A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.

Journal of veterinary medicine Pub Date : 2013-01-01 Epub Date: 2013-11-12 DOI:10.1155/2013/569121
Meucci Valentina, Guidi Grazia, Melanie Pierre, Breghi Gloria, Lippi Ilaria
{"title":"A Limited Sampling, Simple, and Useful Method for Determination of Glomerular Filtration Rate in Cats by Using a New Accurate HPLC Method to Measure Iohexol Plasmatic Concentrations.","authors":"Meucci Valentina, Guidi Grazia, Melanie Pierre, Breghi Gloria, Lippi Ilaria","doi":"10.1155/2013/569121","DOIUrl":null,"url":null,"abstract":"<p><p>Glomerular filtration rate (GFR) is still a highly underutilized tool in cats because available methods are not easy to be performed in clinical practice. Iohexol (IOX) has been shown to be a useful and reliable marker of GFR both in animals and in humans. The aim of the present study was to develop a rapid and reliable method for measuring IOX in feline plasma and to evaluate the accuracy of limited sampling models to establish a low-cost and clinically suitable GFR test. IOX concentrations were determined by using a new HPLC-UV method. GFR was assessed as plasma clearance of IOX, which was calculated by dividing dose administered by area under the curve of plasmatic concentration versus time (AUC), and indexed to body weight (BW). Correlation and agreement analysis between the GFR values obtained by a seven-point clearance method and the GFR values determined by the application of simplified sample combinations indicated that the 3-blood sample clearance model (5, 30, and 60 min) was the best simplified method because it provided an accurate GFR value in only one hour. The reported method is a simple and accurate way of GFR determination, which may be easily used in a clinical setting. </p>","PeriodicalId":91135,"journal":{"name":"Journal of veterinary medicine","volume":"2013 ","pages":"569121"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4590869/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of veterinary medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/569121","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/11/12 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Glomerular filtration rate (GFR) is still a highly underutilized tool in cats because available methods are not easy to be performed in clinical practice. Iohexol (IOX) has been shown to be a useful and reliable marker of GFR both in animals and in humans. The aim of the present study was to develop a rapid and reliable method for measuring IOX in feline plasma and to evaluate the accuracy of limited sampling models to establish a low-cost and clinically suitable GFR test. IOX concentrations were determined by using a new HPLC-UV method. GFR was assessed as plasma clearance of IOX, which was calculated by dividing dose administered by area under the curve of plasmatic concentration versus time (AUC), and indexed to body weight (BW). Correlation and agreement analysis between the GFR values obtained by a seven-point clearance method and the GFR values determined by the application of simplified sample combinations indicated that the 3-blood sample clearance model (5, 30, and 60 min) was the best simplified method because it provided an accurate GFR value in only one hour. The reported method is a simple and accurate way of GFR determination, which may be easily used in a clinical setting.

Abstract Image

Abstract Image

Abstract Image

使用新型精确高效液相色谱法测量 Iohexol 血浆浓度,是一种取样有限、简单实用的猫肾小球滤过率测定方法。
在猫科动物中,肾小球滤过率(GFR)仍然是一种利用率极低的工具,因为现有的方法在临床实践中不易操作。在动物和人类中,异己醇(IOX)已被证明是肾小球滤过率的一种有用而可靠的标记物。本研究旨在开发一种快速、可靠的方法来测量猫血浆中的 IOX,并评估有限采样模型的准确性,以建立一种低成本、适合临床的 GFR 检测方法。IOX 浓度是通过一种新型 HPLC-UV 方法测定的。通过将给药剂量除以血浆浓度随时间变化的曲线下面积(AUC)来计算IOX的血浆清除率,并与体重(BW)挂钩,从而评估GFR。七点清除率法得出的 GFR 值与应用简化样本组合确定的 GFR 值之间的相关性和一致性分析表明,三血样本清除率模型(5、30 和 60 分钟)是最好的简化方法,因为它只需一小时就能提供准确的 GFR 值。所报告的方法是一种简单而准确的 GFR 测定方法,可方便地应用于临床。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信