Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study.

IF 0.4 Q4 OPHTHALMOLOGY
Open Ophthalmology Journal Pub Date : 2018-03-13 eCollection Date: 2018-01-01 DOI:10.2174/1874364101812010019
Martin K Schmid, Livia Faes, Lucas M Bachmann, Michael A Thiel
{"title":"Accuracy of a Self-monitoring Test for Identification and Monitoring of Age-related Macular Degeneration: A Diagnostic Case-control Study.","authors":"Martin K Schmid,&nbsp;Livia Faes,&nbsp;Lucas M Bachmann,&nbsp;Michael A Thiel","doi":"10.2174/1874364101812010019","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate diagnostic accuracy of a new self-monitoring device using a Vernier hyperacuity alignment task.</p><p><strong>Method: </strong>A total of 11 wet Age-Related Macular Degeneration (AMD) patients and 9 controls contributing 37 eyes were consecutively enrolled into this prospective diagnostic case-control study at the retina centre of the Cantonal Hospital Lucerne, Switzerland. Vernier acuity testing (index test) and Optical Coherence Tomography (OCT, reference test) were performed in all participants. OCT scans were evaluated and graded by a retinal specialist masked to diagnosis and index test results. Candidate parameters of the index test to be used as the diagnostic statistic were identified using a bootstrap procedure. Ten parameters remaining were further assessed in univariate analyses. The overall Standard Deviation (SD) of absolute distances across all four axes of the Vernier acuity test provided the highest area under the Receiver Operating Characteristics (ROC) curve and was therefore selected.</p><p><strong>Results: </strong>Mean age of patients with wet AMD was 81.2 years (SD 4.99), mean numbers of letters were 67.4 (SD 14.1). The proportion of women was similar in both groups (controls: 88%, wet AMD: 72%). The area under the ROC curve was 0.87 (95% confidence interval CI: 0.75- 0.99) indicating excellent discrimination. Best accuracy was reached at a cut-off value of 0.64 with a sensitivity of 75% and a specificity of 94%.</p><p><strong>Conclusion: </strong>This diagnostic case-control study of a new screening device for AMD shows acceptable diagnostic accuracy. The promising preliminary data of this study call for further upstream evaluations in reasonably sized clinical studies.</p>","PeriodicalId":46347,"journal":{"name":"Open Ophthalmology Journal","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2018-03-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2174/1874364101812010019","citationCount":"13","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Open Ophthalmology Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2174/1874364101812010019","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2018/1/1 0:00:00","PubModel":"eCollection","JCR":"Q4","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 13

Abstract

Objective: To evaluate diagnostic accuracy of a new self-monitoring device using a Vernier hyperacuity alignment task.

Method: A total of 11 wet Age-Related Macular Degeneration (AMD) patients and 9 controls contributing 37 eyes were consecutively enrolled into this prospective diagnostic case-control study at the retina centre of the Cantonal Hospital Lucerne, Switzerland. Vernier acuity testing (index test) and Optical Coherence Tomography (OCT, reference test) were performed in all participants. OCT scans were evaluated and graded by a retinal specialist masked to diagnosis and index test results. Candidate parameters of the index test to be used as the diagnostic statistic were identified using a bootstrap procedure. Ten parameters remaining were further assessed in univariate analyses. The overall Standard Deviation (SD) of absolute distances across all four axes of the Vernier acuity test provided the highest area under the Receiver Operating Characteristics (ROC) curve and was therefore selected.

Results: Mean age of patients with wet AMD was 81.2 years (SD 4.99), mean numbers of letters were 67.4 (SD 14.1). The proportion of women was similar in both groups (controls: 88%, wet AMD: 72%). The area under the ROC curve was 0.87 (95% confidence interval CI: 0.75- 0.99) indicating excellent discrimination. Best accuracy was reached at a cut-off value of 0.64 with a sensitivity of 75% and a specificity of 94%.

Conclusion: This diagnostic case-control study of a new screening device for AMD shows acceptable diagnostic accuracy. The promising preliminary data of this study call for further upstream evaluations in reasonably sized clinical studies.

Abstract Image

Abstract Image

Abstract Image

识别和监测年龄相关性黄斑变性的自我监测测试的准确性:一项诊断病例对照研究。
目的:评价一种新型游标超视准直自我监测装置的诊断准确性。方法:在瑞士卢塞恩州立医院视网膜中心,共有11名湿性年龄相关性黄斑变性(AMD)患者和9名对照组,共37只眼睛被连续纳入这项前瞻性诊断病例对照研究。对所有受试者进行游标视力测试(指数测试)和光学相干断层扫描(OCT,参考测试)。视网膜专家根据诊断和指数测试结果对OCT扫描进行评估和分级。作为诊断统计量的索引测试的候选参数使用引导过程确定。剩下的10个参数在单变量分析中进一步评估。游标灵敏度测试所有四个轴上绝对距离的总标准差(SD)提供了受试者工作特征(ROC)曲线下的最高区域,因此被选中。结果:湿性AMD患者平均年龄为81.2岁(SD 4.99),平均字母数为67.4 (SD 14.1)。两组中女性的比例相似(对照组:88%,湿性AMD: 72%)。ROC曲线下面积为0.87(95%置信区间CI: 0.75 ~ 0.99),判别性良好。最佳准确度为0.64,灵敏度为75%,特异性为94%。结论:一种新的AMD筛查设备的病例对照研究显示出可接受的诊断准确性。本研究有希望的初步数据需要在合理规模的临床研究中进一步进行上游评估。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.50
自引率
0.00%
发文量
24
期刊介绍: The Open Ophthalmology Journal is an Open Access online journal, which publishes research articles, reviews/mini-reviews, letters and guest edited single topic issues in all important areas of experimental and clinical research in ophthalmology, including use of ophthalmological therapies, devices and surgical techniques. The Open Ophthalmology Journal, a peer-reviewed journal, is an important and reliable source of current information on developments in the field. The emphasis will be on publishing quality papers rapidly and making them freely available to researchers worldwide.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信