System Integration and Preliminary In-Vivo Experiments of a Robot for Ultrasound Guidance and Monitoring during Radiotherapy.

H Tutkun Şen, Muyinatu A Lediju Bell, Yin Zhang, Kai Ding, John Wong, Iulian Iordachita, Peter Kazanzides
{"title":"System Integration and Preliminary In-Vivo Experiments of a Robot for Ultrasound Guidance and Monitoring during Radiotherapy.","authors":"H Tutkun Şen,&nbsp;Muyinatu A Lediju Bell,&nbsp;Yin Zhang,&nbsp;Kai Ding,&nbsp;John Wong,&nbsp;Iulian Iordachita,&nbsp;Peter Kazanzides","doi":"10.1109/ICAR.2015.7251433","DOIUrl":null,"url":null,"abstract":"<p><p>We are developing a cooperatively-controlled robot system in which a clinician and robot share control of a 3D ultrasound (US) probe. The goals of the system are to provide guidance for patient setup and real-time target monitoring during fractionated radiotherapy. Currently, there is limited use of realtime US image feedback during radiotherapy for lower abdominal organs and it has not yet been clinically applied for upper abdominal organs. One challenge is that placing an US probe on the patient produces tissue deformation around the target organ, leading to displacement of the target. Our solution is to perform treatment planning on the deformed organ and then to reproduce this deformation during radiotherapy. We therefore introduce a robot system to hold the US probe on the patient. In order to create a consistent deformation, the system records the robot position, contact force, and reference US image during simulation and then introduces virtual constraints (soft virtual fixtures) to guide the clinician to correctly place the probe during the fractionated treatments. Because the robot is under-actuated (5 motorized and 6 passive degrees-of-freedom), the guidance also involves a graphical user interface (adjustment GUI) to achieve the desired probe orientation. This paper presents the integrated system, a proposed clinical workflow, the results of an initial in-vivo canine study with a 3-DOF robot, and the results of phantom experiments with an improved 5-DOF robotic system. The results suggest that the guidance may enable the clinician to more consistently and accurately place the US probe.</p>","PeriodicalId":91596,"journal":{"name":"Proceedings of ... International Conference on Advanced Robotics. International Conference on Advanced Robotics","volume":"2015 ","pages":"53-59"},"PeriodicalIF":0.0000,"publicationDate":"2015-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1109/ICAR.2015.7251433","citationCount":"18","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Proceedings of ... International Conference on Advanced Robotics. International Conference on Advanced Robotics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/ICAR.2015.7251433","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

Abstract

We are developing a cooperatively-controlled robot system in which a clinician and robot share control of a 3D ultrasound (US) probe. The goals of the system are to provide guidance for patient setup and real-time target monitoring during fractionated radiotherapy. Currently, there is limited use of realtime US image feedback during radiotherapy for lower abdominal organs and it has not yet been clinically applied for upper abdominal organs. One challenge is that placing an US probe on the patient produces tissue deformation around the target organ, leading to displacement of the target. Our solution is to perform treatment planning on the deformed organ and then to reproduce this deformation during radiotherapy. We therefore introduce a robot system to hold the US probe on the patient. In order to create a consistent deformation, the system records the robot position, contact force, and reference US image during simulation and then introduces virtual constraints (soft virtual fixtures) to guide the clinician to correctly place the probe during the fractionated treatments. Because the robot is under-actuated (5 motorized and 6 passive degrees-of-freedom), the guidance also involves a graphical user interface (adjustment GUI) to achieve the desired probe orientation. This paper presents the integrated system, a proposed clinical workflow, the results of an initial in-vivo canine study with a 3-DOF robot, and the results of phantom experiments with an improved 5-DOF robotic system. The results suggest that the guidance may enable the clinician to more consistently and accurately place the US probe.

放疗超声引导监测机器人的系统集成与体内初步实验。
我们正在开发一种协作控制的机器人系统,在该系统中,临床医生和机器人共同控制3D超声(US)探头。该系统的目标是在分步放疗过程中为患者设置和实时靶标监测提供指导。目前,实时US图像反馈在下腹部器官的放疗中使用有限,尚未在临床上应用于上腹部器官。其中一个挑战是,在病人身上放置一个美国探针会使目标器官周围的组织变形,导致目标器官移位。我们的解决方案是对变形的器官进行治疗计划,然后在放疗期间再现这种变形。因此,我们引入了一个机器人系统来将美国探针放在病人身上。为了产生一致的变形,系统在模拟过程中记录机器人位置、接触力和参考US图像,然后引入虚拟约束(软虚拟夹具)来指导临床医生在分步治疗过程中正确放置探头。由于机器人是欠驱动的(5个机动自由度和6个被动自由度),因此制导还涉及图形用户界面(调整GUI)以实现所需的探针方向。本文介绍了该集成系统、一个拟议的临床工作流程、一个3自由度机器人在犬体内的初步研究结果,以及一个改进的5自由度机器人系统的幻影实验结果。结果表明,该指南可以使临床医生更加一致和准确地放置超声探头。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书