Bias Assessment of General Chemistry Analytes using Commutable Samples.

Q1 Biochemistry, Genetics and Molecular Biology
Clinical Biochemist Reviews Pub Date : 2014-11-01
Gus Koerbin, Jillian R Tate, Julie Ryan, Graham Rd Jones, Ken A Sikaris, David Kanowski, Maxine Reed, Janice Gill, George Koumantakis, Tina Yen, Andrew St John, Peter E Hickman, Aaron Simpson, Peter Graham
{"title":"Bias Assessment of General Chemistry Analytes using Commutable Samples.","authors":"Gus Koerbin,&nbsp;Jillian R Tate,&nbsp;Julie Ryan,&nbsp;Graham Rd Jones,&nbsp;Ken A Sikaris,&nbsp;David Kanowski,&nbsp;Maxine Reed,&nbsp;Janice Gill,&nbsp;George Koumantakis,&nbsp;Tina Yen,&nbsp;Andrew St John,&nbsp;Peter E Hickman,&nbsp;Aaron Simpson,&nbsp;Peter Graham","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals. </p>","PeriodicalId":34924,"journal":{"name":"Clinical Biochemist Reviews","volume":"35 4","pages":"203-11"},"PeriodicalIF":0.0000,"publicationDate":"2014-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC4310060/pdf/cbr-35-203.pdf","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical Biochemist Reviews","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Biochemistry, Genetics and Molecular Biology","Score":null,"Total":0}
引用次数: 0

Abstract

Harmonisation of reference intervals for routine general chemistry analytes has been a goal for many years. Analytical bias may prevent this harmonisation. To determine if analytical bias is present when comparing methods, the use of commutable samples, or samples that have the same properties as the clinical samples routinely analysed, should be used as reference samples to eliminate the possibility of matrix effect. The use of commutable samples has improved the identification of unacceptable analytical performance in the Netherlands and Spain. The International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) has undertaken a pilot study using commutable samples in an attempt to determine not only country specific reference intervals but to make them comparable between countries. Australia and New Zealand, through the Australasian Association of Clinical Biochemists (AACB), have also undertaken an assessment of analytical bias using commutable samples and determined that of the 27 general chemistry analytes studied, 19 showed sufficiently small between method biases as to not prevent harmonisation of reference intervals. Application of evidence based approaches including the determination of analytical bias using commutable material is necessary when seeking to harmonise reference intervals.

Abstract Image

Abstract Image

Abstract Image

使用可交换样品的普通化学分析物的偏倚评估。
统一常规普通化学分析的参考区间是多年来的目标。分析上的偏见可能会阻碍这种协调。为了确定在比较方法时是否存在分析偏差,应使用可交换样品或与常规分析的临床样品具有相同性质的样品作为参考样品,以消除基质效应的可能性。在荷兰和西班牙,可交换样品的使用改善了对不可接受分析性能的识别。国际临床化学和实验室医学联合会进行了一项使用可交换样品的试验性研究,以期不仅确定具体国家的参考间隔,而且使它们在各国之间具有可比性。澳大利亚和新西兰,通过澳大利亚临床生物化学家协会(AACB),也使用可交换样品对分析偏差进行了评估,并确定在所研究的27种普通化学分析中,19种方法之间的偏差足够小,不会妨碍参考区间的协调。在寻求协调参考区间时,应用基于证据的方法,包括使用可交换材料确定分析偏差是必要的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Clinical Biochemist Reviews
Clinical Biochemist Reviews Biochemistry, Genetics and Molecular Biology-Clinical Biochemistry
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信