Techniques for epicardial mapping and ablation with a miniature robotic walker.

Robotic surgery (Auckland) Pub Date : 2017-01-01 Epub Date: 2017-03-23 DOI:10.2147/RSRR.S127047
Dwight A Meglan, Wener Lv, Richard J Cohen, Cameron N Riviere
{"title":"Techniques for epicardial mapping and ablation with a miniature robotic walker.","authors":"Dwight A Meglan, Wener Lv, Richard J Cohen, Cameron N Riviere","doi":"10.2147/RSRR.S127047","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Present treatments for ventricular tachycardia have significant drawbacks. To ameliorate these drawbacks, it may be advantageous to employ an epicardial robotic walker that performs mapping and ablation with precise control of needle insertion depth. This paper examines the feasibility of such a system.</p><p><strong>Methods: </strong>This paper describes techniques for epicardial mapping and depth-controlled ablation with the robotic walker. The mapping technique developed for the current form of the system uses a single equivalent moving dipole model combined with the navigation capability of the walker. The intervention technique provides saline-enhanced radio frequency ablation, with sensing of needle penetration depth. The mapping technique was demonstrated in an artificial heart model with a simulated arrhythmia focus, followed by preliminary testing in the porcine model in vivo. The ablation technique was demonstrated in an artificial tissue model, and then in chicken breast tissue ex vivo.</p><p><strong>Results: </strong>The walker located targets to within 2 mm using the SEMDM technique. No epicardial damage was found subsequent to the porcine trial in vivo. Needle insertion for ablation was controlled to within 2 mm of the target depth. Lesion size was repeatable, with diameter varying consistently in proportion to volume of saline injected.</p><p><strong>Conclusions: </strong>The experiments demonstrated the general feasibility of the techniques for mapping and depth-controlled ablation with the robotic walker.</p>","PeriodicalId":92137,"journal":{"name":"Robotic surgery (Auckland)","volume":"4 ","pages":"25-31"},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a1/2a/rsrr-4-025.PMC5619864.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Robotic surgery (Auckland)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/RSRR.S127047","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/3/23 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Present treatments for ventricular tachycardia have significant drawbacks. To ameliorate these drawbacks, it may be advantageous to employ an epicardial robotic walker that performs mapping and ablation with precise control of needle insertion depth. This paper examines the feasibility of such a system.

Methods: This paper describes techniques for epicardial mapping and depth-controlled ablation with the robotic walker. The mapping technique developed for the current form of the system uses a single equivalent moving dipole model combined with the navigation capability of the walker. The intervention technique provides saline-enhanced radio frequency ablation, with sensing of needle penetration depth. The mapping technique was demonstrated in an artificial heart model with a simulated arrhythmia focus, followed by preliminary testing in the porcine model in vivo. The ablation technique was demonstrated in an artificial tissue model, and then in chicken breast tissue ex vivo.

Results: The walker located targets to within 2 mm using the SEMDM technique. No epicardial damage was found subsequent to the porcine trial in vivo. Needle insertion for ablation was controlled to within 2 mm of the target depth. Lesion size was repeatable, with diameter varying consistently in proportion to volume of saline injected.

Conclusions: The experiments demonstrated the general feasibility of the techniques for mapping and depth-controlled ablation with the robotic walker.

Abstract Image

Abstract Image

Abstract Image

微型机器人助行器心外膜定位和消融技术。
背景:目前室性心动过速的治疗有明显的缺陷。为了改善这些缺陷,使用心外膜机器人行走器可能是有利的,它可以精确控制针的插入深度来进行定位和消融。本文探讨了该系统的可行性。方法:本文介绍了机器人行走心外膜标测和深度控制消融技术。针对当前形式的系统开发的映射技术使用了一个等效的移动偶极子模型,并结合了步行器的导航能力。介入技术提供了盐增强射频消融,具有针穿入深度感测。该技术在模拟心律失常病灶的人工心脏模型中得到了验证,随后在猪模型中进行了初步体内测试。消融技术首先在人工组织模型中进行了验证,然后在离体鸡胸组织中进行了验证。结果:步行者使用SEMDM技术将目标定位在2毫米以内。在猪体内试验后未发现心外膜损伤。消融针的插入控制在目标深度2 mm以内。病变的大小是可重复的,其直径与注射的生理盐水的体积成比例。结论:实验证明了机器人步行器定位和深度控制消融技术的总体可行性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书