{"title":"Evaluation of the Agreement Between 2 Point-Of-Care Glucometers and a Laboratory Automated Analyzer in North American Raptors.","authors":"Kara Hiebert, Sarah Reich, Matthew C Allender","doi":"10.1647/21-00006","DOIUrl":null,"url":null,"abstract":"<p><p>Blood glucose abnormalities are commonly observed in veterinary medicine. Point-of-care (POC) glucometers provide rapid results, are inexpensive, and require very small sample volumes to measure blood glucose concentrations. Although POC glucometers are used frequently in dogs and cats, there have been few studies evaluating POC glucometers in avian species, none of which include raptors. This study evaluated the agreement between a veterinary POC glucometer, a human POC glucometer, and a benchtop laboratory automated analyzer (auto analyzer) using both plasma and whole blood samples from 50 free-ranging raptors admitted to the University of Illinois Wildlife Medical Clinic (Urbana, IL, USA). The veterinary POC glucometer, when used with plasma and whole blood, and the human POC glucometer, when used with whole blood, were in poor agreement with the laboratory auto analyzer. The human POC glucometer, when used with plasma, was in greatest agreement with the laboratory auto analyzer, meeting the US Food and Drug Administration's accuracy guidelines for \"over-the-counter\" POC glucometers for use in humans. Based on these results, the use of the Contour Next EZ with plasma samples is the only POC recommended for use in raptors. Further research should focus on assessing the clinical utility of blood glucose measurements when treating various disease processes in raptors and the prognostic value of blood glucose measurements when assessing critically ill raptors.</p>","PeriodicalId":15102,"journal":{"name":"Journal of Avian Medicine and Surgery","volume":null,"pages":null},"PeriodicalIF":0.6000,"publicationDate":"2022-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Avian Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1647/21-00006","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Blood glucose abnormalities are commonly observed in veterinary medicine. Point-of-care (POC) glucometers provide rapid results, are inexpensive, and require very small sample volumes to measure blood glucose concentrations. Although POC glucometers are used frequently in dogs and cats, there have been few studies evaluating POC glucometers in avian species, none of which include raptors. This study evaluated the agreement between a veterinary POC glucometer, a human POC glucometer, and a benchtop laboratory automated analyzer (auto analyzer) using both plasma and whole blood samples from 50 free-ranging raptors admitted to the University of Illinois Wildlife Medical Clinic (Urbana, IL, USA). The veterinary POC glucometer, when used with plasma and whole blood, and the human POC glucometer, when used with whole blood, were in poor agreement with the laboratory auto analyzer. The human POC glucometer, when used with plasma, was in greatest agreement with the laboratory auto analyzer, meeting the US Food and Drug Administration's accuracy guidelines for "over-the-counter" POC glucometers for use in humans. Based on these results, the use of the Contour Next EZ with plasma samples is the only POC recommended for use in raptors. Further research should focus on assessing the clinical utility of blood glucose measurements when treating various disease processes in raptors and the prognostic value of blood glucose measurements when assessing critically ill raptors.
血糖异常在兽医学中很常见。即时血糖仪(POC)提供快速结果,价格低廉,并且需要非常小的样本量来测量血糖浓度。虽然POC血糖仪经常用于狗和猫,但很少有研究评估鸟类的POC血糖仪,其中没有一个包括猛禽。本研究利用伊利诺伊大学野生动物医学诊所(Urbana, IL, USA)收治的50只自由放养猛禽的血浆和全血样本,评估了兽医POC血糖仪、人类POC血糖仪和台式实验室自动分析仪(自动分析仪)之间的一致性。兽医用POC血糖仪和人用POC血糖仪在血浆和全血中使用时,与实验室自动分析仪的一致性较差。当与血浆一起使用时,人类POC血糖仪与实验室自动分析仪最一致,符合美国食品和药物管理局对用于人类的“非处方”POC血糖仪的准确性指南。基于这些结果,使用Contour Next EZ与血浆样品是唯一推荐用于猛禽的POC。进一步的研究应侧重于评估血糖测量在治疗猛禽各种疾病过程中的临床效用,以及评估危重猛禽时血糖测量的预后价值。
期刊介绍:
The Journal of Avian Medicine and Surgery is an international journal of the medicine and surgery of both captive and wild birds. Published materials include scientific articles, case reports, editorials, abstracts, new research, and book reviews.