99mTc-Sestamibi/123I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?

International journal of molecular imaging Pub Date : 2017-01-01 Epub Date: 2017-10-18 DOI:10.1155/2017/2712018
Virpi Tunninen, Pekka Varjo, Tomi Kauppinen, Anu Holm, Hannu Eskola, Marko Seppänen
{"title":"<sup>99m</sup>Tc-Sestamibi/<sup>123</sup>I Subtraction SPECT/CT in Parathyroid Scintigraphy: Is Additional Pinhole Imaging Useful?","authors":"Virpi Tunninen,&nbsp;Pekka Varjo,&nbsp;Tomi Kauppinen,&nbsp;Anu Holm,&nbsp;Hannu Eskola,&nbsp;Marko Seppänen","doi":"10.1155/2017/2712018","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>This retrospective study evaluated whether the use of additional anterior <sup>99m</sup>Tc-sestamibi/<sup>123</sup>I pinhole imaging improves the outcome of <sup>99m</sup>Tc-sestamibi/<sup>123</sup>I subtraction SPECT/CT in parathyroid scintigraphy (PS).</p><p><strong>Materials and methods: </strong>PS using simultaneous dual-isotope subtraction methods and an acquisition protocol combining SPECT/CT and planar pinhole imaging was performed for 175 patients with primary or secondary hyperparathyroidism. All patients who proceeded to surgery with complete postsurgery laboratory findings were included in this study (<i>n</i> = 94). SPECT/CT images alone and combined with pinhole images were evaluated.</p><p><strong>Results: </strong>There were 111 enlarged parathyroid glands of which 104 and 108 glands were correctly visualized by SPECT/CT (seven false positives) or SPECT/CT with pinhole (three false positives), respectively. Both sensitivity and specificity were higher with combined SPECT/CT with pinhole than with SPECT/CT alone (97% versus 94% and 99% versus 98%, resp., not significant). The false-positive rate was 6% with SPECT/CT and decreased to 3% using combined SPECT/CT with pinhole.</p><p><strong>Conclusion: </strong><sup>99m</sup>Tc-sestamibi/<sup>123</sup>I subtraction SPECT/CT is a highly sensitive and specific protocol for PS. The use of additional anterior pinhole imaging increases both sensitivity and specificity of PS, although this increase is not statistically significant.</p>","PeriodicalId":89157,"journal":{"name":"International journal of molecular imaging","volume":"2017 ","pages":"2712018"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5664318/pdf/","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2017/2712018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/10/18 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

Abstract

Objectives: This retrospective study evaluated whether the use of additional anterior 99mTc-sestamibi/123I pinhole imaging improves the outcome of 99mTc-sestamibi/123I subtraction SPECT/CT in parathyroid scintigraphy (PS).

Materials and methods: PS using simultaneous dual-isotope subtraction methods and an acquisition protocol combining SPECT/CT and planar pinhole imaging was performed for 175 patients with primary or secondary hyperparathyroidism. All patients who proceeded to surgery with complete postsurgery laboratory findings were included in this study (n = 94). SPECT/CT images alone and combined with pinhole images were evaluated.

Results: There were 111 enlarged parathyroid glands of which 104 and 108 glands were correctly visualized by SPECT/CT (seven false positives) or SPECT/CT with pinhole (three false positives), respectively. Both sensitivity and specificity were higher with combined SPECT/CT with pinhole than with SPECT/CT alone (97% versus 94% and 99% versus 98%, resp., not significant). The false-positive rate was 6% with SPECT/CT and decreased to 3% using combined SPECT/CT with pinhole.

Conclusion: 99mTc-sestamibi/123I subtraction SPECT/CT is a highly sensitive and specific protocol for PS. The use of additional anterior pinhole imaging increases both sensitivity and specificity of PS, although this increase is not statistically significant.

Abstract Image

Abstract Image

Abstract Image

减影SPECT/CT在甲状旁腺造影中的应用:额外的针孔成像有用吗?
目的:本回顾性研究评估是否使用额外的前路99mTc-sestamibi/123I针孔成像改善99mTc-sestamibi/123I减影SPECT/CT甲状旁腺显像(PS)的结果。材料与方法:对175例原发性或继发性甲状旁腺功能亢进患者采用双同位素同时减影法和SPECT/CT结合平面针孔成像采集方案进行PS。所有进行手术且术后实验室检查结果完整的患者均纳入本研究(n = 94)。分别对单独SPECT/CT图像和结合针孔图像进行评价。结果:111例甲状旁腺肿大,其中SPECT/CT正确显像104例(假阳性7例),针孔显像108例(假阳性3例)。SPECT/CT联合针孔检查的敏感性和特异性均高于单独SPECT/CT检查(分别为97%对94%和99%对98%)。,不显著)。SPECT/CT的假阳性率为6%,而SPECT/CT联合针孔检查的假阳性率为3%。结论:99mTc-sestamibi/123I减影SPECT/CT是一种高度敏感和特异的PS诊断方案,使用额外的前针孔成像可提高PS的敏感性和特异度,但这种增加无统计学意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书