Lyophilized Kit for the Preparation of the PET Perfusion Agent [(68)Ga]-MAA.

International journal of molecular imaging Pub Date : 2014-01-01 Epub Date: 2014-03-31 DOI:10.1155/2014/269365
Alejandro Amor-Coarasa, Andrew Milera, Denny Carvajal, Seza Gulec, Anthony J McGoron
{"title":"Lyophilized Kit for the Preparation of the PET Perfusion Agent [(68)Ga]-MAA.","authors":"Alejandro Amor-Coarasa,&nbsp;Andrew Milera,&nbsp;Denny Carvajal,&nbsp;Seza Gulec,&nbsp;Anthony J McGoron","doi":"10.1155/2014/269365","DOIUrl":null,"url":null,"abstract":"<p><p>Rapid developments in the field of medical imaging have opened new avenues for the use of positron emitting labeled microparticles. The radioisotope used in our research was (68)Ga, which is easy to obtain from a generator and has good nuclear properties for PET imaging. Methods. Commercially available macroaggregated albumin (MAA) microparticles were suspended in sterile saline, centrifuged to remove the free albumin and stannous chloride, relyophilized, and stored for later labeling with (68)Ga. Labeling was performed at different temperatures and times. (68)Ga purification settings were also tested and optimized. Labeling yield and purity of relyophilized MAA microparticles were compared with those that were not relyophilized. Results. MAA particles kept their original size distribution after relyophilization. Labeling yield was 98% at 75°C when a (68)Ga purification system was used, compared to 80% with unpurified (68)Ga. Radiochemical purity was over 97% up to 4 hours after the labeling. The relyophilized MAA and labeling method eliminate the need for centrifugation purification of the final product and simplify the labeling process. Animal experiments demonstrated the high in vivo stability of the obtained PET agent with more than 95% of the activity remaining in the lungs after 4 hours. </p>","PeriodicalId":89157,"journal":{"name":"International journal of molecular imaging","volume":"2014 ","pages":"269365"},"PeriodicalIF":0.0000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2014/269365","citationCount":"19","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2014/269365","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/3/31 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

Abstract

Rapid developments in the field of medical imaging have opened new avenues for the use of positron emitting labeled microparticles. The radioisotope used in our research was (68)Ga, which is easy to obtain from a generator and has good nuclear properties for PET imaging. Methods. Commercially available macroaggregated albumin (MAA) microparticles were suspended in sterile saline, centrifuged to remove the free albumin and stannous chloride, relyophilized, and stored for later labeling with (68)Ga. Labeling was performed at different temperatures and times. (68)Ga purification settings were also tested and optimized. Labeling yield and purity of relyophilized MAA microparticles were compared with those that were not relyophilized. Results. MAA particles kept their original size distribution after relyophilization. Labeling yield was 98% at 75°C when a (68)Ga purification system was used, compared to 80% with unpurified (68)Ga. Radiochemical purity was over 97% up to 4 hours after the labeling. The relyophilized MAA and labeling method eliminate the need for centrifugation purification of the final product and simplify the labeling process. Animal experiments demonstrated the high in vivo stability of the obtained PET agent with more than 95% of the activity remaining in the lungs after 4 hours.

Abstract Image

Abstract Image

Abstract Image

PET灌注剂[(68)Ga]-MAA制备冻干试剂盒。
医学成像领域的快速发展为使用正电子发射标记微粒开辟了新的途径。我们研究中使用的放射性同位素是(68)Ga,它很容易从发生器中获得,并且具有良好的PET成像核性质。方法。将市售的大聚集白蛋白(MAA)微粒悬浮在无菌生理盐水中,离心去除游离白蛋白和氯化亚锡,再干燥,保存以供稍后用(68)Ga标记。在不同温度和时间下进行标记。(68)对Ga净化设置也进行了测试和优化。将再干燥MAA微粒与未再干燥MAA微粒的标记率和纯度进行比较。结果。再干燥后MAA颗粒保持原有的尺寸分布。当使用(68)Ga纯化系统时,标记收率在75°C下为98%,而未纯化的(68)Ga则为80%。放射化学纯度在标记后4小时仍超过97%。再干燥MAA和标记方法消除了对最终产品的离心纯化的需要,简化了标记过程。动物实验表明,PET制剂具有较高的体内稳定性,4小时后仍有95%以上的活性留在肺部。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书