Risk factors for external root resorption of maxillary second molars associated with third molars.

IF 1.7 Q3 DENTISTRY, ORAL SURGERY & MEDICINE
Imaging Science in Dentistry Pub Date : 2022-09-01 Epub Date: 2022-05-13 DOI:10.5624/isd.20220401
Jinwoo Choi
{"title":"Risk factors for external root resorption of maxillary second molars associated with third molars.","authors":"Jinwoo Choi","doi":"10.5624/isd.20220401","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This study aimed to evaluate the diagnostic performance of panoramic images compared to cone-beam computed tomography (CBCT) imaging for maxillary third molar (M3)-associated external root resorption (ERR), and to identify the risk factors of ERR on panoramic images.</p><p><strong>Materials and methods: </strong>The study population was composed of all patients who underwent panoramic imaging at Dankook University Dental Hospital from May to October 2019. In total, 397 cases of maxillary M3s in 247 patients (147 men and 100 women) were included. The diagnostic accuracy of ERR in panoramic images compared to CBCT images was evaluated using the chi-square test. To identify risk factors for ERR, dental records and panoramic findings were evaluated by logistic regression analysis.</p><p><strong>Results: </strong>The diagnostic accuracy of ERR on panoramic images was 0.79 compared to CBCT images (<i>P</i><0.05). Superimposition of M3s onto second molars (M2) was associated with an approximately 33 times higher risk of ERR than separated M3s (<i>P</i><0.05). Impacted M3s showed a 5 times higher risk of ERR than erupted M3s (<i>P</i><0.05).</p><p><strong>Conclusion: </strong>ERR related to M3s is a common clinical condition, and superimposition of M3 onto M2 on panoramic images was the most important risk factor for ERR. It seemed that CBCT examinations for maxillary M3s might be indicated for ERR diagnosis especially if panoramic radiographs show superimposition of M3 onto M2. Impaction itself was also a risk factor, and it should be carefully examined.</p>","PeriodicalId":51714,"journal":{"name":"Imaging Science in Dentistry","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/70/3a/isd-52-289.PMC9530300.pdf","citationCount":"3","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Imaging Science in Dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5624/isd.20220401","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/5/13 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 3

Abstract

Purpose: This study aimed to evaluate the diagnostic performance of panoramic images compared to cone-beam computed tomography (CBCT) imaging for maxillary third molar (M3)-associated external root resorption (ERR), and to identify the risk factors of ERR on panoramic images.

Materials and methods: The study population was composed of all patients who underwent panoramic imaging at Dankook University Dental Hospital from May to October 2019. In total, 397 cases of maxillary M3s in 247 patients (147 men and 100 women) were included. The diagnostic accuracy of ERR in panoramic images compared to CBCT images was evaluated using the chi-square test. To identify risk factors for ERR, dental records and panoramic findings were evaluated by logistic regression analysis.

Results: The diagnostic accuracy of ERR on panoramic images was 0.79 compared to CBCT images (P<0.05). Superimposition of M3s onto second molars (M2) was associated with an approximately 33 times higher risk of ERR than separated M3s (P<0.05). Impacted M3s showed a 5 times higher risk of ERR than erupted M3s (P<0.05).

Conclusion: ERR related to M3s is a common clinical condition, and superimposition of M3 onto M2 on panoramic images was the most important risk factor for ERR. It seemed that CBCT examinations for maxillary M3s might be indicated for ERR diagnosis especially if panoramic radiographs show superimposition of M3 onto M2. Impaction itself was also a risk factor, and it should be carefully examined.

Abstract Image

Abstract Image

Abstract Image

上颌第二磨牙合并第三磨牙外根吸收的危险因素。
目的:本研究旨在评价全景图像与锥束计算机断层扫描(CBCT)对上颌第三磨牙(M3)相关外根吸收(ERR)的诊断效果,并探讨全景图像上ERR的危险因素。材料和方法:研究人群由2019年5月至10月在檀国大学牙科医院接受全景成像的所有患者组成。共纳入247例患者(男性147例,女性100例)397例上颌M3s。采用卡方检验评估全景图像与CBCT图像ERR的诊断准确性。为了确定ERR的危险因素,通过logistic回归分析评估牙科记录和全景检查结果。结果:全景影像上ERR与CBCT影像的诊断准确率为0.79 (ppp)。结论:与M3相关的ERR是一种常见的临床症状,全景影像上M3与M2叠加是ERR最重要的危险因素。CBCT检查上颌M3s可作为ERR的诊断依据,尤其是当全景x线片显示M3与M2重叠时。撞击本身也是一个危险因素,应该仔细检查。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Imaging Science in Dentistry
Imaging Science in Dentistry DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
2.90
自引率
11.10%
发文量
42
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信