Correlation between Saliva and Plasma Levels of Endothelin Isoforms ET-1, ET-2, and ET-3.

International Journal of Peptides Pub Date : 2015-01-01 Epub Date: 2015-04-20 DOI:10.1155/2015/828759
Roma Gurusankar, Prem Kumarathasan, Anusha Saravanamuthu, Errol M Thomson, Renaud Vincent
{"title":"Correlation between Saliva and Plasma Levels of Endothelin Isoforms ET-1, ET-2, and ET-3.","authors":"Roma Gurusankar,&nbsp;Prem Kumarathasan,&nbsp;Anusha Saravanamuthu,&nbsp;Errol M Thomson,&nbsp;Renaud Vincent","doi":"10.1155/2015/828759","DOIUrl":null,"url":null,"abstract":"<p><p>Although saliva endothelins are emerging as valuable noninvasive cardiovascular biomarkers, reports on the relationship between isoforms in saliva and plasma remain scarce. We measured endothelins in concurrent saliva and plasma samples (n = 30 males; age 18-63) by HPLC-fluorescence. Results revealed statistically significant positive correlations among all isoforms between saliva and plasma: big endothelin-1 (BET-1, 0.55 ± 0.27 versus 3.35 ± 1.28 pmol/mL; r = 0.38, p = 0.041), endothelin-1 (ET-1, 0.52 ± 0.21 versus 3.45 ± 1.28 pmol/mL; r = 0.53, p = 0.003), endothelin-2 (ET-2, 0.21 ± 0.07 versus 1.63 ± 0.66 pmol/mL; r = 0.51, p = 0.004), and endothelin-3 (ET-3, 0.39 ± 0.19 versus 2.32 ± 1.44 pmol/mL; r = 0.75, p < 0.001). Correlations of BET-1, ET-1, and ET-3 within each compartment were positive in both plasma (p < 0.05) and saliva (p ≤ 0.1), whereas ET-2 was not significantly correlated with other isoforms in either plasma or saliva. For all isoforms, concentrations varied on average fivefold between individuals (90th/10th percentiles); individuals with high plasma endothelin levels generally had high saliva endothelin levels. Our results reveal that salivary ET isoform profiles portray the plasmatic profiles and support the view of coordinated regulation of ET-1 and ET-3, but distinct regulatory pathways for ET-2. </p>","PeriodicalId":14239,"journal":{"name":"International Journal of Peptides","volume":"2015 ","pages":"828759"},"PeriodicalIF":0.0000,"publicationDate":"2015-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2015/828759","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Peptides","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2015/828759","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/4/20 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Although saliva endothelins are emerging as valuable noninvasive cardiovascular biomarkers, reports on the relationship between isoforms in saliva and plasma remain scarce. We measured endothelins in concurrent saliva and plasma samples (n = 30 males; age 18-63) by HPLC-fluorescence. Results revealed statistically significant positive correlations among all isoforms between saliva and plasma: big endothelin-1 (BET-1, 0.55 ± 0.27 versus 3.35 ± 1.28 pmol/mL; r = 0.38, p = 0.041), endothelin-1 (ET-1, 0.52 ± 0.21 versus 3.45 ± 1.28 pmol/mL; r = 0.53, p = 0.003), endothelin-2 (ET-2, 0.21 ± 0.07 versus 1.63 ± 0.66 pmol/mL; r = 0.51, p = 0.004), and endothelin-3 (ET-3, 0.39 ± 0.19 versus 2.32 ± 1.44 pmol/mL; r = 0.75, p < 0.001). Correlations of BET-1, ET-1, and ET-3 within each compartment were positive in both plasma (p < 0.05) and saliva (p ≤ 0.1), whereas ET-2 was not significantly correlated with other isoforms in either plasma or saliva. For all isoforms, concentrations varied on average fivefold between individuals (90th/10th percentiles); individuals with high plasma endothelin levels generally had high saliva endothelin levels. Our results reveal that salivary ET isoform profiles portray the plasmatic profiles and support the view of coordinated regulation of ET-1 and ET-3, but distinct regulatory pathways for ET-2.

Abstract Image

Abstract Image

Abstract Image

唾液和血浆内皮素异构体ET-1、ET-2和ET-3水平的相关性
尽管唾液内皮素正在成为有价值的无创心血管生物标志物,但关于唾液和血浆中同种异构体之间关系的报道仍然很少。我们同时测量了唾液和血浆样本中的内皮素(n = 30名男性;年龄18-63岁)。结果显示,唾液和血浆各亚型之间存在显著正相关:大内皮素-1 (BET-1)为0.55±0.27比3.35±1.28 pmol/mL;r = 0.38, p = 0.041),内皮素-1 (ET-1, 0.52±0.21比3.45±1.28 pmol/mL;r = 0.53, p = 0.003),内皮素-2 (ET-2, 0.21±0.07 vs 1.63±0.66 pmol/mL;r = 0.51, p = 0.004),内皮素-3 (ET-3, 0.39±0.19 vs 2.32±1.44 pmol/mL;R = 0.75, p < 0.001)。血浆和唾液中ET-1、ET-1和ET-3的相关性均为正(p < 0.05),而ET-2与血浆和唾液中其他亚型的相关性均不显著。对于所有同种异构体,个体之间的浓度平均相差5倍(90 /10百分位数);血浆内皮素水平高的个体通常唾液内皮素水平也高。我们的研究结果表明,唾液ET异构体谱描绘了血浆谱,并支持ET-1和ET-3协调调节的观点,但ET-2的调节途径不同。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信