Results

There was significant decrease in GLS in group 1 compared to group 2 (−11.86 ± 2.89% versus −18.65 ± 0.79%, P < 0.000). The optimal cutoff value of GLS for prediction of significant CAD was −15.6% [AUC 0.88, 95% CI 0.78–0.96 p < 0.000]. The sensitivity, specificity and accuracy of GLS for detecting significant CAD were 93.1%, 81.8%,and 90% respectively.There was a significant positive correlation between GLS and EF (r = 0.33; p = 0.036).There was incremental significant decrease in GLS with increasing number of coronary vessels involved.

Conclusion

Measurement of global longitudinal strain using 2D speckle tracking echocardiography is sensitive and accurate tool in the prediction of severe CAD.

Abstract Image

Abstract Image

Abstract Image

二维散斑跟踪超声心动图整体纵向应变预测冠状动脉疾病严重程度的价值
背景:严重的冠状动脉狭窄可能导致静止时纵向左心室(LV)功能持续受损。二维斑点跟踪应变超声心动图(2D- ste)可准确评估左室整体纵向应变(LVGLS)。目的评价2D-STE对左室整体纵向应变预测冠心病严重程度的诊断准确性。方法选取疑似稳定型心绞痛患者80例。他们接受了经胸超声心动图(TTE)测量左室射血分数,2-D-STE测量GLS和冠状动脉造影(CA)。患者分为两组:1组(58例)有显著性(<70%) CAD, 2组(22例)无显著性(<70%) CAD。在根尖长轴、四室和两室视图中获得图像。测量17个心肌节段的局部纵向收缩应变,取平均得到全局纵向应变(LVGLS)。结果1组GLS明显低于2组(- 11.86±2.89% vs - 18.65±0.79%,P <0.000)。GLS预测显著性CAD的最佳临界值为- 15.6% [AUC 0.88, 95% CI 0.78-0.96 p <0.000]。GLS检测显著性CAD的灵敏度、特异性和准确性分别为93.1%、81.8%和90%。GLS与EF呈显著正相关(r = 0.33;p = 0.036)。随着冠状动脉受累数量的增加,GLS有显著的增加性降低。结论二维散斑跟踪超声心动图测量整体纵向应变是预测重症CAD的灵敏、准确的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Egyptian Heart Journal
Egyptian Heart Journal CARDIAC & CARDIOVASCULAR SYSTEMS-
CiteScore
2.10
自引率
0.00%
发文量
82
审稿时长
9 weeks
期刊介绍: The Egyptian Heart Journal is the official journal of the Egyptian Society of Cardiology. It is an international journal that publishes peer-reviewed articles on all aspects of cardiovascular disease, including original clinical studies and translational investigations. The journal publishes research, review articles, case reports and commentary articles, as well as editorials interpreting and commenting on the research presented. In addition, it provides a forum for the exchange of information on all aspects of cardiovascular medicine, including educational issues.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信