A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.
{"title":"A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.","authors":"Meucci Valentina, Guidi Grazia, Melanie Pierre, Breghi Gloria, Lippi Ilaria","doi":"10.1155/2013/569121","DOIUrl":null,"url":null,"abstract":"<p><p>Glomerular filtration rate (GFR) is still a highly underutilized tool in cats because available methods are not easy to be performed in clinical practice. Iohexol (IOX) has been shown to be a useful and reliable marker of GFR both in animals and in humans. The aim of the present study was to develop a rapid and reliable method for measuring IOX in feline plasma and to evaluate the accuracy of limited sampling models to establish a low-cost and clinically suitable GFR test. IOX concentrations were determined by using a new HPLC-UV method. GFR was assessed as plasma clearance of IOX, which was calculated by dividing dose administered by area under the curve of plasmatic concentration versus time (AUC), and indexed to body weight (BW). Correlation and agreement analysis between the GFR values obtained by a seven-point clearance method and the GFR values determined by the application of simplified sample combinations indicated that the 3-blood sample clearance model (5, 30, and 60 min) was the best simplified method because it provided an accurate GFR value in only one hour. The reported method is a simple and accurate way of GFR determination, which may be easily used in a clinical setting. </p>","PeriodicalId":91135,"journal":{"name":"Journal of veterinary medicine","volume":"2013 ","pages":"569121"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4590869/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/569121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/11/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Glomerular filtration rate (GFR) is still a highly underutilized tool in cats because available methods are not easy to be performed in clinical practice. Iohexol (IOX) has been shown to be a useful and reliable marker of GFR both in animals and in humans. The aim of the present study was to develop a rapid and reliable method for measuring IOX in feline plasma and to evaluate the accuracy of limited sampling models to establish a low-cost and clinically suitable GFR test. IOX concentrations were determined by using a new HPLC-UV method. GFR was assessed as plasma clearance of IOX, which was calculated by dividing dose administered by area under the curve of plasmatic concentration versus time (AUC), and indexed to body weight (BW). Correlation and agreement analysis between the GFR values obtained by a seven-point clearance method and the GFR values determined by the application of simplified sample combinations indicated that the 3-blood sample clearance model (5, 30, and 60 min) was the best simplified method because it provided an accurate GFR value in only one hour. The reported method is a simple and accurate way of GFR determination, which may be easily used in a clinical setting.
在猫科动物中,肾小球滤过率(GFR)仍然是一种利用率极低的工具,因为现有的方法在临床实践中不易操作。在动物和人类中,异己醇(IOX)已被证明是肾小球滤过率的一种有用而可靠的标记物。本研究旨在开发一种快速、可靠的方法来测量猫血浆中的 IOX,并评估有限采样模型的准确性,以建立一种低成本、适合临床的 GFR 检测方法。IOX 浓度是通过一种新型 HPLC-UV 方法测定的。通过将给药剂量除以血浆浓度随时间变化的曲线下面积(AUC)来计算IOX的血浆清除率,并与体重(BW)挂钩,从而评估GFR。七点清除率法得出的 GFR 值与应用简化样本组合确定的 GFR 值之间的相关性和一致性分析表明,三血样本清除率模型(5、30 和 60 分钟)是最好的简化方法,因为它只需一小时就能提供准确的 GFR 值。所报告的方法是一种简单而准确的 GFR 测定方法,可方便地应用于临床。