A Kinked Epidural Needle Tip Preventing Placement of an Epidural Catheter.

Florin Costescu, Marcin Wąsowicz
{"title":"A Kinked Epidural Needle Tip Preventing Placement of an Epidural Catheter.","authors":"Florin Costescu, Marcin Wąsowicz","doi":"10.1213/XAA.0000000000000567","DOIUrl":null,"url":null,"abstract":"186 www.anesthesia-analgesia.org September 15, 2017 • Volume 9 • Number 6 To the Editor Written informed consent for the publication of this letter was obtained from the patient. A 51-year-old nonobese man with no history of spine disease presented for exploratory laparotomy. The patient was seated for epidural catheter placement and his back was prepped and draped in a sterile fashion. The T9–T10 interspace was identified by surface bony landmarks and a first attempt was performed at midline using a 17-Ga Tuohy needle (Arrow Inc, Reading, MA). After 2 needle redirections, there was persistent bony contact and the approach was abandoned. No out-of-the-ordinary pressure was applied to the needle. A second attempt was performed at the same interspace with the same needle through a left paramedian approach. Loss of resistance was obtained at 6.5-cm depth from skin. Additionally, identification of the epidural space was confirmed via pulsatile waveform on epidural waveform analysis through the needle (for educational purposes).1,2 A 19-Ga catheter (FlexTip Plus, multiport, Arrow Inc) was advanced through the needle, but it was impossible to thread it past 11.5 cm, corresponding to the tip of the needle. At that point, multiple maneuvers were attempted to pass the catheter without success, including injection of saline through the needle, 1-mm advancement of the needle, and rotation of the needle. A third attempt was performed at the same interspace with the same needle through a right paramedian approach with the same result. Close examination of the epidural needle revealed a small kink at the tip, making passage of the catheter impossible (Figure). When a new needle was used with the same approach, the catheter was passed easily and good analgesia was obtained. Other mechanical complications involving epidural needles have been described previously. Schlake et al3 described a case of separation of the hub from the needle shaft. Two cases of fractured Tuohy needle have been reported in obese parturients.4,5 Finally, Lipov et al6 described severe kinking of a Tuohy needle during epidural steroid injection in an obese patient. In the present case, it is likely that forceful bony contacts caused denting of the tip of the needle, which was not noticed until careful visual examination was performed. Another possibility, although much less likely, is that there was a preexisting manufacturing defect. Difficulties with threading an epidural catheter through the needle are not uncommon and often result in maneuvers such as advancing the needle further or rotating it, thereby increasing the risk of dural puncture. It is also sometimes interpreted as inappropriate position of the needle tip outside of the epidural space. In our opinion, anesthesiologists should be aware of the potential for a kinked needle tip and be particularly suspicious when evidence of proper epidural space identification such as convincing loss of resistance or pulsatile epidural waveform is present. We recommend careful examination of the epidural catheterization equipment before and after each insertion attempt, particularly if forceful bony contact has been applied.","PeriodicalId":6824,"journal":{"name":"A&A Case Reports ","volume":"9 6","pages":"186"},"PeriodicalIF":0.0000,"publicationDate":"2017-09-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1213/XAA.0000000000000567","citationCount":"1","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"A&A Case Reports ","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1213/XAA.0000000000000567","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

Abstract

186 www.anesthesia-analgesia.org September 15, 2017 • Volume 9 • Number 6 To the Editor Written informed consent for the publication of this letter was obtained from the patient. A 51-year-old nonobese man with no history of spine disease presented for exploratory laparotomy. The patient was seated for epidural catheter placement and his back was prepped and draped in a sterile fashion. The T9–T10 interspace was identified by surface bony landmarks and a first attempt was performed at midline using a 17-Ga Tuohy needle (Arrow Inc, Reading, MA). After 2 needle redirections, there was persistent bony contact and the approach was abandoned. No out-of-the-ordinary pressure was applied to the needle. A second attempt was performed at the same interspace with the same needle through a left paramedian approach. Loss of resistance was obtained at 6.5-cm depth from skin. Additionally, identification of the epidural space was confirmed via pulsatile waveform on epidural waveform analysis through the needle (for educational purposes).1,2 A 19-Ga catheter (FlexTip Plus, multiport, Arrow Inc) was advanced through the needle, but it was impossible to thread it past 11.5 cm, corresponding to the tip of the needle. At that point, multiple maneuvers were attempted to pass the catheter without success, including injection of saline through the needle, 1-mm advancement of the needle, and rotation of the needle. A third attempt was performed at the same interspace with the same needle through a right paramedian approach with the same result. Close examination of the epidural needle revealed a small kink at the tip, making passage of the catheter impossible (Figure). When a new needle was used with the same approach, the catheter was passed easily and good analgesia was obtained. Other mechanical complications involving epidural needles have been described previously. Schlake et al3 described a case of separation of the hub from the needle shaft. Two cases of fractured Tuohy needle have been reported in obese parturients.4,5 Finally, Lipov et al6 described severe kinking of a Tuohy needle during epidural steroid injection in an obese patient. In the present case, it is likely that forceful bony contacts caused denting of the tip of the needle, which was not noticed until careful visual examination was performed. Another possibility, although much less likely, is that there was a preexisting manufacturing defect. Difficulties with threading an epidural catheter through the needle are not uncommon and often result in maneuvers such as advancing the needle further or rotating it, thereby increasing the risk of dural puncture. It is also sometimes interpreted as inappropriate position of the needle tip outside of the epidural space. In our opinion, anesthesiologists should be aware of the potential for a kinked needle tip and be particularly suspicious when evidence of proper epidural space identification such as convincing loss of resistance or pulsatile epidural waveform is present. We recommend careful examination of the epidural catheterization equipment before and after each insertion attempt, particularly if forceful bony contact has been applied.
弯曲的硬膜外针尖防止放置硬膜外导管。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信