J P Duarte, Manuel J Coelho-E-Silva, V Severino, D Martinho, L Luz, J R Pereira, R Baptista, J Valente-Dos-Santos, A M Machado-Rodrigues, V Vaz, A Cupido-Dos-Santos, J Martín-Hernández, S P Cumming, R M Malina
{"title":"Reproducibility of peak power output during a 10-s cycling maximal effort using different sampling rates.","authors":"J P Duarte, Manuel J Coelho-E-Silva, V Severino, D Martinho, L Luz, J R Pereira, R Baptista, J Valente-Dos-Santos, A M Machado-Rodrigues, V Vaz, A Cupido-Dos-Santos, J Martín-Hernández, S P Cumming, R M Malina","doi":"10.1556/APhysiol.101.2014.009","DOIUrl":null,"url":null,"abstract":"<p><p>The study was aimed to investigate the reproducibility of performance parameters obtained from 10-s maximal cycling effort against different braking forces in young adult athletes. The sample (n = 48) included male athletes aged 18.9-29.9 years (175.5 ± 6.9 cm, 76.2 ± 10.1 kg). The exercise protocol was performed in a cycle-ergometer against a random braking force (4% to 11% of body mass). Intra-individual variation was examined from repeated tests within one week. Descriptive statistics were computed and differences between sessions were tested using paired t-test. The coefficient of correlation between repeated measures, technical error of measurement (TEM), coefficient of variation and ICC were calculated. Agreement between trials was examined using the Bland-Altman procedure. Mean values of peak power were relatively stable when obtained from sampling rates of 50 Hz and ranged between 1068 watt and 1082 watt (t(47) = 1.149, p = 0.256, ES-r = 0.165) or while corresponding to a sampling rate of 1 Hz (t(47) = 0.742, p = 0.462, ES-r = 0.107). Correlations between repeated measures were high (+0.907, 95% CI: +0.839 to +0.947) and TEM about 59.3 watt (%CV = 5.52%; ICC = 0.951, 95% CI: 0.912 to 0.972). The present study suggests that reproducibility of peak power in male adult athletes tended to be acceptable and within individual error appeared unrelated to braking force. </p>","PeriodicalId":7167,"journal":{"name":"Acta physiologica Hungarica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2014-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1556/APhysiol.101.2014.009","citationCount":"2","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta physiologica Hungarica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1556/APhysiol.101.2014.009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2
Abstract
The study was aimed to investigate the reproducibility of performance parameters obtained from 10-s maximal cycling effort against different braking forces in young adult athletes. The sample (n = 48) included male athletes aged 18.9-29.9 years (175.5 ± 6.9 cm, 76.2 ± 10.1 kg). The exercise protocol was performed in a cycle-ergometer against a random braking force (4% to 11% of body mass). Intra-individual variation was examined from repeated tests within one week. Descriptive statistics were computed and differences between sessions were tested using paired t-test. The coefficient of correlation between repeated measures, technical error of measurement (TEM), coefficient of variation and ICC were calculated. Agreement between trials was examined using the Bland-Altman procedure. Mean values of peak power were relatively stable when obtained from sampling rates of 50 Hz and ranged between 1068 watt and 1082 watt (t(47) = 1.149, p = 0.256, ES-r = 0.165) or while corresponding to a sampling rate of 1 Hz (t(47) = 0.742, p = 0.462, ES-r = 0.107). Correlations between repeated measures were high (+0.907, 95% CI: +0.839 to +0.947) and TEM about 59.3 watt (%CV = 5.52%; ICC = 0.951, 95% CI: 0.912 to 0.972). The present study suggests that reproducibility of peak power in male adult athletes tended to be acceptable and within individual error appeared unrelated to braking force.