DWI of Prostate Cancer: Optimal b-Value in Clinical Practice.

IF 2.3 Q3 ONCOLOGY
Prostate Cancer Pub Date : 2014-01-01 Epub Date: 2014-02-18 DOI:10.1155/2014/868269
Guglielmo Manenti, Marco Nezzo, Fabrizio Chegai, Erald Vasili, Elena Bonanno, Giovanni Simonetti
{"title":"DWI of Prostate Cancer: Optimal b-Value in Clinical Practice.","authors":"Guglielmo Manenti,&nbsp;Marco Nezzo,&nbsp;Fabrizio Chegai,&nbsp;Erald Vasili,&nbsp;Elena Bonanno,&nbsp;Giovanni Simonetti","doi":"10.1155/2014/868269","DOIUrl":null,"url":null,"abstract":"<p><p>Aim. To compare the diagnostic performance of diffusion weighted imaging (DWI) using b-values of 1000 s/mm(2) and 2000 s/mm(2) at 3 Tesla (T) for the evaluation of clinically significant prostate cancer. Matherials and Methods. Seventy-eight prostate cancer patients underwent a 3T MRI scan followed by radical prostatectomy. DWI was performed using b-values of 0, 1000, and 2000 s/mm(2) and qualitatively analysed by two radiologists. ADC maps were obtained at b-values of 1000 and 2000 s/mm(2) and quantitatively analyzed in consensus. Results. For diagnosis of 78 prostate cancers the accuracy of DWI for the young reader was significantly greater at b = 2000 s/mm(2) for the peripheral zone (PZ) but not for the transitional zone (TZ). For the experienced reader, DWI did not show significant differences in accuracy between b-values of 1000 and 2000 s/mm(2). The quantitative analysis in the PZ and TZ was substantially superimposable between the two b-values, albeit with a higher accuracy with a b-value of 2000 s/mm(2). Conclusions. With a b-value of 2000 s/mm(2) at 3T both readers differentiated clinical significant cancer from benign tissue; higher b-values can be helpful for the less experienced readers. </p>","PeriodicalId":20907,"journal":{"name":"Prostate Cancer","volume":null,"pages":null},"PeriodicalIF":2.3000,"publicationDate":"2014-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2014/868269","citationCount":"29","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Prostate Cancer","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2014/868269","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2014/2/18 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"ONCOLOGY","Score":null,"Total":0}
引用次数: 29

Abstract

Aim. To compare the diagnostic performance of diffusion weighted imaging (DWI) using b-values of 1000 s/mm(2) and 2000 s/mm(2) at 3 Tesla (T) for the evaluation of clinically significant prostate cancer. Matherials and Methods. Seventy-eight prostate cancer patients underwent a 3T MRI scan followed by radical prostatectomy. DWI was performed using b-values of 0, 1000, and 2000 s/mm(2) and qualitatively analysed by two radiologists. ADC maps were obtained at b-values of 1000 and 2000 s/mm(2) and quantitatively analyzed in consensus. Results. For diagnosis of 78 prostate cancers the accuracy of DWI for the young reader was significantly greater at b = 2000 s/mm(2) for the peripheral zone (PZ) but not for the transitional zone (TZ). For the experienced reader, DWI did not show significant differences in accuracy between b-values of 1000 and 2000 s/mm(2). The quantitative analysis in the PZ and TZ was substantially superimposable between the two b-values, albeit with a higher accuracy with a b-value of 2000 s/mm(2). Conclusions. With a b-value of 2000 s/mm(2) at 3T both readers differentiated clinical significant cancer from benign tissue; higher b-values can be helpful for the less experienced readers.

Abstract Image

Abstract Image

Abstract Image

前列腺癌DWI:临床最佳b值。
的目标。比较3tesla (T)下b值1000 s/mm(2)和2000 s/mm(2)的弥散加权成像(DWI)对具有临床意义的前列腺癌的诊断价值。材料和方法。78名前列腺癌患者接受了3T MRI扫描和根治性前列腺切除术。采用b值0、1000和2000 s/mm(2)进行DWI检查,并由两名放射科医生进行定性分析。在b值为1000和2000 s/mm(2)时获得ADC图,并进行一致的定量分析。结果。对于78种前列腺癌的诊断,年轻读者的DWI的准确性在b = 2000 s/mm(2)的外周区(PZ),而不是在过渡区(TZ)。对于经验丰富的读者,DWI在1000和2000 s/mm的b值之间没有显着差异(2)。PZ和TZ的定量分析在两个b值之间基本上是重叠的,尽管b值为2000 s/mm(2)的精度更高。结论。在3T时b值为2000 s/mm(2),这两种读卡器都能将具有临床意义的肿瘤与良性组织区分开来;较高的b值对经验不足的读者有帮助。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Prostate Cancer
Prostate Cancer ONCOLOGY-
CiteScore
2.70
自引率
0.00%
发文量
9
审稿时长
13 weeks
期刊介绍: Prostate Cancer is a peer-reviewed, Open Access journal that provides a multidisciplinary platform for scientists, surgeons, oncologists and clinicians working on prostate cancer. The journal publishes original research articles, review articles, and clinical studies related to the diagnosis, surgery, radiotherapy, drug discovery and medical management of the disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信