Region-Based Partial Volume Correction Techniques for PET Imaging: Sinogram Implementation and Robustness.

International journal of molecular imaging Pub Date : 2013-01-01 Epub Date: 2013-12-17 DOI:10.1155/2013/435959
Mike Sattarivand, Jennifer Armstrong, Gregory M Szilagyi, Maggie Kusano, Ian Poon, Curtis Caldwell
{"title":"Region-Based Partial Volume Correction Techniques for PET Imaging: Sinogram Implementation and Robustness.","authors":"Mike Sattarivand,&nbsp;Jennifer Armstrong,&nbsp;Gregory M Szilagyi,&nbsp;Maggie Kusano,&nbsp;Ian Poon,&nbsp;Curtis Caldwell","doi":"10.1155/2013/435959","DOIUrl":null,"url":null,"abstract":"<p><p>Background/Purpose. Limited spatial resolution of positron emission tomography (PET) requires partial volume correction (PVC). Region-based PVC methods are based on geometric transfer matrix implemented either in image-space (GTM) or sinogram-space (GTMo), both with similar performance. Although GTMo is slower, it more closely simulates the 3D PET image acquisition, accounts for local variations of point spread function, and can be implemented for iterative reconstructions. A recent image-based symmetric GTM (sGTM) has shown improvement in noise characteristics and robustness to misregistration over GTM. This study implements the sGTM method in sinogram space (sGTMo), validates it, and evaluates its performance. Methods. Two 3D sphere and brain digital phantoms and a physical sphere phantom were used. All four region-based PVC methods (GTM, GTMo, sGTM, and sGTMo) were implemented and their performance was evaluated. Results. All four PVC methods had similar accuracies. Both noise propagation and robustness of the sGTMo method were similar to those of sGTM method while they were better than those of GTMo method especially for smaller objects. Conclusion. The sGTMo was implemented and validated. The performance of the sGTMo in terms of noise characteristics and robustness to misregistration is similar to that of the sGTM method and improved compared to the GTMo method. </p>","PeriodicalId":89157,"journal":{"name":"International journal of molecular imaging","volume":"2013 ","pages":"435959"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2013/435959","citationCount":"5","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of molecular imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2013/435959","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/12/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

Abstract

Background/Purpose. Limited spatial resolution of positron emission tomography (PET) requires partial volume correction (PVC). Region-based PVC methods are based on geometric transfer matrix implemented either in image-space (GTM) or sinogram-space (GTMo), both with similar performance. Although GTMo is slower, it more closely simulates the 3D PET image acquisition, accounts for local variations of point spread function, and can be implemented for iterative reconstructions. A recent image-based symmetric GTM (sGTM) has shown improvement in noise characteristics and robustness to misregistration over GTM. This study implements the sGTM method in sinogram space (sGTMo), validates it, and evaluates its performance. Methods. Two 3D sphere and brain digital phantoms and a physical sphere phantom were used. All four region-based PVC methods (GTM, GTMo, sGTM, and sGTMo) were implemented and their performance was evaluated. Results. All four PVC methods had similar accuracies. Both noise propagation and robustness of the sGTMo method were similar to those of sGTM method while they were better than those of GTMo method especially for smaller objects. Conclusion. The sGTMo was implemented and validated. The performance of the sGTMo in terms of noise characteristics and robustness to misregistration is similar to that of the sGTM method and improved compared to the GTMo method.

Abstract Image

Abstract Image

Abstract Image

基于区域的PET成像部分体积校正技术:正弦图实现和鲁棒性。
背景/目的。正电子发射断层扫描(PET)的空间分辨率有限,需要进行部分体积校正(PVC)。基于区域的PVC方法基于几何传递矩阵,在图像空间(GTM)或汉字空间(GTMo)中实现,两者具有相似的性能。虽然GTMo速度较慢,但它更接近于模拟三维PET图像采集,考虑了点扩展函数的局部变化,可以实现迭代重建。最近一种基于图像的对称GTM (sGTM)在噪声特性和对错配的鲁棒性方面都比GTM有改善。本文在正弦图空间(sGTMo)中实现了sGTM方法,并对其进行了验证,并对其性能进行了评价。方法。使用了两个三维球体和大脑数字幻影和一个物理球体幻影。实现了GTM、GTMo、sGTM和sGTMo四种基于区域的PVC方法,并对其性能进行了评价。结果。所有四种PVC方法的准确度相似。sGTMo方法的噪声传播和鲁棒性与sGTM方法相似,但在较小目标上优于GTMo方法。结论。实现并验证了sGTMo。sGTMo在噪声特性和对错配的鲁棒性方面的性能与sGTM方法相似,并比GTMo方法有所提高。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书